ULTRASONIC MEASUREMENT OF FORCED DIAMETER VARIATIONS IN AN ELASTIC TUBE

被引:3
|
作者
BERRIOS, JC
PEDERSEN, PC
机构
[1] Electrical/Computer Engg. Dept., Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609, United States
关键词
COMPLIANCE; COLLAPSIBLE TUBES; CORRELATION; ELASTICITY; PULSE-ECHO; ULTRASOUND;
D O I
10.1006/uimg.1994.1008
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents an ultrasonic measurement technique to determine an elasticity parameter, called the apparent compliance, in a thin-walled tube. The apparent compliance is obtained by ultrasound pulse-echo measurement of the diameter variation in response to an externally applied time-varying pressure function. Specifically, the diameter variation is obtained by tracking the time shift of the echoes from the front and back walls of the tube using a correlation technique. This technique is named the Forced Vibration Method (FVM). This approach to compliance measurement is distinctly different from compliance measurements using the blood function as excitation function, but is closely related to the elastic imaging concept. Two experimental models, termed the rigid wall model and the leg-like model, have been developed. These models allow the amplitude and frequency of the pressure function as well as the dimensions and properties of the tube to be varied. Results for the diameter variations vs. location along the tube and frequency of external pressure function are presented for both models. (C) 1994 Academic Press, Inc.
引用
收藏
页码:124 / 142
页数:19
相关论文
共 50 条
  • [41] MEASUREMENT OF ELASTIC STIFFNESS AND DISSIPATION FOR SOLIDS AT ULTRASONIC FREQUENCIES
    MCSKIMIN, HJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1955, 27 (05): : 1009 - 1009
  • [42] ULTRASONIC INTERFEROMETER FOR THE MEASUREMENT OF THE TEMPERATURE DEPENDENCE OF ELASTIC CONSTANTS
    ESPINOLA, RP
    WATERMAN, PC
    [J]. JOURNAL OF APPLIED PHYSICS, 1958, 29 (04) : 718 - 721
  • [43] Vibration measurement of elastic tube wall downstream of stenosis
    [J]. Nippon Kikai Gakkai Ronbunshu C Hen, 600 (3030-3036):
  • [44] Measurement of respiratory flow with ultrasonic sensor using the technique of forced oscillations
    Almeida, Will
    Costa, Bruno
    Catunda, Sebastian
    Freire, Raimundo
    Santos, Francisco
    [J]. 2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 1368 - +
  • [45] Dynamic measurement of particle diameter and drag coefficient using the ultrasonic method
    Sommerlatt, Hans-Dieter
    Andruszkiewicz, Artur
    [J]. ARCHIVES OF ACOUSTICS, 2008, 33 (03) : 351 - 362
  • [47] The measurement of solid parameters of large diameter and deep shafts based on ultrasonic
    Fan Di
    Cao Maoyong
    Lv Changzhi
    Liang Huibin
    [J]. ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 720 - 723
  • [48] Continuous Measurement of Arterial Diameter Using Wearable and Flexible Ultrasonic Sensor
    Huang, Andy
    Yoshida, Masayoshi
    Ono, Yuu
    Rajan, Sreeraman
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [49] LOCAL MEASUREMENT OF FORCED CONVECTION HEAT TRANSFER IN A MICRO GLASS TUBE
    Schilder, B.
    Yu, S. C. M.
    Kasagi, N.
    Hardt, S.
    Stephan, P.
    [J]. PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, PTS A AND B, 2008, : 543 - 550
  • [50] On-line Measurement of Diameter of Hot-rolled Steel Tube
    Zhu Xueliang
    Zhao Huiying
    Tian Ailing
    Li Bin
    [J]. INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449