ION MOBILITY SPECTROMETRY AFTER CHROMATOGRAPHY - ACCOMPLISHMENTS, GOALS, CHALLENGES

被引:6
|
作者
HILL, HH
EATHERTON, RL
机构
[1] Washington State Univ, United States
关键词
Organic Compounds--Chromatographic Analysis - Trace Analysis;
D O I
10.6028/jres.093.103
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors designed and constructed an ion mobility spectrometer that was specifically suited for the detection of trace organics after separation by high resolution gas chromatography. Using a unique unidirectional flow design, problems associated with long residence times in the spectrometer were eliminated. The high resolution gas chromatograph insured the purity of standards and enabled the introduction of sufficiently small quantities of compounds. Microprocessor-controlled operation of the ion gates in the drift tube permitted both selective and nonselective detection of chromatographic effluent and the Fourier transform method of operation enabled spectra from rapidly eluting capillary chromatographic peaks to be captured 'on the fly'. It was also found that the linear range of the detector could be extended by the use of a photoionization source. Current goals and future challenges are discussed.
引用
下载
收藏
页码:425 / 426
页数:2
相关论文
共 50 条
  • [1] ION MOBILITY SPECTROMETRY AFTER SUPERCRITICAL FLUID CHROMATOGRAPHY
    ROKUSHIKA, S
    HATANO, H
    HILL, HH
    ANALYTICAL CHEMISTRY, 1987, 59 (01) : 8 - 12
  • [2] ION MOBILITY SPECTROMETRY AFTER SUPERCRITICAL FLUID CHROMATOGRAPHY.
    Rokushika, Souji
    Hatano, Hiroyuki
    Hill Jr., Herbert H.
    1600, (59):
  • [3] ION MOBILITY SPECTROMETRY OF UNDERIVATIZED DRUGS AFTER SUPERCRITICAL FLUID CHROMATOGRAPHY
    HILL, HH
    EATHERTON, RL
    MORRISSEY, MA
    SIEMS, WF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 31 - ANYL
  • [4] THE MOLECVUE PROJECT - GOALS, ACCOMPLISHMENTS AND CHALLENGES
    ANDERSON, WP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 418 - CHED
  • [5] Ion mobility spectrometry detection for gas chromatography
    Kanu, Abu B.
    Hill, Herbert H., Jr.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) : 12 - 27
  • [6] Coupling Gas Chromatography with Ion Mobility Spectrometry
    Witkiewicz, Zygfryd
    Perycz, Urszula
    Maziejuk, Miroslaw
    Puton, Jaroslaw
    LCGC EUROPE, 2016, 29 (06) : 294 - 303
  • [7] Ophthalmic Pathology: History, Accomplishments, Challenges, and Goals
    Grossniklaus, Hans E.
    OPHTHALMOLOGY, 2015, 122 (08) : 1539 - 1542
  • [8] FOURIER TRANSFORM ION MOBILITY SPECTROMETRY OF BARBITURATES AFTER CAPILLARY GAS CHROMATOGRAPHY.
    Eatherton, R.L.
    Siems, W.F.
    Hill Jr., H.H.
    HRC & CC. Journal of high resolution chromatography & chromatography communications, 1986, 9 (01) : 44 - 48
  • [9] MEMBRANE INLET FOR ION MOBILITY SPECTROMETRY (PLASMA CHROMATOGRAPHY)
    SPANGLER, GE
    CARRICO, JP
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 52 (2-3): : 267 - 287
  • [10] SYMPOSIUM ON ACCURACY IN TRACE ANALYSIS - ACCOMPLISHMENTS, GOALS, CHALLENGES
    VELAPOLDI, RA
    DURST, RA
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1988, 7 (02) : 49 - &