A DIFFERENTIAL ABSORPTION SPECTROMETER FOR DETERMINING FLASH X-RAY-SPECTRA FROM 10 KEV TO 2000 KEV

被引:13
|
作者
CARLSON, GA
LORENCE, LJ
机构
[1] Sandia Natl Lab, Albuquerque, NM,, USA
关键词
Computer Software - Spectroscopy; Absorption; -; Thermoluminescence;
D O I
10.1109/23.25448
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A differential absorption spectrometer was developed and used on various bremsstrahlung sources (Pelletron, Saturn, and SPEED) with endpoint energies from 150 to 2000 keV. Spectral data were unfolded using response functions generated by TIGER and CEPXS/ONETRAN. Unfolded spectra are qualitatively in agreement with predicted spectra for steady-state bremsstrahlung sources from 150 keV and 900 keV. Applications and limitations of the diagnostic are discussed, and modifications and simplifications are suggested.
引用
收藏
页码:1255 / 1259
页数:5
相关论文
共 50 条
  • [31] DETERMINING VALENCY STATES AND COORDINATION FROM THE LAST EMISSION-LINES IN X-RAY-SPECTRA
    OVSYANNIKOVA, IA
    KUPRIYANOVA, TA
    GOLDENBERG, GI
    INDUSTRIAL LABORATORY, 1987, 53 (06): : 529 - 532
  • [32] Dispersive x-ray absorption spectroscopy with gratings above 2 keV
    Heimann, PA
    Koike, M
    Padmore, HA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):
  • [33] DETERMINATION OF X-RAY-SPECTRA FROM MEASUREMENTS OF ATTENUATION
    DANCE, DR
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 860 - 860
  • [34] ELEMENT CONCENTRATIONS FROM OVERLAPPING X-RAY-SPECTRA
    MA, XP
    PALMER, GR
    MACARTHUR, JD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 22 (1-3): : 49 - 54
  • [35] Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV
    Saat, Ahmad
    Hamzah, Zaini
    Yusop, Mohammad Fariz
    Zainal, Muhd Amiruddin
    PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 39 - +
  • [36] An X-ray Raman spectrometer for EXAFS studies on minerals: bent Laue spectrometer with 20 keV X-rays
    Hiraoka, N.
    Fukui, H.
    Tanida, H.
    Toyokawa, H.
    Cai, Y. Q.
    Tsuei, K. D.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 266 - 271
  • [38] AUGER-ELECTRON AND X-RAY PRODUCTION IN 50-KEV TO 2000-KEV NE+NE COLLISIONS
    STOLTERFOHT, N
    SCHNEIDER, D
    BURCH, D
    AAGAARD, B
    BOVING, E
    FASTRUP, B
    PHYSICAL REVIEW A, 1975, 12 (04): : 1313 - 1329
  • [39] ORIGIN OF THE SATELLITE L-GAMMA-10 IN X-RAY-SPECTRA
    NIGAM, AN
    SONI, SN
    CANADIAN JOURNAL OF PHYSICS, 1985, 63 (11) : 1418 - 1420
  • [40] USING A 10-KEV X-RAY SOURCE FOR HARDNESS ASSURANCE
    FLEETWOOD, DM
    BEEGLE, RW
    SEXTON, FW
    WINOKUR, PS
    MILLER, SL
    TREECE, RK
    SCHWANK, JR
    JONES, RV
    MCWHORTER, PJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (06) : 1330 - 1336