THE REEVALUATION OF MIBI AS THE LIGAND OF Tc-99m-MIBI RADIOPHARMACEUTICAL FOR MYOCARDIAL IMAGING

被引:2
|
作者
Nurlaila, Z. [1 ]
Daruwati, I. [1 ]
机构
[1] Natl Nucl Energy Agcy BATAN, Ctr Nucl Technol Mat & Radiometry, Tamansari 71, Bandung 40132, Indonesia
关键词
Radiopharmaceutical; MIBI; Tc-99m; Myocardial imaging;
D O I
10.17146/aij.2008.88
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Methoxy isobutyl isonitrile labelled with technetium-99m (Tc-99m) radionuclide can be used for the evaluation of acute myocardial infarction. The Tc-99m-MIBI radiopharmaceutical is available in the lyophilized-kit, which is separately packed with its radionuclide. Recently, in CNTMR-BATAN Bandung, Tc-99m-MIBI radiopharmaceutical was prepared using MIBI ligand synthesized in 1996 as lyophilized-kits having the radiochemical purity less than 90 % and not accumulated in the myocardium. It could be caused by several factors, among others were technical preparation of lyophilized dry-kit and the quality of MIBI; therefore the reevaluation of the ligand for the quality improvement was needed. Firstly, MIBI ligand was recristallized. It was found that MIBI as [Cu(MIBI)(4)] BF4 salt was a glassy solid with the melting point of 98 -99 degrees C. The infra red analysis showed the presence of spectra vibration at 1085, 1180 cm(-1) and 2180, 2220 cm(-1) for -OCH3 and N=C groups, respectively. The preparation of Tc-99m-MIBI was performed by adding Tc-99m radionuclide into new MIBI liquid-kit, then boiled in water bath for minimum period of 10 minutes. The radiochemical purity of Tc-99m-MIBI was analysed by thin layer chromatographic method using absolute ethanol as a mobile phase. The pre-clinical evaluation was observed in Wistar rat and clinical studies were performed in volunter using gamma camera. It is revealed that the radiochemical purity of more than 90 % i.e. 96.83 +/- 1.43 % was still stable until 24 hours storage at room temperature. The stability studies of Tc-99m-MIBI in human blood plasma showed that in 6 hours, the radiochemical purity was decreased to 90.89 +/- 2.90 %. Clinical application of Tc-99m-MIBI with tomography techniques using gamma camera showed the distinct accumulation of radioactivity in the heart.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [41] Tc-99m-MIBI SPECT/CT imaging to diagnose secondary hyperparathyroidism after parathyroid forearm transplantation
    Xu, Zhenchun
    Zheng, Chenxi
    Rao, Maohua
    Xiong, Yalan
    Tian, Yan
    Yuan, Gengbiao
    HEMODIALYSIS INTERNATIONAL, 2024, 28 (03) : 382 - 386
  • [42] Comparative uptake of Tc-99m-mibi and Tc-99m-N-acetylcysteine in an experimental tumor model.
    Faintuch, BL
    Almeida, MATM
    Muramoto, E
    Buchpiegel, C
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 221P - 221P
  • [43] Tc-99m-MIBI scintigraphy for recurrent hyperparathyroidism after total parathyroidectomy with autograft
    Kazuo Itoh
    Reiki Ishizuka
    Annals of Nuclear Medicine, 2003, 17 : 315 - 320
  • [44] Detection of minimal residual disease in acute leukemia by Tc-99m-MIBI femoral marrow imaging.
    Wakasugi, S
    Ota, K
    Teshima, H
    Nakamura, H
    Tatumi, N
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 211P - 211P
  • [45] A case report of a functioning mediastinal parathyroid cyst with no Tc-99m-MIBI uptake
    Uchida, Naotaka
    Yoshida, Manabu
    Matsui, Yasuki
    Notsu, Takeshi
    INTERNATIONAL JOURNAL OF SURGERY OPEN, 2018, 12 : 5 - 8
  • [46] ABCB1 gene, but not gender may influence Tc-99m-2-methoxyisobutylisonitril (Tc-99m-MIBI) imaging findings
    Dizdarevic, S.
    Aplin, M.
    Newport, M. J.
    Ryan, N.
    Holt, S. G.
    Goubet, S.
    Goldberg, L.
    Miles, K. A.
    Peters, A. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S128 - S128
  • [47] Tc-99m-MIBI scintigraphy for recurrent hyperparathyroidism after total parathyroidectomy with autograft
    Itoh, K
    Ishizuka, R
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (04) : 315 - 320
  • [48] Tc-99m-MIBI prone scintimammography in patients with high and intermediate risk mammography
    Scopinaro, F
    Ierardi, M
    Porfiri, LM
    Tiberio, NS
    DeVincentis, G
    Mezi, S
    Cannas, P
    Gigliotti, T
    Marzetti, L
    ANTICANCER RESEARCH, 1997, 17 (3B) : 1635 - 1638
  • [49] CORONARY-ARTERY STENOSIS AND OCCLUSION - VALUE OF TC-99M-MIBI SPECT
    GYONGYOSI, M
    MAUL, FD
    STANDKE, R
    KLEPZIG, H
    KALTENBACH, M
    HOR, G
    NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (08) : 593 - 603
  • [50] SYNTHESIS, CHARACTERIZATION AND BIODISTRIBUTION OF A NEW TC-99M COMPLEX WITH TRIMETHYLSILYLMETHYLISONITRILE - COMPARISON WITH TC-99M-TBI AND TC-99M-MIBI
    BOUQUILLON, S
    COULAIS, Y
    DARTIGUENAVE, M
    TAFANI, JAM
    GUIRAUD, R
    NUCLEAR MEDICINE AND BIOLOGY, 1995, 22 (05): : 585 - 588