Stator windings condition diagnosis of voltage inverter-fed induction motor in open and closed-loop control structures

被引:10
|
作者
Wolkiewicz, Marcin [1 ]
Tarchala, Grzegorz [1 ]
Kowalski, Czeslaw T. [1 ]
机构
[1] Wroclaw Univ Technol, Dept Elect Machines Drives & Measurements, Ul Smoluchowskiego19, PL-50370 Wroclaw, Poland
关键词
induction motor; shorted turns; scalar control; vector control DFOC;
D O I
10.1515/aee-2015-0007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with detection of the stator windings shorted turns in an induction motor drive working under open (scalar) and closed loop (Direct Field Oriented DFO) control structures. In order to detect the early stage of stator winding fault, the analysis of symmetrical and principal components of stator voltages and currents is used. Experimental results obtained from a specially prepared induction motor are presented.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [41] Common Mode Current Reduction in an Inverter-Fed Induction Motor Control System
    Yan, Wenguang
    PROCEEDINGS OF THE 48TH IEEE CONFERENCE ON DECISION AND CONTROL, 2009 HELD JOINTLY WITH THE 2009 28TH CHINESE CONTROL CONFERENCE (CDC/CCC 2009), 2009, : 7866 - 7871
  • [42] Stator Current Demodulation Using Hilbert Transform for Inverter-Fed Induction Motor at Low Load Conditions
    Khelfi, H.
    Hamdani, S.
    Nacereddine, K.
    Chibani, Y.
    PROCEEDINGS 2018 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2018, : 796 - 800
  • [43] Wavelet-based real-time stator fault detection of inverter-fed induction motor
    Akhil Vinayak, B.
    Anjali Anand, K.
    Jagadanand, G.
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (01) : 82 - 90
  • [44] Application of online voltage mismatch condition monitoring of induction motor stator windings in a mining environment
    Sottile, J
    Trutt, FC
    Kohler, JL
    2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1637 - 1644
  • [45] Speed Adaptive Voltage Closed-Loop Field-Weakening Control for Induction Motor Drives
    Wang, Bo
    Zhang, Jing
    Yu, Yong
    Zhang, Xu
    Xu, Dianguo
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 7078 - 7083
  • [46] Doubly Fed Induction Generator Open Stator Synchronized Control during Unbalanced Grid Voltage Condition
    Khan, Akrama
    Hu, Xiao Ming
    Khan, Mohamed Azeem
    Barendse, Paul
    ENERGIES, 2020, 13 (12)
  • [47] Fault diagnosis of voltage-fed inverter for induction motor drive
    Chrzan, PJ
    Szczesny, R
    ISIE'96 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 1996, : 1011 - 1016
  • [48] Stator winding turn-fault detection for closed-loop induction motor drives
    Tallam, RM
    Habetler, TG
    Harley, RG
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1553 - 1557
  • [49] Study and design on current control loop of vector control of PWM inverter-fed synchronous motor
    Zhang, Bo
    Li, Zhong
    Mao, Zongyuan
    Kongzhi Lilun Yu Yinyong/Control Theory and Applications, 1999, 16 (05): : 664 - 668
  • [50] Influence of Closed-Loop Control Operations on Detecting Induction Machine Stator Faults
    Meo, S.
    Ometto, A.
    Rotondale, N.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (03): : 4359 - 4365