SENSITIVE RAPID DETECTION OF MYOGLOBIN IN SERUM OF PATIENTS WITH MYOPATHY BY IMMUNOTURBIDIMETRIC ASSAY

被引:0
|
作者
LOVECE, S
KAGEN, LJ
机构
[1] HOSP SPECIAL SURG,DEPT LABS,535 E 70TH ST,NEW YORK,NY 10021
[2] HOSP SPECIAL SURG,DEPT MED,NEW YORK,NY 10021
关键词
MYOGLOBIN; MYOSITIS; MYOPATHY; POLYMOSITIS; DERMATOMYOSITIS; IMMUNOTURBIDIMETRY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To study immunoturbidimetry, a new technique for the quantitative determination of myoglobin in serum. Methods. Correlation with the standard technique of radioimmunoassay in sera of patients with and without myopathy. Results. Immunoturbidimetry was found to have a close correlation with the radioimmunoassay (RIA) method (r = 0.97, p = < 0.001), although it was slightly less sensitive. Compared to RIA, sensitivity was 87.8% and specificity, 98.6%. The turbidimetric method was performed considerably more rapidly than RIA. Using this method to assess patients with dermatomyositis and polymyositis, a close relationship to clinical findings was noted. However, of 64 samples with myoglobin level greater than 50 ng/ml, there were 3 instances (4.7%) where elevated myoglobin in the presence of normal CK suggested active disease, and there were 9 instances (14.1%) where myoglobin was normal in the presence of elevated CK. Seven of these cases were felt to reflect a lower sensitivity of the turbidimetric method. The other 2 are not explained. Serial measurements of serum myoglobin correlated well with clinical state in the course of 2 patients illustrated. Conclusions. Assay of serum myoglobin by immunoturbidimetry may provide a rapid and easily performed method without reliance on radiochemicals. It can be useful in clinical assessment of patients with myopathies, although sensitivity is not quite as high as that of RIA.
引用
收藏
页码:1331 / 1334
页数:4
相关论文
共 50 条
  • [41] EVALUATION OF A RAPID IMMUNOTURBIDIMETRIC ASSAY FOR OPSONIC FIBRONECTIN - SERIAL STUDIES IN INJURED PATIENTS AFTER CRYOPRECIPITATE INFUSION
    SABA, TM
    BLUMENSTOCK, FA
    CHO, E
    CIRCULATORY SHOCK, 1981, 8 (02) : 217 - 217
  • [42] A Sensitive Assay for Rapid Detection and Quantification of Aphanomyces euteiches in Soil
    Gangneux, Christophe
    Cannesan, Marc-Antoine
    Bressan, Melanie
    Castel, Lisa
    Moussart, Anne
    Vicre-Gibouin, Maite
    Driouich, Azeddine
    Trinsoutrot-Gattin, Isabelle
    Laval, Karine
    PHYTOPATHOLOGY, 2014, 104 (10) : 1138 - 1147
  • [43] Immunoturbidimetric assay for serum cystatin C using the Cobas Fara analyzer
    Garrido, MJ
    Hermida, J
    Tutor, JC
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (08) : 853 - 854
  • [44] Analytical evaluation of a new liquid immunoturbidimetric assay for the determination of ferritin in serum
    Molinario, Rossana
    Autilio, Chiara
    Pocino, Krizia
    Daloiso, Pio Dante
    Di Leva, Salvatore
    Zuppi, Cecilia
    Antenucci, Mirca
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (12) : E351 - E353
  • [45] BOVINE MYOGLOBIN - DETECTION OF MYOGLOBIN IN SERA AND URINE OF CALVES WITH NUTRITIONAL MYOPATHY BY IMMUNODIFFUSION METHOD
    OSAME, S
    ICHIJO, S
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1986, 48 (04): : 829 - 832
  • [46] DETECTION OF MYOGLOBIN IN SERUM AND URINE OF PATIENTS AFTER MYOCARDIAL-INFARCTION
    TAKAHASHI, R
    ARAI, S
    SAKAMOTO, M
    TAKISHIMA, T
    ITOH, M
    NUNOKAWA, T
    NUMAZAKI, Y
    ODASHIMA, H
    OGATA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1976, 40 (05): : 528 - 529
  • [47] IMMUNOTURBIDIMETRIC ASSAY FOR ESTIMATING FREE LIGHT-CHAINS OF IMMUNOGLOBULINS IN URINE AND SERUM
    TILLYER, CR
    IQBAL, J
    RAYMOND, J
    GORE, M
    MCILWAIN, TJ
    JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (06) : 466 - 471
  • [48] Development of a Rapid, Precise, and Sensitive Molecular Assay for ALK Fusion Detection
    Shang, Y.
    Jamba, M.
    Powell, M. J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2017, 19 (06): : 1051 - 1051
  • [49] Rapid urinary albumin measurement using sensitive immunoturbidimetric and ELISA methods.
    McCusker, MD
    Lamont, JV
    Fitzgerald, SP
    CLINICAL CHEMISTRY, 2000, 46 (06) : A181 - A181
  • [50] A sensitive one-pot ROA assay for rapid miRNA detection
    Hou, Zhihao
    Deng, Wenpeng
    Li, Alun
    Zhang, Ya
    Chang, Jianye
    Guan, Xinyue
    Chang, Yuxiao
    Wang, Kaile
    Wang, Xinjie
    Ruan, Jue
    ABIOTECH, 2024, 5 (03) : 298 - 308