A DIFFERENTIAL ABSORPTION SPECTROMETER FOR DETERMINING FLASH X-RAY-SPECTRA FROM 10 KEV TO 2000 KEV

被引:13
|
作者
CARLSON, GA
LORENCE, LJ
机构
[1] Sandia Natl Lab, Albuquerque, NM,, USA
关键词
Computer Software - Spectroscopy; Absorption; -; Thermoluminescence;
D O I
10.1109/23.25448
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A differential absorption spectrometer was developed and used on various bremsstrahlung sources (Pelletron, Saturn, and SPEED) with endpoint energies from 150 to 2000 keV. Spectral data were unfolded using response functions generated by TIGER and CEPXS/ONETRAN. Unfolded spectra are qualitatively in agreement with predicted spectra for steady-state bremsstrahlung sources from 150 keV and 900 keV. Applications and limitations of the diagnostic are discussed, and modifications and simplifications are suggested.
引用
收藏
页码:1255 / 1259
页数:5
相关论文
共 50 条
  • [1] A DIFFERENTIAL ABSORPTION SPECTROMETER FOR DETERMINING FLASH X-RAY-SPECTRA
    CARLSON, GA
    FEHL, DL
    LORENCE, LJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (02): : 264 - 274
  • [2] MEASUREMENTS OF CHARACTERISTIC AND CONTINUOUS X-RAY-SPECTRA PRODUCED BY MONOENERGETIC ELECTRONS IN ENERGY RANGE 10 TO 30 KEV
    LIUZZI, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01): : 118 - &
  • [3] INTERPRETATION OF LASER-PRODUCED AU AND W X-RAY-SPECTRA IN THE 3 KEV RANGE
    ZIGLER, A
    KLAPISCH, M
    MANDELBAUM, P
    PHYSICS LETTERS A, 1986, 117 (01) : 31 - 35
  • [4] Spectra of the 1/4 keV X-ray diffuse background from the diffuse X-ray spectrometer experiment
    Sanders, WT
    Edgar, RJ
    Kraushaar, WL
    McCammon, D
    Morgenthaler, JP
    ASTROPHYSICAL JOURNAL, 2001, 554 (02): : 694 - 709
  • [5] SUB-KEV, SUB-NANOSECOND MEASUREMENTS OF X-RAY-SPECTRA FROM LASER-PRODUCED PLASMAS
    KORNBLUM, HN
    KOPPEL, LN
    SLIVINSKY, VW
    GLAROS, SS
    AHLSTROM, HG
    LARSEN, JT
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1195 - 1195
  • [6] High resolution spectrometer for extended x-ray absorption fine structure measurements in the 6 keV to 15 keV energy range
    Seely, J. F.
    Hudson, L. T.
    Henins, Albert
    Feldman, U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [7] LUMINOSITY DEPENDENCE OF THE HARDNESS OF THE 13-80 KEV X-RAY-SPECTRA OF LOW-MASS X-RAY BINARIES
    VANPARADIJS, J
    VANDERKLIS, M
    ASTRONOMY & ASTROPHYSICS, 1994, 281 (01) : L17 - L20
  • [8] DESIGN OF AN OPTIMAL ROSS FILTER SYSTEM FOR X-RAY-SPECTRA MEASUREMENTS IN THE RANGE OF 8.98-88-KEV
    KHUTORETSKY, IV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 773 - 775
  • [9] COMPARISON OF DETECTORS USED IN MEASUREMENT OF 10 TO 300 KEV X-RAY SPECTRA
    ISRAEL, HI
    LIER, DW
    STORM, E
    NUCLEAR INSTRUMENTS & METHODS, 1971, 91 (02): : 141 - +
  • [10] COMPARISON OF MEASURED PRIMARY X-RAY-SPECTRA FROM MOLYBDENUM AND TUNGSTEN TARGETS DUE TO BOMBARDMENT BY MONOENERGETIC ELECTRONS IN ENERGY-RANGE 10 TO 30 KEV
    LIUZZI, A
    CHERVENAK, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (02): : 258 - 258