Real-time measurement of cholesterol secreted by human hepatocytes using a novel microfluidic assay

被引:1
|
作者
Karnik, Sonali [1 ]
Lee, Chaeeun [1 ]
Cancino, Andrea [1 ]
Bhushan, Abhinav [1 ]
机构
[1] IIT, Dept Biomed Engn, Chicago, IL 60616 USA
来源
TECHNOLOGY | 2018年 / 6卷 / 3-4期
关键词
Hepatocytes; Tissue Chips; Real-Time Detection; Cholesterol; Drug Development;
D O I
10.1142/S2339547818500097
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of microfluidics has become widespread in recent years because of the use of lesser resources such as small size, low volume of reagents, and physiological representation of mammalian cells. One of the advantages of microfluidic-based cell culture is the ability to perfuse culture media which tends to improve cellular health and function. Although measurement of cellular function conventionally is carried out using well-plates and plate readers, these approaches are insufficient to carry out in-line analysis of perfused cell cultures because of mismatch between volumes and sensitivity. We report the development of a novel microfluidic device and assay that is carried out under perfusion, in-line to measure the cholesterol secreted from a human hepatocyte tissue-chip. The heart of the assay is the unique implementation of enzymatic chemistry that is carried out on a polystyrene bead. Using this approach, we successfully measured cholesterol secreted by the perfused human hepatocytes.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [21] Characterization of a novel Mycoplasma cynos real-time PCR assay
    Tallmadge, Rebecca L.
    Anderson, Renee
    Mitchell, Patrick K.
    Forbes, Zachary C.
    Werner, Brenda
    Gioia, Gloria
    Moroni, Paolo
    Glaser, Amy
    Thachil, Anil J.
    Goodman, Laura B.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2020, 32 (06) : 793 - 801
  • [22] Real-time monitoring of microfluidic lithography
    Pisignano, D
    Di Benedetto, F
    Persano, L
    Mele, E
    Cingolani, R
    SYNTHETIC METALS, 2005, 153 (1-3) : 325 - 328
  • [23] Live-cell Measurement of Odorant Receptor Activation Using a Real-time cAMP Assay
    Zhang, Yuetian
    Pan, Yi
    Matsunami, Hiroaki
    Zhuang, Hanyi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (128):
  • [24] Measurement of Cellular Syk Kinase Activity with A Novel Fluorescence-based Real-time Kinetic Assay
    Qian, Xiao-Dong
    Li, Min
    Clark, Jerome
    Schaefer, Erik M.
    FASEB JOURNAL, 2008, 22
  • [25] Real-time optical pH measurement in a standard microfluidic cell culture system
    Magnusson, Einar B.
    Halldorsson, Skarphedinn
    Fleming, Ronan M. T.
    Leosson, Kristjan
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (09): : 1749 - 1758
  • [26] Real-time assay for GPCRs
    Erickson, B
    ANALYTICAL CHEMISTRY, 2006, 78 (01) : 12 - 12
  • [27] Microfluidic Mobility Shift Assay for Real-Time Analysis of Peptide N-Palmitoylation
    Lanyon-Hogg, Thomas
    Patel, Neki V.
    Ritzefeld, Markus
    Boxall, Katherine J.
    Burke, Rosemary
    Blagg, Julian
    Magee, Anthony I.
    Tate, Edward W.
    SLAS DISCOVERY, 2017, 22 (04) : 418 - 424
  • [28] Detection and genotyping of human papillomavirus by real-time PCR assay
    Moreau, Frederique
    Fetouchi, Rachid
    Micalessi, Isabelle
    Brejeon, Valerie
    Bacon, Nathalie
    Jannes, Geert
    Le Pendeven, Catherine
    Lekbaby, Bouchra
    Kremsdorf, Dina
    Saint Guily, Jean Lacau
    Soussan, Patrick
    JOURNAL OF CLINICAL VIROLOGY, 2013, 56 (03) : 244 - 249
  • [29] Investigation on the Prevalence of Canine Microfilaremia in Thailand Using a Novel Microfluidic Device in Combination with Real-Time PCR
    Loymek, Sumas
    Phuakrod, Achinya
    Zaelai, Kati
    Sripumkhai, Witsaroot
    Vongjaroensanti, Prapakorn
    Wongkamchai, Sirichit
    VETERINARY SCIENCES, 2021, 8 (03) : 1 - 9
  • [30] Real-Time Monitoring of Pseudomonas Aeruginosa Concentration Using a Novel Electromagnetic Sensors Microfluidic Cell Structure
    Blakey, Richard
    Nakouti, Ismini
    Korostynska, Olga
    Mason, Alex
    Al-Shammaa, Ahmed
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (12) : 3291 - 3297