RADIATION-DOSE TO POSITRON EMISSION TOMOGRAPHY TECHNOLOGISTS DURING QUANTITATIVE VERSUS QUALITATIVE STUDIES

被引:0
|
作者
MCCORMICK, VA [1 ]
MIKLOS, JA [1 ]
机构
[1] UNIV MICHIGAN,SCH PUBL HLTH,DEPT RADIOL HLTH,ANN ARBOR,MI 48109
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography technologists were monitored with thermoluminescent dosimeters (TLDs) during qualitative and quantitative studies. Doses to technologists during specific tasks were also measured. The technologists received at least twice as much radiation during the quantitative as the qualitative studies. The average dose per study for qualitative studies was 0.017 mSv (1.7 mrem) shallow and 0.014 mSv (1.4 mrem) deep. The average dose per study for the quantitative studies was 0.05 mSv (5 mrem) shallow and 0.04 mSv (4 mrem) deep. The average dose per study was based on the TLD dose accumulated over studies conducted over four 2-mo and one 1-mo intervals. The dose incurred by the technologists each time they drew a radioactive dose was 0.002 mSv (0.2 mrem) shallow and 0.001 mSv (0.1 mrem) deep. The doses received during injection were 0.014 mSv (1.4 mrem) shallow and 0.007 mSv (0.7 mrem) deep. Doses received during blood sampling were 0.016 mSv (1.6 mrem) shallow and 0.014 mSv (1.4 mrem) deep. During quantitative studies, the technologist received a much greater dose than during its qualitative counterpart due to the blood sampling process and increased time in the room with the radioactive patient.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 50 条
  • [31] QUANTITATIVE INVIVO AUTORADIOGRAPHY WITH POSITRON EMISSION TOMOGRAPHY
    RAICHLE, ME
    BRAIN RESEARCH REVIEWS, 1979, 1 (01) : 47 - 68
  • [32] Quantitative positron emission tomography in brain research
    Heurling, Kerstin
    Leuzy, Antoine
    Jonasson, My
    Frick, Andreas
    Zimmer, Eduardo R.
    Nordberg, Agneta
    Lubberink, Mark
    BRAIN RESEARCH, 2017, 1670 : 220 - 234
  • [33] Statistical approaches in quantitative positron emission tomography
    Leahy, RM
    Qi, JY
    STATISTICS AND COMPUTING, 2000, 10 (02) : 147 - 165
  • [34] POSITRON EMISSION TOMOGRAPHY STUDIES IN PARKINSONISM
    EIDELBERG, D
    NEUROLOGIC CLINICS, 1992, 10 (02) : 421 - 433
  • [35] Statistical approaches in quantitative positron emission tomography
    Richard M. Leahy
    Jinyi Qi
    Statistics and Computing, 2000, 10 : 147 - 165
  • [36] Positron emission tomography receptor studies
    Duncan, JS
    EPILEPSIA, 1997, 38 : 48 - 51
  • [37] Positron emission tomography studies of sleep
    Maquet, P
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 1995, 25 (06): : 342 - 350
  • [38] A positron emission tomography/computed tomography (PET/CT) acquisition protocol for CT radiation dose optimization
    Wu, TH
    Chu, TC
    Huang, YH
    Chen, LK
    Mok, SP
    Lee, JK
    Yeu-Sheng, T
    Lee, JJS
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (04) : 323 - 330
  • [39] Positron emission tomography studies in headache
    Diener, HC
    HEADACHE, 1997, 37 (10): : 622 - 625
  • [40] Factors affecting radiation exposure dose in nursing staff during 18F-fluorodeoxyglucose positron emission tomography/computed tomography
    Ito, Kimiteru
    Suzuki, Maid
    Yamazaki, Aino
    Suzuki, Yoshiko
    Yokokawa, Naoki
    Oosawa, Tatsufumi
    Tokumaru, Aya M.
    JOURNAL OF OCCUPATIONAL HEALTH, 2015, 57 (04) : 316 - 323