Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

被引:0
|
作者
Ataei, Abtin [1 ,2 ,3 ]
Nowrouzi, Ali [1 ,2 ]
Choi, Jun-Ki [3 ]
机构
[1] Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Tehran, Iran
[2] Islamic Azad Univ, Sci & Res Branch, Tehran, Iran
[3] Univ Dayton, Dept Mech & Aerosp Engn, Dayton, OH 45469 USA
关键词
indoor air quality; ventilation; contaminants; modeling; ASHRAE; 62;
D O I
10.12989/aer.2015.4.3.143
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide (CO2) and carbon monoxide (CO) were considered. CO and CO2 are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, CO2 is generated from occupants' respirations. To show how that approach works, a sample house with the area of 80 m(2) located in Tehran was considered as an illustrative case study. The results showed that CO2 concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the CO2 concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 50 条
  • [1] The impact of design ventilation rates on the indoor air quality in residential buildings: An Italian case study
    Moschetti, Roberta
    Carlucci, Salvatore
    [J]. INDOOR AND BUILT ENVIRONMENT, 2017, 26 (10) : 1397 - 1419
  • [2] Indoor air quality for residential buildings
    Sherman, M
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 26 - 30
  • [3] Smart ventilation energy and indoor air quality performance in residential buildings: A review
    Guyot, Gaelle
    Sherman, Max H.
    Walker, Iain S.
    [J]. ENERGY AND BUILDINGS, 2018, 165 : 416 - 430
  • [4] IMPACT OF REDUCED INFILTRATION AND VENTILATION ON INDOOR AIR-QUALITY IN RESIDENTIAL BUILDINGS
    HOLLOWELL, CD
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 60 - 60
  • [5] A study on indoor air quality of urban residential buildings in China
    Yoshino, H
    Zhao, J
    Yoshino, Y
    Kumagai, K
    Ni, YY
    Li, ZH
    Liu, J
    Shigeno, T
    Miyasaka, H
    Yanagizawa, Y
    [J]. BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 208 - 215
  • [6] A study on indoor air quality of urban residential buildings in China
    Zhao, J
    Yoshino, H
    Yoshino, Y
    Kumagai, K
    Ni, Y
    Li, Z
    Liu, J
    Shigeno, T
    Miyasaka, H
    Yanagisawa, Y
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 543 - 547
  • [7] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    [J]. ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [8] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [9] Discussion on Ventilation Requirement for Meeting Indoor Air Quality
    Lin, Mengjie
    Liu, Qinqin
    Peng, Zimao
    [J]. ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2471 - 2474
  • [10] THERMAL IMPROVEMENT IN RESIDENTIAL BUILDINGS IN VIEW OF THE INDOOR AIR QUALITY - CASE STUDY FOR POLISH DWELLING
    Blaszczok, Monika
    Baranowski, Andrzej
    [J]. ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2018, 11 (03) : 121 - 130