QUANTITATIVE SPECT RECONSTRUCTION OF I-123 DATA

被引:0
|
作者
GILLAND, DR
JASZCZAK, RJ
GREER, KL
COLEMAN, RE
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Many clinical and research studies in nuclear medicine require quantitation of iodine-123 (I-123) distribution for the determination of kinetics or localization. The objective of this study was to implement several reconstruction methods designed for single-photon emission computed tomography (SPECT) using I-123 and to evaluate their performance in terms of quantitative accuracy, image artifacts, and noise. The methods consisted of four attenuation and scatter compensation schemes incorporated into both the filtered backprojection/Chang (FBP) and maximum likelihood-expectation maximization (ML-EM) reconstruction algorithms. The methods were evaluated on data acquired of a phantom containing a hot sphere of I-123 activity in a lower level background I-123 distribution and nonuniform density media. For both reconstruction algorithms, nonuniform attenuation compensation combined with either scatter subtraction or Metz filtering produced images that were quantitatively accurate to within 15% of the true value. The ML-EM algorithm demonstrated quantitative accuracy comparable to FBP and smaller relative noise magnitude for all compensation schemes.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 50 条
  • [41] High energy photon correction for I-123 in SPECT studies
    de Nijs, R
    Svarer, C
    Holm, S
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S402 - S402
  • [42] A step forward in the use of SPECT imaging with I-123 MIBG
    Abdallah, Mouhamad
    Gerson, Myron C.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 16 - 18
  • [43] Prediction of improvement of cerebral perfusion with I-123 iomazenil SPECT
    Tatsuro Tsuchida
    Yoshiharu Yonekura
    Norihiro Sadato
    Norio Takahashi
    Kazutaka Yamamoto
    Yasushi Ishii
    [J]. Annals of Nuclear Medicine, 1999, 13 : 265 - 268
  • [44] SPECT IMAGING WITH I-123, PRODUCED VIA VARIOUS ROUTES
    VANWEEREN, FH
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 13 (03): : A3 - A3
  • [45] WHICH COLLIMATOR FOR SPECT WITH I-123 AND CU-67
    MACEY, DJ
    DENARDO, GL
    DENARDO, SJ
    HINES, HH
    COLE, WC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P105 - P106
  • [46] I-123 AMPHETAMINE-SPECT AND BLEULERS DISEASE - AN UPDATE
    RICCABONA, G
    BANGERL, I
    FILL, H
    HINTERHUBER, H
    [J]. ACTA MEDICA AUSTRIACA, 1987, 14 (02) : 56 - 56
  • [47] I-123 AMPHETAMINE-SPECT IN THE DIAGNOSIS OF NEUROLOGICAL DISORDERS
    BIERSACK, HJ
    KREITEN, K
    HARTMANN, A
    FRIEDRICH, G
    LINCK, HA
    WINKLER, C
    [J]. NUKLEARMEDIZINER, 1985, 8 (01): : 57 - 63
  • [48] Pearls and pitfalls of I-123 Ioflupane (DATscan) SPECT imaging
    Chaudhry, Ammar
    Gul, Maryam
    Franceschi, Dinko
    Matthews, Robert
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [49] Location of adrenal medullary pheochromocytoma by I-123 metaiodobenzylguanidine SPECT
    Nielsen, JT
    Nielsen, BV
    Rehling, M
    [J]. CLINICAL NUCLEAR MEDICINE, 1996, 21 (09) : 695 - 699
  • [50] QUANTITATIVE ASSESSMENT OF CEREBROVASCULAR RESERVE USING I-123 IMP SPECT SPLIT-DOSE METHOD
    HASHIKAWA, K
    MORIWAKI, H
    OKU, N
    OKAZAKI, Y
    UEHARA, T
    HANDA, N
    MATSUMOTO, M
    KAMADA, T
    NISHIMURA, T
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P63 - P63