Multidetector computed tomography evaluation of candidates for transcatheter aortic valve implantation

被引:3
|
作者
Guillen Subiran, M. E. [1 ]
Ros Mendoza, L. H. [1 ]
Angulo Hervias, E. [1 ]
Yaguee Romeo, D. [1 ]
Nunez Motilva, M. E. [1 ]
机构
[1] Hosp Univ Miguel Servet, Serv Radiodiagnost, Zaragoza, Spain
来源
RADIOLOGIA | 2018年 / 60卷 / 01期
关键词
Aortic valve stenosis; Transcatheter aortic valve replacement; Multidetector computed tomography;
D O I
10.1016/j.rx.2017.08.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In transcatheter aortic valve implantation (TAVI), a biologic valve mounted in a stent is implanted without removing the native valve. This procedure was first done in humans by Alain Cribier in 2002 and was included in clinical guidelines after the multicenter PARTNER (Placement of AoRtic TraNscathetER) randomized clinical trial, which showed that TAVI obtained better outcomes than conservative medical treatment and is an alternative to surgery in patients with high surgical risk. Candidates for TAVI must be assessed to determine whether the procedure is feasible, because TAVI is not ideal for all patients who are considered inoperable. Multidetector computed tomography plays an important role in the anatomic evaluation of candidates and in guiding the procedure in those who are finally selected. (c) 2017 SERAM. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:24 / 38
页数:15
相关论文
共 50 条
  • [21] Screening For Pulmonary Hypertension With Multidetector Computed Tomography Among Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
    O'Sullivan, Crochan J.
    Montalbetti, Matteo
    Zbinden, Rainer
    Kurz, David J.
    Bernheim, Alain M.
    Liew, Aaron
    Meyer, Matthias R.
    Tuller, David
    Eberli, Franz R.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
  • [22] Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): Imaging of the aortic root and iliac arteries
    Schoenhagen, Paul
    Kapadia, Samir R.
    Halliburton, Sandra S.
    Svensson, Lars G.
    Tuzcu, E. Murat
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (05) : 293 - 300
  • [23] COMPUTED TOMOGRAPHY PRIOR TO TRANSCATHETER AORTIC VALVE IMPLANTATION IN THE UNITED KINGDOM
    Harries, Iwan
    Weir-McCall, Jonathan R.
    Williams, Michelle C.
    Shambrook, James
    Roditi, Giles
    Bull, Russell
    Morgan-Hughes, Gareth J.
    Nicol, Edward D.
    Moss, Alastair J.
    HEART, 2020, 106 : A3 - A3
  • [24] Feasibility of transcatheter aortic valve implantation evaluated by multislice computed tomography
    Von Bodman, G.
    Kreidel, F.
    Rampp, T.
    Vicol, C.
    Schmoeckel, M.
    Reichart, B.
    Kilger, E.
    Zwissler, B.
    Block, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 750 - 750
  • [25] Diagnostic accuracy of computed tomography angiography for the exclusion of coronary artery disease in candidates for transcatheter aortic valve implantation
    Christopher Strong
    António Ferreira
    Rui Campante Teles
    Gustavo Mendes
    João Abecasis
    Gonçalo Cardoso
    Sara Guerreiro
    Pedro Freitas
    Ana Coutinho Santos
    Carla Saraiva
    João Brito
    Luís Raposo
    Pedro de Araújo Gonçalves
    Henrique Mesquita Gabriel
    Manuel de Sousa Almeida
    Miguel Mendes
    Scientific Reports, 9
  • [26] Diagnostic accuracy of computed tomography angiography for the exclusion of coronary artery disease in candidates for transcatheter aortic valve implantation
    Strong, Christopher
    Ferreira, Antonio
    Teles, Rui Campante
    Mendes, Gustavo
    Abecasis, Joao
    Cardoso, Goncalo
    Guerreiro, Sara
    Freitas, Pedro
    Santos, Ana Coutinho
    Saraiva, Carla
    Brito, Joao
    Raposo, Luis
    Goncalves, Pedro de Araujo
    Gabriel, Henrique Mesquita
    Almeida, Manuel de Sousa
    Mendes, Miguel
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [27] Thoracic Incidental Findings in Preoperative Computed Tomography Evaluation for Transcatheter Aortic Valve Implantation (TAVI)
    Hussien, Amira F.
    Jeudy, Jean
    Kligerman, Seth J.
    White, Charles S.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (03) : 183 - 188
  • [28] A novel contribution towards coherent and reproducible intravalvular measurement of the aortic annulus by multidetector computed tomography ahead of transcatheter aortic valve implantation
    Dennenthon, Julie
    Rioufol, Gilles
    Obadia, Jean-Francois
    Vergnat, Mathieu
    Green, Lisa
    Croisille, Pierre
    Boussel, Loic
    Peron, Julien
    Revel, Didier
    Finet, Gerard
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2015, 108 (05) : 281 - 292
  • [29] Three-Dimensional Transesophageal Echocardiography as an Alternative to Multidetector Computed Tomography in Aortic Annular Diameter Measurements for Transcatheter Aortic Valve Implantation
    Dima, Ciprian Nicusor
    Gaspar, Marian
    Mornos, Cristian
    Mornos, Aniko
    Deutsch, Petru
    Cioloca, Horia
    Cerbu, Simona
    Dinu, Mihai
    Hoinoiu, Bogdan
    Luca, Constantin Tudor
    Petrescu, Lucian
    BIOLOGY-BASEL, 2021, 10 (02): : 1 - 9
  • [30] Diagnostic accuracy of 64-slice multidetector computed tomography for the evaluation of coronary artery disease in patients selected for transcatheter aortic valve implantation
    Pontone, G.
    Andreini, D.
    Mushtaq, S.
    Bertella, E.
    Annoni, D. A.
    Muratori, M.
    Fusari, M.
    Ballerini, G.
    Bartorelli, A. L.
    Pepi, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A43 - A43