DIGITAL SUBTRACTION IN CONTRAST-ENHANCED MR-IMAGING OF THE POSTOPERATIVE LUMBAR SPINE

被引:16
|
作者
MURRAY, JG [1 ]
STACK, JP [1 ]
ENNIS, JT [1 ]
BEHAN, M [1 ]
机构
[1] MATER MISERICORDIAE HOSP,DEPT RADIOL,DUBLIN 7,IRELAND
关键词
D O I
10.2214/ajr.162.4.8141014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study was to evaluate the routine use of digital image subtraction as an adjunct to standard MR sequences in patients with failed lumbar spine surgery. MATERIALS AND METHODS. Unenhanced and contrast-enhanced T1-weighted MR images of 112 consecutive patients with failed back surgery were reviewed, and corresponding axial images at the level of previous surgery were digitally subtracted by using standard software. The technique was successful in 96 patients and was abandoned in 16 owing to patient motion. Two radiologists independently assessed the subtracted images for areas of enhancement not seen on T1-weighted images, and suggested a diagnosis based on a combination of the findings on standard and subtracted images. This diagnosis was compared with the original MR diagnosis, and surgical findings were sought in cases of conflict. RESULTS. Enhancement was best seen on the subtracted images in muscle fascial planes (100%), anterior epidural fibrosis (55%), spinal canal fat (31%), posterior epidural fibrosis (27%), types I and II marrow change (24%), and facet joints (17%). Subtraction improved the homogeneity of contrast enhancement, thereby improving the visualization of nerve roots lying in scar tissue (16%), and better defined the extent of epidural fibrosis, particularly when the fibrosis was contiguous with fat. The subtracted image increased diagnostic confidence in 25% of cases, but altered final diagnosis in only two patients. CONCLUSION. Although digital subtraction revealed areas of enhancement not seen on standard spin-echo MR images, it rarely altered final diagnosis and does not appear to be useful for routine imaging of patients with failed lumbar spine surgery. It might, however, be useful for increasing diagnostic confidence or as a problem-solving technique in selected patients.
引用
收藏
页码:893 / 898
页数:6
相关论文
共 50 条
  • [21] CONTRAST-ENHANCED MR-IMAGING OF INTRAHEPATIC CHOLANGIOCARCINOMA - PATHOLOGICAL CORRELATION STUDY
    MURAKAMI, T
    NAKAMURA, H
    TSUDA, K
    ISHIDA, T
    TOMODA, K
    HORI, S
    MONDEN, M
    KANAI, T
    WAKASA, K
    SAKURAI, M
    KOZUKA, T
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 165 - 170
  • [22] IRRADIATION OF THE CERVIX UTERI - VALUE OF UNENHANCED AND CONTRAST-ENHANCED MR-IMAGING
    HRICAK, H
    SWIFT, PS
    CAMPOS, Z
    QUIVEY, JM
    GILDENGORIN, V
    GORANSON, H
    RADIOLOGY, 1993, 189 (02) : 381 - 388
  • [23] EXPERIMENTAL GASTROINTESTINAL HEMORRHAGE - DETECTION WITH CONTRAST-ENHANCED MR-IMAGING AND SCINTIGRAPHY
    GUPTA, H
    WEISSLEDER, R
    BOGDANOV, AA
    BRADY, TJ
    RADIOLOGY, 1995, 196 (01) : 239 - 244
  • [24] DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF FIBROLAMELLAR HEPATOCELLULAR-CARCINOMA
    CORRIGAN, K
    SEMELKA, RC
    ABDOMINAL IMAGING, 1995, 20 (02): : 122 - 125
  • [25] MR-IMAGING IN PANCREATITIS - EVALUATION OF FINDINGS ON UNENHANCED AND CONTRAST-ENHANCED IMAGES
    SICA, GT
    CHAI, JL
    POLGER, MR
    BANKS, PA
    MILLER, FH
    RADIOLOGY, 1995, 197 : 244 - 244
  • [26] ASSESSMENT OF BREAST-CANCER RECURRENCE WITH CONTRAST-ENHANCED SUBTRACTION MR-IMAGING - PRELIMINARY-RESULTS IN 26 PATIENTS
    GILLES, R
    GUINEBRETIERE, JM
    SHAPEERO, LG
    LESNIK, A
    CONTESSO, G
    SARRAZIN, D
    MASSELOT, J
    VANEL, D
    RADIOLOGY, 1993, 188 (02) : 473 - 478
  • [27] CRANIAL POSTOPERATIVE SITE - ASSESSMENT WITH CONTRAST-ENHANCED MR IMAGING
    ELSTER, AD
    DIPERSIO, DA
    RADIOLOGY, 1990, 174 (01) : 93 - 98
  • [28] Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography
    Vakil, Parmede
    Ansari, Sameer A.
    Hurley, Michael C.
    Bhat, Himanshu
    Batjer, H. Hunt
    Bendok, Bernard R.
    Eddleman, Christopher S.
    Carroll, Timothy J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) : 249 - 258
  • [29] Blood Pool Contrast-Enhanced MR Angiography With Correlation to Digital Subtraction Angiography
    Kowalski, J.
    Knuttinen, M.
    Mar, W.
    Khiatani, V
    Golden, M.
    Xie, K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [30] Contrast-enhanced MR imaging
    Schima, W
    Mukerjee, A
    Saini, S
    CLINICAL RADIOLOGY, 1996, 51 (04) : 235 - 244