A NEW ONLINE COPRECIPITATION PRECONCENTRATION TECHNIQUE FOR TRACE-METAL ANALYSIS BY ICP-AES

被引:0
|
作者
PARK, KH
PAK, YN
机构
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In a stream of water sample, trace metal ions are quantitatively coprecipitated with Indium hydroxide and filtered. The filtered precipitate is continuously dissolved in 3 M nitric acid and introduced to ICP directly. The lead, cadmium, and copper are concentrated more than 10-fold and determined with ICP-AES at a sampling frequency of 10/hour. The detection limits are 2.89, 1.43, 0.52 ppb for lead, cadmium, and copper respectively. Recoveries of lead, cadmium, and copper are 98.7, 94.3, and 104.5% respectively. The RSD values for three elements are about 3-5% currently.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 50 条
  • [31] Multielement determination of trace elements in coastal seawater by ICP-MS and ICP-AES after aluminum coprecipitation associated with magnesium
    Sawatari, H
    Hayashi, T
    Fujimori, E
    Hirose, A
    Haraguchi, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1996, 69 (07) : 1925 - 1931
  • [32] A VERSATILE TECHNIQUE FOR MULTIELEMENT ICP-AES ANALYSIS OF GEOLOGICAL SAMPLES
    BRENNER, IB
    LANG, Y
    LEMARCHAND, A
    GROSDAILLON, P
    AMERICAN LABORATORY, 1987, 19 (10) : 17 - &
  • [33] ICP-AES analysis of trace elements in human hair of chronic hepatitis
    Zhou, XY
    Cheng, FL
    Nin, MX
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (03) : 361 - 363
  • [34] Forensic discrimination of arsenous acid by the analysis of trace impurities with ICP-AES
    Suzuki, Y
    Kasamatsu, M
    Suzuki, S
    Ohashi, K
    Kawase, A
    BUNSEKI KAGAKU, 2001, 50 (05) : 335 - 339
  • [35] Study on the Analysis of Main and Trace Elements in Phosphate Rock by ICP-AES
    Li, Dong
    Zhao, Jun
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2001, 21 (02):
  • [36] ANALYSIS OF TANTALUM BY ICP-AES INVOLVING TRACE-MATRIX SEPARATION
    KRIVAN, V
    HAUSBECK, R
    WILHARTITZ, P
    KRISMER, R
    ORTNER, HM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 341 (09): : 550 - 554
  • [37] Study on the analysis of main and trace elements in phosphate rock by ICP-AES
    Li, D
    Zhao, J
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (02) : 233 - 234
  • [38] MULTIELEMENTAL ANALYSIS IN BIOLOGICAL SAMPLES BY ONLINE PRECONCENTRATION ON 8-HYDROXYQUINOLINE-CELLULOSE MICROCOLUMN COUPLED TO SIMULTANEOUS ICP-AES
    SCHRAMEL, P
    XU, LG
    KNAPP, G
    MICHAELIS, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (8-9): : 600 - 606
  • [39] USE OF INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROSCOPY (ICP-AES) IN SCREENING FOR TRACE-METAL EXPOSURES IN AN INDUSTRIAL-POPULATION
    FRANZBLAU, A
    ROSENSTOCK, L
    EATON, DL
    ENVIRONMENTAL RESEARCH, 1988, 46 (01) : 15 - 24
  • [40] Black cohosh: Heavy metal analysis via ICP-AES
    Minnick, Andrew J.
    Biser, Peggy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241