Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

被引:0
|
作者
Ataei, Abtin [1 ,2 ,3 ]
Nowrouzi, Ali [1 ,2 ]
Choi, Jun-Ki [3 ]
机构
[1] Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Tehran, Iran
[2] Islamic Azad Univ, Sci & Res Branch, Tehran, Iran
[3] Univ Dayton, Dept Mech & Aerosp Engn, Dayton, OH 45469 USA
关键词
indoor air quality; ventilation; contaminants; modeling; ASHRAE; 62;
D O I
10.12989/aer.2015.4.3.143
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide (CO2) and carbon monoxide (CO) were considered. CO and CO2 are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, CO2 is generated from occupants' respirations. To show how that approach works, a sample house with the area of 80 m(2) located in Tehran was considered as an illustrative case study. The results showed that CO2 concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the CO2 concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 50 条
  • [41] Investigation of indoor air quality at residential houses in Agra, India - a case study
    Lawrence, AJ
    Satsangi, GS
    Taneja, A
    [J]. AIR POLLUTION XI, 2003, 13 : 433 - 442
  • [42] Investigation of indoor air quality at residential homes in Hong Kong - case study
    Lee, SC
    Li, WM
    Ao, CH
    [J]. ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 225 - 237
  • [43] Ventilation and Indoor Air Quality in 40 Small and Medium Sized Commercial Buildings in California: Indoor Air Quality Methods and Findings
    Bennett, Deborah
    Apte, Michael
    Trout, Amber
    Powers, Michael
    Maddalena, Randy
    Russell, Marion
    [J]. EPIDEMIOLOGY, 2011, 22 (01) : S44 - S44
  • [44] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    [J]. ATMOSPHERE, 2022, 13 (10)
  • [46] Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States
    Xiong, Youyou
    Krogmann, Uta
    Mainelis, Gediminas
    Rodenburg, Lisa A.
    Andrews, Clinton J.
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2015, 50 (03): : 225 - 242
  • [47] Indoor and outdoor air quality investigation at six residential buildings in Hong Kong
    Lee, Shun-Cheng
    Chang, Maureen
    Chan, Ka-Yee
    [J]. Environment International, 1999, 25 (04): : 489 - 496
  • [48] NUMERICAL INVESTIGATIONS OF EFFECT OF INDOOR AIR QUALITY ON THERMAL COMFORT IN RESIDENTIAL BUILDINGS
    Krzaczek, M.
    Tejchman, J.
    [J]. ARCHIVES OF CIVIL ENGINEERING, 2014, 60 (01) : 91 - 121
  • [49] Ventilation and Air Heating of Residential Buildings.
    Bierling, H.-J.
    [J]. Eta. Elektrowarme im technischen Ausbau, 1985, 43 (01):
  • [50] Improving the Indoor Air Quality of Residential Buildings during Bushfire Smoke Events
    Rajagopalan, Priyadarsini
    Goodman, Nigel
    [J]. CLIMATE, 2021, 9 (02) : 1 - 14