THE EFFECT OF RAPID LOCAL COOLING ON HUMAN FINGER NAILFOLD CAPILLARY BLOOD-PRESSURE AND BLOOD-CELL VELOCITY

被引:18
|
作者
HAHN, M
SHORE, AC
机构
[1] Department of Vascular Medicine, Postgraduate Medical School, University of Exeter
来源
JOURNAL OF PHYSIOLOGY-LONDON | 1994年 / 478卷 / 01期
基金
英国惠康基金;
关键词
D O I
10.1113/jphysiol.1994.sp020234
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
1. The effect of a rapid local reduction in finger temperature on finger nailfold capillary blood pressure and blood cell velocity was investigated in healthy subjects. 2. Cooling was achieved by placing the finger into an adjustable copper cylindrical finger holder, which incorporated a Peltier element within its base; thus the entire finger from just distal to the nailfold to the interphalangeal joint was cooled. The Peltier element was cooled to 8 degrees C for 5 min. 3. Finger tip temperature was reduced to 76+/-12% of its resting value during cooling (28.8+/-4.8 degrees C (mean+/-S.D.) baseline versus 22.1+/-6.4 degrees C in the fifth minute of cooling, P = 0.012); this was accompanied by a reduction in capillary blood cell velocity similar to that described previously in cooling experiments using cold air (baseline median, 671 mu m s(-1) (range, 29-4421 mu m s(-1)) versus median during cooling, 221 mu m s(-1) (range, 6.7-2579 mu m s(-1)), P = 0.012). 4. The magnitude and timing of the capillary pressure response to cooling and recovery varied between individuals. In the group as a whole, there was no significant fall in capillary pressure during cooling (basal before cooling, 16.7+/-3.7 mmHg versus minimum during cooling, 15.1+/-3.5 mmHg, P = 0.12), whereas capillary pulse pressure amplitude was reduced (basal before cooling, 5.3+/-3.1 mmHg versus minimum during cooling, 3.7+/-2.6 mmHg, P = 0.028). 5. During the recovery phase, post cooling, both capillary pressure and capillary pulse pressure amplitude were markedly elevated compared to baseline or the cooling phase. Capillary pressure increased from a minimum of 15.1+/-3.5 mmHg during cooling to a maximum of 20.9+/-4.0 mmHg in the recovery phase (P = 0.028) and capillary pulse pressure amplitude increased from a minimum of 3.7+/-2.6 mmHg during cooling to a maximum of 7.7+/-4.2 mmHg during the recovery phase, P = 0.028. 6. These data demonstrate that the Peltier-controlled finger holder provides an effective way of rapidly cooling the finger. Although cooling reduced capillary blood cell velocity, capillary pressure did not change significantly. Such findings suggest that the ratio of precapillary: postcapillary resistance is maintained during cooling. In contrast, the marked increases of capillary blood cell velocity, capillary pressure and capillary pulse pressure amplitude in the recovery phase suggests that a reduction in precapillary resistance may play a role.
引用
下载
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [11] THE RESPONSE OF BLOOD-FLOW VELOCITY IN FINGER NAILFOLD CAPILLARIES TO CONTRALATERAL COOLING
    BUTTI, P
    FAGRELL, B
    FRONEK, A
    INTAGLIETTA, M
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (01): : 19 - 27
  • [12] SKIN CAPILLARY BLOOD-CELL VELOCITY IN PREECLAMPSIA - THE EFFECT OF PLASMA EXPANSION
    ROSEN, L
    OSTERGREN, J
    FAGRELL, B
    STRANDEN, E
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1989, 8 (03): : 237 - 244
  • [13] BLOOD-CELL VELOCITY IN NAILFOLD CAPILLARIES OF PATIENTS WITH DIFFERENT KINDS OF LEUKEMIA
    FAGRELL, B
    BJORKHOLM, M
    OSTERGREN, J
    CLINICAL HEMORHEOLOGY, 1986, 6 (05): : 460 - 461
  • [14] EFFECT OF INTRAVENOUSLY ADMINISTERED PINDOLOL ON SKIN CAPILLARY BLOOD-CELL VELOCITY IN FINGERS
    FAGRELL, B
    OSTERGREN, J
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 13 : S233 - S235
  • [15] Hemodynamics in nailfold capillaries of patients with systemic scleroderma:: Synchronous measurements of capillary blood pressure and red blood cell velocity
    Hahn, M
    Heubach, T
    Steins, A
    Jünger, M
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1998, 110 (06) : 982 - 985
  • [16] Effect of prostaglandins on capillary nailfold blood pressure in healthy volunteers
    Shore, AC
    Junger, M
    Hahn, M
    JOURNAL OF PHYSIOLOGY-LONDON, 1996, 491P : P40 - P40
  • [17] CAPILLARY BLOOD-CELL VELOCITY - NORMAL VALUES AND PROVOCATION TESTS
    OSTERGREN, J
    FAGRELL, B
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (3-4): : 492 - 492
  • [18] CAPILLARY RED BLOOD-CELL VELOCITY IN SKELETAL-MUSCLE
    GROSS, JF
    ARFORS, KE
    INTAGLIE.M
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 337 - 337
  • [19] CAPILLARY BLOOD-CELL VELOCITY IS REDUCED IN FEVER WITHOUT HYPOTENSION
    WEINBERG, JR
    BOYLE, P
    THOMAS, K
    MURPHY, K
    TOOKE, JE
    GUZ, A
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1991, 10 (01): : 13 - 19
  • [20] COMPUTERIZED DATA-ANALYSIS OF CAPILLARY BLOOD-CELL VELOCITY
    FAGRELL, B
    ERIKSSON, SE
    MALMSTROM, S
    SJOLUND, A
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1988, 7 (03): : 276 - 276