Validation of the generalized model of two-phase thermosyphon loop based on experimental measurements of volumetric flow rate

被引:4
|
作者
Bielinski, Henryk [1 ]
机构
[1] Polish Acad Sci, Inst Fluid Flow Machinery, Fiszera 14, PL-80231 Gdansk, Poland
关键词
Thermosyphon loop; Two-phase flow; Minichannels;
D O I
10.1515/aoter-2016-0023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The current paper presents the experimental validation of the generalized model of the two-phase thermosyphon loop. The generalized model is based on mass, momentum, and energy balances in the evaporators, rising tube, condensers and the falling tube. The theoretical analysis and the experimental data have been obtained for a new designed variant. The variant refers to a thermosyphon loop with both minichannels and conventional tubes. The thermosyphon loop consists of an evaporator on the lower vertical section and a condenser on the upper vertical section. The one-dimensional homogeneous and separated two-phase flow models were used in calculations. The latest minichannel heat transfer correlations available in literature were applied. A numerical analysis of the volumetric flow rate in the steady-state has been done. The experiment was conducted on a specially designed test apparatus. Ultrapure water was used as a working fluid. The results show that the theoretical predictions are in good agreement with the measured volumetric flow rate at steady-state.
引用
收藏
页码:109 / 138
页数:30
相关论文
共 50 条
  • [31] Experimental study on closed-loop two-phase thermosyphon devices for cooling MCMs
    Na, MK
    Jeon, JS
    Kwak, HY
    Nam, SS
    HEAT TRANSFER ENGINEERING, 2001, 22 (02) : 29 - 39
  • [32] An experimental study of a two-phase closed loop thermosyphon with dual evaporator in parallel arrangement
    Chul Ju Kim
    Byoung Ok Yoo
    Yong Joo Park
    Journal of Mechanical Science and Technology, 2005, 19 : 189 - 198
  • [33] A Research of Closed Loop Two-Phase Thermosyphon Based on Lattice Boltzmann Method
    Zheng, Wen-Han
    Hong, Fang-Jun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (02): : 462 - 467
  • [34] EXPERIMENTAL STUDY OF THE HEAT TRANSFER CHARACTERISTICS OF A TWO-PHASE DOUBLE-LOOP THERMOSYPHON
    Chen, K. S.
    Tsai, S. T.
    Yu, W. T.
    EXPERIMENTAL HEAT TRANSFER, 1991, 4 (02) : 171 - 188
  • [35] Measurement of the performances of a transparent closed loop two-phase thermosyphon
    Agostini, B.
    Habert, M.
    ADVANCED COMPUTATIONAL METHODS AND EXPERIMENTS IN HEAT TRANSFER XI, 2010, 68 : 227 - 238
  • [36] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360
  • [37] HEAT TRANSFER PERFORMANCE OF A PULSATED TWO-PHASE LOOP THERMOSYPHON
    Ashraful, Islam Md.
    Ashiqur, Rahman Md.
    Mohammed, Alam
    IMECE 2008: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, VOL 10, PTS A-C, 2009, : 1411 - 1419
  • [38] Two-Phase Closed-Loop Thermosyphon for Electronic Cooling
    Chang, C. -C.
    Kuo, S. -C.
    Ke, M. -T.
    Chen, S. -L.
    EXPERIMENTAL HEAT TRANSFER, 2010, 23 (02) : 144 - 156
  • [39] Development of transient thermal-hydraulic analysis model for the two-phase loop thermosyphon
    Zhang, Wenwen
    Hao, Wentao
    Wu, Xubin
    APPLIED THERMAL ENGINEERING, 2024, 243
  • [40] Transient characteristics of a two-phase thermosyphon loop for multichip module
    Nam, SS
    Choi, SB
    Kim, JH
    Kwak, HY
    ETRI JOURNAL, 1998, 20 (03) : 284 - 300