PERCUTANEOUS BALLOON AORTIC VALVULOPLASTY - ACUTE AND 30-DAY FOLLOW-UP RESULTS IN 674 PATIENTS FROM THE NHLBI BALLOON VALVULOPLASTY REGISTRY

被引:0
|
作者
BASHORE, TM
BERMAN, AD
DAVIDSON, CJ
MICKEL, MC
KENNEDY, W
DAVIS, KB
机构
关键词
AORTIC STENOSIS; AORTIC VALVULOPLASTY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Percutaneous balloon aortic valvuloplasty has been used as a therapeutic option for relief of valvular stenosis. This study describes patients undergoing initial percutaneous aortic balloon valvuloplasty enrolled in the National Heart, Lung, and Blood Institute (NHLBI) Balloon Valvuloplasty Registry. Methods and Results. Extensive baseline procedural and postprocedural data were tabulated in 674 patients during a 24-month period. Functional status was captured using standard methods and an overall functional scoring system. Complications were defined and divided into procedural, acute (within 24 hours), in-hospital, and within 30 days of the procedure. The patient population was elderly and symptomatic, with 83% > 70 years of age. New York Heart Association functional class (FC) III or IV congestive heart failure (CHF) was present in 76%, syncope or presyncope was present in 34%, and Canadian Heart Association class III or IV angina was present in 23%. Using an overall functional scoring system (0-100), 54% exhibited scores < 50. Comorbid disease was common. Forty-five percent possessed at least one serious noncardiac disability as a reason for valvuloplasty. Eighty percent of those seen by a cardiothoracic surgeon were believed inappropriate for aortic valve replacement. Hemodynamically, the aortic valve area increased from 0.5 +/- 0.2 cm2 to 0.8 +/- 0.3 cm2 (p < 0.0001), accompanied by a fall in mean and peak aortic valve gradient from 55 +/- 21 and 65 +/- 28 mm Hg to 29 +/- 13 and 31 +/- 18 mm Hg, respectively (both p < 0.0001). Small but significant increases were observed in cardiac output, heart rate, and mean aortic pressure with minor declines in the pulmonary artery (PA) systolic and left ventricular (LV) end-diastolic pressure. One hundred sixty-seven (25%) experienced at least one significant complication within 24 hours, and 211 (31%) experienced a significant complication before discharge. Complications before hospital discharge included the need for transfusion (23%), vascular surgery (7%), cerebrovascular accident (3%), other systemic embolus (2%), myocardial infarction (2%), acute tubular necrosis (1%), or cardiac surgery (1%). Seventeen (3%) patients died during the procedure; 16 of those were due to cardiac causes. By hospital discharge, there was an additional 52 total deaths; 37 were due to cardiovascular causes. Between hospital discharge and 30 days, 23 additional deaths occurred; 18 were due to cardiac disease. At 30 days, therefore, there was a grand total of 92 (14%) deaths; 71 (11%) were due to cardiovascular-related causes. Univariate and logistic regression analysis of mortality revealed that death was most frequent in patients suffering multiorgan failure and poor LV systolic function. Thirty-day mortality was associated with a predefined high-risk subset of hypotension and NYHA class IV CHF (risk ratio, 4.4), blood urea nitrogen (BUN) > 30 mg/dl (risk ratio, 3.7), use of an antiarrhythmic (risk ratio, 2.9), and cardiac output < 3.0 l/min (risk ratio, 2.4). Of the survivors (86%) at 30 days, symptomatic improvement was generally present. Seventy-five percent experienced at least one functional class improvement in CHF, and 53% experienced at least a quartile improvement in overall functional status score. Conclusions. These data reveal that percutaneous aortic balloon valvuloplasty in an elderly and debilitated population can be done with low mortality but substantial morbidity. Mortality is greatest in patients with multiorgan failure resulting from poor cardiac output. In patients with reasonably preserved LV function who are otherwise inappropriate surgical candidates because of comorbid factors, survival and early improvement in symptomatic status are frequently observed after percutaneous aortic valvuloplasty.
引用
收藏
页码:2383 / 2397
页数:15
相关论文
共 50 条
  • [21] IMMEDIATE RESULTS AND LONG-TERM FOLLOW-UP AFTER REPEAT BALLOON AORTIC VALVULOPLASTY
    KUNTZ, RE
    TOSTESON, ANA
    MAITLAND, LA
    GORDON, P
    LEONARD, BM
    MCKAY, RG
    BERMAN, AD
    DIVER, DJ
    SAFIAN, RD
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (01): : 4 - 9
  • [22] Ten year follow-up of optimal candidates for percutaneous mitral balloon valvuloplasty
    LopezCuellar, JC
    Leon, MN
    Pathan, A
    Mahdi, NA
    Simosa, H
    McMellon, C
    Harrell, LC
    Palacios, IF
    CIRCULATION, 1997, 96 (08) : 2225 - 2225
  • [23] AORTIC ENDOCARDITIS AFTER PERCUTANEOUS BALLOON VALVULOPLASTY - THE ROLE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN EARLY DETECTION AND FOLLOW-UP
    CHIRILLO, F
    CAVARZERANI, A
    TOTIS, O
    BRUNI, A
    GIOMMI, L
    MARTON, F
    CUZZATO, V
    AMERICAN HEART JOURNAL, 1992, 124 (01) : 223 - 225
  • [24] FOLLOW-UP OF PATIENTS HAVING PERCUTANEOUS AORTIC VALVULOPLASTY (PAV)
    BLOCK, PC
    WALDMAN, H
    PALACIOS, IF
    CIRCULATION, 1987, 76 (04) : 496 - 496
  • [25] CLINICAL AND DOPPLER ECHOCARDIOGRAPHIC FOLLOW-UP AFTER PERCUTANEOUS BALLOON VALVULOPLASTY FOR AORTIC-VALVE STENOSIS
    GEIBEL, A
    KASPER, W
    REIFART, N
    FABER, T
    JUST, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (07): : 616 - 621
  • [26] Acute and long-term follow-up results of percutaneous mitral balloon valvuloplasty: a single-center study
    Korkmaz, Sule
    Demirkan, Burcu
    Guray, Yesim
    Yilmaz, Mehmet Birhan
    Aksu, Tolga
    Sasmaz, Hatice
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2011, 11 (06): : 515 - 520
  • [27] Long-Term Results of Congenital Aortic Stenosis Treatment in the Era of Percutaneous Balloon Valvuloplasty: Up to 33 Years Follow-Up
    Materna, Ondrej
    Tax, Petr
    Tomek, Viktor
    Koubsky, Karel
    Chaloupecky, Vaclav
    Janousek, Jan
    Reich, Oleg
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12):
  • [28] Evolution of percutaneous balloon aortic valvuloplasty in the treatment of patients with aortic stenosis
    Pendyala, L. K.
    Ben-dor, I.
    Waksman, R.
    MINERVA MEDICA, 2012, 103 (06) : 415 - 429
  • [29] ATRIAL SEPTAL-DEFECT AFTER PERCUTANEOUS MITRAL BALLOON VALVULOPLASTY - IMMEDIATE RESULTS AND FOLLOW-UP
    CASALE, P
    BLOCK, PC
    OSHEA, JP
    PALACIOS, IF
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (06) : 1300 - 1304
  • [30] Intermediate-term follow-up results of pulmonary balloon valvuloplasty in children
    Akçurin, G
    Kahramanyol, Ö
    Atakan, C
    TURKISH JOURNAL OF PEDIATRICS, 2000, 42 (02) : 126 - 131