IMPROVED LESION DETECTION IN SPECT USING MLEM RECONSTRUCTION

被引:12
|
作者
TOURASSI, GD [1 ]
FLOYD, CE [1 ]
MUNLEY, MT [1 ]
BOWSHER, JE [1 ]
COLEMAN, RE [1 ]
机构
[1] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27710
关键词
D O I
10.1109/23.289390
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Receiver Operating Characteristic (ROC) analysis was applied to determine if the Maximum Likelihood Expectation Maximization (MLEM) reconstruction algorithm improves lesion detectability in SPECT when compared with a Filtered Backprojection (FBP) algorithm. The performance of the reconstruction algorithms was evaluated based on cold lesion detection by human observers. Simulated SPECT projection data with added Poisson noise were reconstructed using the MLEM and the FBP algorithms. The parameters of the study, including lesion size and total counts, were chosen to maximize the statistical power of the test. Three hundred images were generated, and nine observers were employed for the study. The average ROC curves for both reconstruction methods were measured. Diagnostic performance was quantified using the area under the ROC curves. MLEM showed improved detectability for all the observers. Observer P-values were calculated, and Student's t-test was performed in order to verify the statistical significance of the observed improvement.
引用
收藏
页码:780 / 783
页数:4
相关论文
共 50 条
  • [41] MLEM image reconstruction algorithm based on physical constraints
    Zhang, Bin
    Wang, Ying
    Ai, Xian-Yun
    Wei, Xing
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 : 668 - 672
  • [42] Improved lesion detection from spatially adaptive, minimally complex, Pixons® reconstruction of planar scintigraphic images
    Wesolowski, CA
    Yahil, A
    Puetter, RC
    Babyn, PS
    Gilday, DL
    Khan, MZ
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (01) : 65 - 81
  • [43] Sequential Regularized MLEM Reconstruction Method for Incomplete Sinograms
    Tuna, Uygar
    Pepe, Antonietta
    Ruotsalainen, Ulla
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2553 - 2557
  • [44] Improved skin lesion edge detection method using Ant Colony Optimization
    Sengupta, Sudhriti
    Mittal, Neetu
    Modi, Megha
    SKIN RESEARCH AND TECHNOLOGY, 2019, 25 (06) : 846 - 856
  • [45] Improved breast lesion detection in mammogram images using a deep neural network
    Zhou, Wen
    Zhang, Xiaodong
    Ding, Jia
    Deng, Lingbo
    Cheng, Guanxun
    Wang, Xiaoying
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (04): : 588 - 595
  • [46] Lesion detection capability of posterior 180 degree SPECT compared to full 360 degree SPECT
    Khan, SH
    Holder, LE
    Kuhn, D
    Kelty, N
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 195P - 195P
  • [47] Anatomically guided reconstruction improves lesion quantitation and detectability in bone SPECT/CT
    Vuohijoki, Hanna E.
    Constable, Christopher J.
    Sohlberg, Antti O.
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (04) : 330 - 337
  • [48] Improved image reconstruction for dedicated cardiac SPECT with truncated projections
    Chan, Chung
    Dey, Joyoni
    Sinusas, Albert
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [49] Improved image reconstruction for dedicated cardiac SPECT with truncated projections
    Chan, C.
    Dey, J.
    Sinusas, A.
    Liu, C.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) : 666 - 666
  • [50] Parallelization of MLEM algorithm for PET reconstruction based on GPUs
    Vazquez, C.
    Rodriguez-Alvarez, M. J.
    Correcher, C.
    Gonzalez, A. J.
    Sanchez, F.
    Conde, P.
    Benlloch, J. M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,