RADIATION-DOSE TO POSITRON EMISSION TOMOGRAPHY TECHNOLOGISTS DURING QUANTITATIVE VERSUS QUALITATIVE STUDIES

被引:0
|
作者
MCCORMICK, VA [1 ]
MIKLOS, JA [1 ]
机构
[1] UNIV MICHIGAN,SCH PUBL HLTH,DEPT RADIOL HLTH,ANN ARBOR,MI 48109
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography technologists were monitored with thermoluminescent dosimeters (TLDs) during qualitative and quantitative studies. Doses to technologists during specific tasks were also measured. The technologists received at least twice as much radiation during the quantitative as the qualitative studies. The average dose per study for qualitative studies was 0.017 mSv (1.7 mrem) shallow and 0.014 mSv (1.4 mrem) deep. The average dose per study for the quantitative studies was 0.05 mSv (5 mrem) shallow and 0.04 mSv (4 mrem) deep. The average dose per study was based on the TLD dose accumulated over studies conducted over four 2-mo and one 1-mo intervals. The dose incurred by the technologists each time they drew a radioactive dose was 0.002 mSv (0.2 mrem) shallow and 0.001 mSv (0.1 mrem) deep. The doses received during injection were 0.014 mSv (1.4 mrem) shallow and 0.007 mSv (0.7 mrem) deep. Doses received during blood sampling were 0.016 mSv (1.6 mrem) shallow and 0.014 mSv (1.4 mrem) deep. During quantitative studies, the technologist received a much greater dose than during its qualitative counterpart due to the blood sampling process and increased time in the room with the radioactive patient.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 50 条
  • [1] MEASUREMENT OF RADIATION-DOSE TO THE THYROID USING POSITRON EMISSION TOMOGRAPHY
    OTT, RJ
    BATTY, V
    WEBB, S
    FLOWER, MA
    LEACH, MO
    CLACK, R
    MARSDEN, PK
    MCCREADY, VR
    BATEMAN, JE
    SHARMA, H
    SMITH, A
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (711): : 245 - 251
  • [2] Dose absorbed by technologists in positron emission tomography procedures with FDG
    Amaral, Ademir
    Itie, Christian
    Bok, Bernard
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2007, 50 : 129 - 134
  • [3] QUALITATIVE VERSUS QUANTITATIVE INTERPRETATION OF POSITRON EMISSION TOMOGRAPHY IN ACUTE STROKE
    GZESH, D
    GOLDSTEIN, S
    ALVES, W
    JAMIESON, D
    KUSHNER, M
    CHAWLUK, J
    ALAVI, A
    REIVICH, M
    ANNALS OF NEUROLOGY, 1990, 28 (02) : 257 - 257
  • [4] Radiation dose rates from patients undergoing positron emission tomography: implications for technologists and waiting areas
    N. A. Benatar
    B. F. Cronin
    M. J. O’Doherty
    European Journal of Nuclear Medicine, 2000, 27 : 583 - 589
  • [6] RADIATION-DOSE BY MEDICAL AND OCCUPATIONAL EXPOSURE IN RADIOLOGIC TECHNOLOGISTS
    TSUCHIYA, T
    NORIMURA, T
    JOURNAL OF RADIATION RESEARCH, 1984, 25 (01) : 5 - 5
  • [7] POSITRON EMISSION TOMOGRAPHY, POSSIBILITIES IN QUANTITATIVE STUDIES
    SOUSSALINE, F
    PLUMMER, D
    TODDPOKROPEK, AE
    HOULE, S
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1980, 7 (03): : 233 - 236
  • [8] Radiation Dose Modulation of Computed Tomography Component in Positron Emission Tomography/Computed Tomography
    Inoue, Yusuke
    SEMINARS IN NUCLEAR MEDICINE, 2022, 52 (02) : 157 - 166
  • [9] RADIATION-DOSE DISTRIBUTION IN TEMPORAL BONE TOMOGRAPHY
    DAHLIN, H
    NYLEN, O
    WILBRAND, H
    ACTA RADIOLOGICA-DIAGNOSIS, 1973, 14 (03): : 353 - 367
  • [10] AN INVESTIGATION OF THE RADIATION-DOSE TO STAFF DURING CARDIAC RADIOLOGICAL STUDIES
    JEANS, SP
    FAULKNER, K
    LOVE, HG
    BARDSLEY, RA
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689): : 419 - 428