COMPARISON OF (99M)TECHNETIUM HEXAMETHYLPROPYLENE-AMINE OXIME LABELED LEUKOCYTE WITH (111)-INDIUM TROPOLONATE LABELED GRANULOCYTE SCANNING AND ULTRASOUND IN THE DIAGNOSIS OF INTRAABDOMINAL ABSCESS

被引:24
|
作者
WELDON, MJ
JOSEPH, AEA
FRENCH, A
SAVERYMUTTU, SH
MAXWELL, JD
机构
[1] ST GEORGE HOSP, SCH MED, DEPT RADIOL, LONDON SW17 0RE, ENGLAND
[2] ST GEORGE HOSP, SCH MED, DEPT RADIOPHARM, LONDON SW17 0RE, ENGLAND
关键词
INTRAABDOMINAL ABSCESS; (99M)-TECHNETIUM; (111)-INDIUM; ULTRASOUND; INFLAMMATORY BOWEL DISEASE; CROHNS DISEASE;
D O I
10.1136/gut.37.4.557
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Fifty patients with suspected intraabdominal abscess were investigated prospectively with ultrasound and with Tc-99m-hexamethylpropylene-amine oxime (HMPAO) isotope labelled mixed leucocytes, using (111)-In tropolonate granulocyte scanning as the reference standard. Twenty five patients had inflammatory bowel disease (three were postoperative): 21 of these had Crohn's disease and four had ulcerative colitis. The remainder comprised nine with postoperative fever and 16 with fever and abdominal pain. An abscess was diagnosed when focal activity on serial (111)-In tropolonate and (99m)-Tc-HMPOA images at one, three, and 24 hours resulted in activity at least equal to liver activity at 24 hours. Thirteen abscesses were diagnosed using each type of white cell scanning, resulting in 100% sensitivity for (99m)-Tc-HMPAO compared with (111)-In tropolonate. Bowel inflammation was easily distinguished from abscess on serial images. Eight of these 13 abscesses were detected by ultrasound. Altogether 17 abscesses were found. Ultrasound detected 12, including four liver abscesses which were not purulent and had not been detected by white cell scanning. Ultrasound had a sensitivity of 71% (12 of 17) and a specificity of 87% (33 of 38) using all confirmed abscesses as the reference standard. White cell scanning showed a sensitivity of 76% (13 of 17: as a result of the four non-purulent liver abscesses) and a specificity of 100%. (99m)-Tc-HIMPAO scanning is as accurate as (111)-In tropolonate scanning, and has several advantages including simplicity, availability, superior image quality, and reduced radiation dose. Both methods are more sensitive and specific than ultrasound for intra-abdominal abscess detection but ultrasound is advisable if a neutrophil infiltrate is not suspected.
引用
收藏
页码:557 / 564
页数:8
相关论文
共 23 条
  • [21] Technetium-99m hexamethyl propylene amine oxime-labeled leukocyte scintigraphy at three different times in active ulcerative colitis: comparison with colonoscopy and clinico-biochemical parameters in the assessment of disease extension and severity
    Funda Aydın
    Dinç Dinçer
    Fırat Güngör
    Adil Boz
    Serdar Akça
    Akın Yıldız
    Özgür Tosun
    Binnur Karayalçın
    Annals of Nuclear Medicine, 2008, 22
  • [22] GRANULOCYTE-SPECIFIC MONOCLONAL-ANTIBODY TECHNETIUM-99M-BW-250/183 AND IN-111 OXINE-LABELED LEUKOCYTE SCINTIGRAPHY IN INFLAMMATORY BOWEL-DISEASE
    SEGARRA, I
    ROCA, M
    BALIELLAS, C
    VILAR, L
    RICART, Y
    MORA, J
    PUCHAL, R
    MARTINCOMIN, J
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (09): : 715 - 719
  • [23] Technetium-99m hexamethyl propylene amine oxime-labeled leukocyte scintigraphy at three different times in active ulcerative colitis:: comparison with colonoscopy and clinico-biochemical parameters in the assessment of disease extension and severity
    Aydin, Funda
    Dincer, Dinc
    Guengoer, Firat
    Boz, Adil
    Akca, Serdar
    Yildiz, Akin
    Tosun, Oezguer
    Karayalcin, Binnur
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (05) : 371 - 377