EXPERIMENTAL-ANALYSIS OF THE MULTI-BYPASS PRINCIPLE IN PULSE TUBE REFRIGERATORS

被引:18
|
作者
CAI, JH
WANG, JJ
ZHU, WX
ZHOU, Y
机构
[1] Cryogenic Laboratory, Academia Sinica, 2711 Beijing, PO Box
关键词
REFRIGERATION; MULTI-BYPASS METHOD; COAXIAL PULSE TUBE REFRIGERATOR;
D O I
10.1016/0011-2275(94)90155-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper describes the structural characteristics and the mechanical performance of a co-axial pulse tube refrigerator with a multi-bypass. Some experimental results and an experimental analysis of the multi-bypass method are also given. The minimum attainable temperature at the cold end of a co-axial pulse tube refrigerator with multi-bypass is 33 K at a vacuum of 1 x 10(-4) torr. This shows that the performance of a pulse lube refrigerator is comparable to that of a Stirling refrigerator. Moreover, pulse tube systems would probably be more extensively used than Stirling refrigerators because of their advantages in terms of structural simplicity and mechanical reliability.
引用
收藏
页码:713 / 715
页数:3
相关论文
共 50 条
  • [41] Experimental study of single linear compressor driving two pulse tube refrigerators with adjusting valves
    Chen, Xi
    Zeng, Yangping
    Jiang, Zhenhua
    Cao, Yonggang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 291 - 299
  • [42] THEORETICAL AND EXPERIMENTAL-ANALYSIS OF RIGHT VENTRICULAR BYPASS AND UNIVENTRICULAR CIRCULATORY SUPPORT
    KRESH, JY
    BROCKMAN, SK
    NOORDERGRAAF, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (02) : 121 - 127
  • [43] Analysis of DC gas flow in GM type double inlet pulse tube refrigerators
    Zhu, Shaowei
    Nogawa, Masafumi
    Inoue, Tatsuo
    CRYOGENICS, 2009, 49 (02) : 66 - 71
  • [44] Pressure gradients in oscillating flows in regenerators - Analysis and application to pulse-tube refrigerators
    Mayzus, P
    Fang, L
    Deng, X
    Bauwens, L
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 969 - 976
  • [45] NUMERICAL AND EXPERIMENTAL-ANALYSIS OF EDDY-CURRENT TESTING FOR A TUBE WITH CRACKS
    HASHIZUME, H
    YAMADA, Y
    MIYA, K
    TODA, S
    MORIMOTO, K
    ARAKI, Y
    SATAKE, K
    SHIMIZU, N
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (02) : 1469 - 1472
  • [46] Analysis of DC Control in Double-inlet GM type Pulse Tube Refrigerators for Detectors
    Due, B. Y.
    INFRARED TECHNOLOGY AND APPLICATIONS, AND ROBOT SENSING AND ADVANCED CONTROL, 2016, 10157
  • [47] Experimental analysis of free warm expander pulse tube
    Brito, MC
    Peskett, GD
    CRYOGENICS, 2001, 41 (10) : 757 - 762
  • [48] EXPERIMENTAL-ANALYSIS OF MULTI-ION IMPLANTED SILICON MOS DEVICE
    BALESTRA, C
    HUFF, HR
    HALVORSON, D
    CARTER, R
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (06) : C228 - C228
  • [49] Experimental study of staging method for two-stage pulse tube refrigerators for liquid 4He temperatures
    Univ of Giessen, Giessen, Germany
    Cryogenics, 12 (857-863):
  • [50] Experimental study of staging method for two-stage pulse tube refrigerators for liquid 4He temperatures
    Wang, C
    Thummes, G
    Heiden, C
    CRYOGENICS, 1997, 37 (12) : 857 - 863