ION MOBILITY SPECTROMETRY AFTER CHROMATOGRAPHY - ACCOMPLISHMENTS, GOALS, CHALLENGES

被引:6
|
作者
HILL, HH
EATHERTON, RL
机构
[1] Washington State Univ, United States
关键词
Organic Compounds--Chromatographic Analysis - Trace Analysis;
D O I
10.6028/jres.093.103
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors designed and constructed an ion mobility spectrometer that was specifically suited for the detection of trace organics after separation by high resolution gas chromatography. Using a unique unidirectional flow design, problems associated with long residence times in the spectrometer were eliminated. The high resolution gas chromatograph insured the purity of standards and enabled the introduction of sufficiently small quantities of compounds. Microprocessor-controlled operation of the ion gates in the drift tube permitted both selective and nonselective detection of chromatographic effluent and the Fourier transform method of operation enabled spectra from rapidly eluting capillary chromatographic peaks to be captured 'on the fly'. It was also found that the linear range of the detector could be extended by the use of a photoionization source. Current goals and future challenges are discussed.
引用
下载
收藏
页码:425 / 426
页数:2
相关论文
共 50 条
  • [41] Ion mobility spectrometry and mass spectrometry coupled to gas chromatography for analysis of microbial contaminated cosmetic creams
    Garcia-Nicolas, Maria
    Arroyo-Manzanares, Natalia
    de Dios Hernandez, Juan
    Guillen, Isidro
    Vizcaino, Pascuala
    Sanchez-Rubio, Marta
    Lopez-Garcia, Ignacio
    Hernandez-Cordoba, Manuel
    Vinas, Pilar
    ANALYTICA CHIMICA ACTA, 2020, 1128 : 52 - 61
  • [42] Evaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection
    Matz, LM
    Dion, HM
    Hill, HH
    JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) : 59 - 68
  • [43] Ion mobility spectrometry combined with ultra performance liquid chromatography/mass spectrometry for metabolic phenotyping of urine: Effects of column length, gradient duration and ion mobility spectrometry on metabolite detection
    Rainville, Paul D.
    Wilson, Ian D.
    Nicholson, Jeremy K.
    Issacs, Giorgis
    Mullin, Lauren
    Langridge, James I.
    Plumb, Robert S.
    ANALYTICA CHIMICA ACTA, 2017, 982 : 1 - 8
  • [44] Ion mobility spectrometry rediscovered
    Cottingham, K
    ANALYTICAL CHEMISTRY, 2003, 75 (19) : 435A - 439A
  • [45] Inverse Ion Mobility Spectrometry
    Tabrizchi, Mahmoud
    Jazan, Elham
    ANALYTICAL CHEMISTRY, 2010, 82 (02) : 746 - 750
  • [46] Trapped ion mobility spectrometry
    Ridgeway, Mark
    Park, Melvin
    Meier, Jacob
    Silveira, Joshua
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [47] Ion Mobility Mass Spectrometry
    Barran, Perdita
    Ruotolo, Brandon
    ANALYST, 2015, 14 (20) : 6772 - 6774
  • [48] DEVELOPMENTS IN ION MOBILITY SPECTROMETRY
    SPANGLER, GE
    CAMPBELL, DN
    VORA, KN
    CARRICO, JP
    ISA TRANSACTIONS, 1984, 23 (01) : 17 - 28
  • [49] Correlation ion mobility spectrometry
    Davis, Austen L.
    Liu, Wenjie
    Siems, William F.
    Clowers, Brian H.
    ANALYST, 2017, 142 (02) : 292 - 301
  • [50] Progress in ion mobility spectrometry
    Feng, X
    Wang, HL
    Guan, YF
    PROGRESS IN CHEMISTRY, 2005, 17 (03) : 514 - 522