LIMITATIONS OF CLEARANCE DETERMINATION USING THE SINGLE SAMPLE DISTRIBUTION VOLUME METHOD - AN ERROR ANALYSIS ON THE BASIS OF COMPARTMENT MODELS

被引:0
|
作者
KOTZERKE, J
BURCHERT, W
WIESE, H
VONSMEKAL, U
HUNDESHAGEN, H
机构
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1992年 / 19卷 / 01期
关键词
KIDNEY FUNCTION; KIDNEY RADIONUCLIDE STUDIES; EFFECTIVE RENAL PLASMA FLOW (ERPF); TAUXES METHOD; ERROR CALCULATION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate the error possibly contained in the single sample distribution volume method for the determination of renal clearance, a mathematical model was applied to describe the effect of changes in distribution volume, clearance, intravascular space, intracompartmental exchange and the time point of blood sampling. The method was found to be valid only under well-defined circumstances (T(opt) = 45 +/- 5 min, Cl = 390 +/- 50 ml/min, V(d) = 16.7 +/- 41, alpha = 0.05. V1 ml/min, V1/V(d) = 0.5 +/- 0.05) as shown in sample calculations. Two-compartment model-based error calculations demonstrate that this technique implies at best an uncertainty of +/- 10% or more. Whilst it can be used preferably in healthy, normal-weight adults, it is not applicable, without error, under all other circumstances.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [31] Determination of halogens and sulfur in honey: a green analytical method using a single analysis
    Mesko, Marcia F.
    Balbinot, Fernanda P.
    Scaglioni, Priscila T.
    Nascimento, Mariele S.
    Picoloto, Rochele S.
    da Costa, Vanize C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (24) : 6475 - 6484
  • [32] Determination of halogens and sulfur in honey: a green analytical method using a single analysis
    Marcia F. Mesko
    Fernanda P. Balbinot
    Priscila T. Scaglioni
    Mariele S. Nascimento
    Rochele S. Picoloto
    Vanize C. da Costa
    Analytical and Bioanalytical Chemistry, 2020, 412 : 6475 - 6484
  • [33] A convenient method and numerical tables for sample size determination in longitudinal-experimental research using multilevel models
    Usami, Satoshi
    BEHAVIOR RESEARCH METHODS, 2014, 46 (04) : 1207 - 1219
  • [34] A convenient method and numerical tables for sample size determination in longitudinal-experimental research using multilevel models
    Satoshi Usami
    Behavior Research Methods, 2014, 46 : 1207 - 1219
  • [35] A SINGLE-SPECIMEN DETERMINATION OF JLC BY THE ULTRASONIC METHOD AND ANALYSIS OF ITS STATISTICAL DISTRIBUTION CHARACTERISTICS
    HIRANO, K
    KOBAYASHI, H
    NAKAZAWA, H
    JOURNAL OF TESTING AND EVALUATION, 1985, 13 (05) : 356 - 362
  • [36] ESTIMATION OF EXTRACELLULAR FLUID VOLUME FROM PLASMA-CLEARANCE ON TECHNETIUM-99M DTPA BY A SINGLE-INJECTION, 2-SAMPLE METHOD
    RUSSELL, CD
    BISCHOFF, PG
    ROWELL, KL
    LLOYD, LK
    DUBOVSKY, EV
    JOURNAL OF NUCLEAR MEDICINE, 1988, 29 (02) : 255 - 258
  • [37] Determination of particle shape distribution of clay using an automated AFM image analysis method
    Gelinas, Veronique
    Vidal, David
    POWDER TECHNOLOGY, 2010, 203 (02) : 254 - 264
  • [38] A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
    Ewa Zalewska
    Sanjeev D. Nandedkar
    Irena Hausmanowa-Petrusewicz
    Medical & Biological Engineering & Computing, 2012, 50 : 1309 - 1314
  • [39] A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis
    Zalewska, Ewa
    Nandedkar, Sanjeev D.
    Hausmanowa-Petrusewicz, Irena
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (12) : 1309 - 1314
  • [40] Sample size determination using type I error and power when conducting a Confirmatory Factor Analysis (CFA): a simulation study
    Anthoine, Emmanuelle
    Moret, Leila
    Sebille, Veronique
    Hardouin, Jean-Benoit
    QUALITY OF LIFE RESEARCH, 2013, 22