CONTINUOUS SPIROMETRY FOR DETECTION OF DOUBLE-LUMEN ENDOBRONCHIAL TUBE DISPLACEMENT

被引:43
|
作者
BARDOCZKY, GI
LEVARLET, M
ENGELMAN, E
DEFRANCQUEN, P
机构
[1] Department of Anaesthesiology and Thoracic Surgery, Erasme University Hospital, Free University of Brussels, 1070 Brussels
关键词
ANESTHETIC TECHNIQUES; FIBEROPTIC BRONCHOSCOPY; ONE-LUNG VENTILATION; INTUBATION ENDOBRONCHIAL; MONITORING SPIROMETRY;
D O I
10.1093/bja/70.5.499
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Flow-volume and pressure-volume loops were measured with continuous spirometry in 49 patients in whom the trachea was intubated ''blindly '' with a double-lumen endobronchial tube for thoracic surgery. Nineteen endobronchial tubes were malpositioned by fibreoptic bronchoscopic criteria; 63% of these were suspected because of the configuration of the spirometric loops. During positioning of the patient and during operation, 34.7% of the endobronchial tubes migrated from the initially correct or corrected position. The secondary displacements were identified by abnormal loop configurations and confirmed with fibreoptic bronchoscopy. Continuous spirometric monitoring is helpful in detecting endobronchial tube displacement during intubation and surgery.
引用
收藏
页码:499 / 502
页数:4
相关论文
共 50 条
  • [41] Independent lung ventilation using a double-lumen endobronchial tube by nasotracheal intubation
    K Yasumoto
    I Kagami
    [J]. Critical Care, 3 (Suppl 2):
  • [42] Postopertative sore throat and hoarseness in different textures of double-lumen endobronchial tube
    Hwang, Wonjung
    Jeon, Junpyo
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 : 33 - 33
  • [43] FAILURE OF DOUBLE-LUMEN ENDOBRONCHIAL TUBE PLACEMENT - CONGENITAL TRACHEAL STENOSIS IN AN ADULT
    SAITO, S
    DOHI, S
    TAJIMA, K
    [J]. ANESTHESIOLOGY, 1987, 66 (01) : 83 - 85
  • [44] Management of an unusual case of acute respiratory failure with a double-lumen endobronchial tube
    Venkatesan, K.
    Coleman, N. A.
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (11) : 2034 - 2035
  • [45] EVALUATION OF TRACHEAL TUBE EXCHANGERS (R) FOR REPLACEMENT OF DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    HANNALLAH, M
    [J]. ANESTHESIOLOGY, 1992, 77 (03) : 609 - 610
  • [46] A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic
    Heir, Jagtar Singh
    Guo, Shu-Lin
    Purugganan, Ronaldo
    Jackson, Tim A.
    Sekhon, Anupamjeet Kaur
    Mirza, Kazim
    Lasala, Javier
    Feng, Lei
    Cata, Juan P.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 267 - 274
  • [47] DOUBLE-LUMEN ENDOBRONCHIAL TUBES FOR PATIENTS WITH TRACHEOSTOMIES
    COE, VL
    BRODSKY, JB
    MARK, JBD
    [J]. ANESTHESIA AND ANALGESIA, 1984, 63 (09): : 882 - 882
  • [48] Audit of double-lumen endobronchial intubation - Reply
    Seymour, A
    Prasad, B
    McKenzie, R
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (06) : 861 - 861
  • [49] Use of the GlideScope® for double-lumen endobronchial intubation
    Bussieres, J. S.
    Somma, J.
    Rousseau, A.
    Harvey, L.
    [J]. ANAESTHESIA, 2014, 69 (02) : 181 - 182
  • [50] A CATHETER MOUNT FOR DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    WELSH, BE
    CONN, AW
    [J]. CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1970, 17 (02) : 183 - &