INTRINSIC SPATIAL-RESOLUTION LIMIT OF SCINTILLATION GAMMA-CAMERAS

被引:0
|
作者
PERKOV, AI
FEDOTOV, SN
机构
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Using the Monte Carlo method, we calculated the limit to the intrinsic spatial resolution of scintillation gamma-cameras, which is determined by gamma-quanta interacting with the scintillator. The calculations were for a scintillator in the shape of an infinitely large flat uniform layer of finite thickness, onto which an infinitely narrow beam of gamma-quanta is normally incident. The intrinsic spatial resolution was calculated for NaI(Tl), CsI(Tl), and Bi4Ge3O12 scintillators with thicknesses varying from (1/4) to 3 in. and for incident gamma-radiation energies ranging in between 0.5-5 MeV.
引用
收藏
页码:617 / 621
页数:5
相关论文
共 50 条
  • [41] DYNAMIC SPATIAL-RESOLUTION
    GODDARD, BA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (06): : 1144 - 1150
  • [42] SPATIAL-RESOLUTION OF THE GALAGO
    LANGSTON, A
    CASAGRANDE, VA
    FOX, R
    [J]. VISION RESEARCH, 1986, 26 (05) : 791 - 796
  • [43] A FIELD SURVEY OF GAMMA-CAMERAS IN FINLAND - A COMPREHENSIVE NATIONAL STUDY
    KARLSSON, HE
    POYHONEN, L
    SAUKKONEN, H
    VAURAMO, E
    VIRJO, A
    [J]. NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1982, 13 (05): : 228 - &
  • [44] Investigation of the Intrinsic Spatial Resolution of an Intensified EMCCD Scintillation Camera
    Meng, L. J.
    Fu, G.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2508 - 2517
  • [45] COMPUTER-ASSISTED QUALITY-CONTROL OF GAMMA-CAMERAS
    HUTTON, BF
    CORMACK, J
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1979, 9 (05): : 624 - 624
  • [46] A portable device for small animal SPECT imaging in clinical gamma-cameras
    Aguiar, P.
    Silva-Rodriguez, J.
    Gonzalez-Castano, D. M.
    Pino, F.
    Sanchez, M.
    Herranz, M.
    Iglesias, A.
    Lois, C.
    Ruibal, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [47] COLLISION CASCADE LIMIT TO SPATIAL-RESOLUTION IN FOCUSED ION-BEAM PROCESSES
    BETZ, G
    RUDENAUER, F
    [J]. APPLIED SURFACE SCIENCE, 1991, 51 (1-2) : 103 - 112
  • [48] ON THE SPATIAL-RESOLUTION OF CLINICAL THERMOMETERS
    GERIG, LH
    SZANTO, J
    RAAPHORST, GP
    [J]. MEDICAL PHYSICS, 1992, 19 (03) : 679 - 684
  • [49] SPATIAL-RESOLUTION IN DIGITAL MAMMOGRAPHY
    KARSSEMEIJER, N
    FRIELING, JTM
    HENDRIKS, JHCL
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (05) : 413 - 419
  • [50] THE LIMITS OF SPATIAL-RESOLUTION IN PIXE
    LEGGE, GJF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 22 (1-3): : 115 - 120