BONE-MINERAL DENSITY IN HEALTHY NORMAL WOMEN AND REPRODUCIBILITY OF MEASUREMENTS IN SPINE AND HIP USING DUAL-ENERGY X-RAY ABSORPTIOMETRY

被引:58
|
作者
HADDAWAY, MJ [1 ]
DAVIE, MWJ [1 ]
MCCALL, IW [1 ]
机构
[1] ROBERT JONES & AGNES HUNT ORTHOPAED & DIST HOSP,DEPT DIAGNOST IMAGING,OSWESTRY SY10 7AG,SHROPS,ENGLAND
来源
BRITISH JOURNAL OF RADIOLOGY | 1992年 / 65卷 / 771期
关键词
BONE MINERAL DENSITY; REFERENCE VALUES; SPINE; HIP; DEXA;
D O I
10.1259/0007-1285-65-771-213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bone mineral density (BMD) using dual-energy X-ray absorptiometry (DEXA) has been measured in 394 healthy normal women. BMD is highest at the end of the 3rd decade and declines from 45 to 75 years by 0.0095 g/cm2/year in the lumbar spine and by 0.0052-0.0078 g/cm2/year in the upper femur depending on the site. BMD appears to increase in the 8th decade. Reproducibility (coefficient of variation (CV) of repeated measurements) was lowest in the lumbar spine (1.45%) and highest in Ward's triangle (4.29%). CV was not influenced by age at any site and by osteoporosis only in the femoral neck. BMD increased from L2 to L4 but the increase could not wholly be accounted for by the size of the vertebra, suggesting that the posterior elements were contributing to the observed increase of bone density.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 50 条
  • [1] BONE-MINERAL DENSITY IN HEALTHY DUTCH WOMEN - SPINE AND HIP MEASUREMENTS USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    ERDTSIECK, RJ
    POLS, HAP
    ALGRA, D
    KOOY, PPM
    BIRKENHAGER, JC
    NETHERLANDS JOURNAL OF MEDICINE, 1994, 45 (05): : 198 - 205
  • [2] BONE-MINERAL DENSITY MEASURED BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN HEALTHY FINNISH WOMEN
    LAITINEN, K
    VALIMAKI, M
    KETO, P
    CALCIFIED TISSUE INTERNATIONAL, 1991, 48 (04) : 224 - 231
  • [3] DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BONE-MINERAL DENSITY IN MYELOMA
    HOLMES, JA
    EVANS, WD
    COLES, RJ
    RAMSAHOYE, B
    WHITTAKER, JA
    EUROPEAN JOURNAL OF HAEMATOLOGY, 1994, 53 (05) : 309 - 311
  • [4] MEASUREMENT OF FOREARM BONE-MINERAL DENSITY IN NORMAL WOMEN BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    RYAN, PJ
    BLAKE, GM
    FOGELMAN, I
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (770): : 127 - 131
  • [5] BONE-MINERAL DENSITY MEASURED BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN NORMAL MEN
    KROGER, H
    LAITINEN, K
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1992, 22 (07) : 454 - 460
  • [6] Bone mineral density assessment -: Comparison of dual-energy X-ray absorptiometry measurements at the calcaneus, spine, and hip
    Sweeney, AT
    Malabanan, AO
    Blake, MA
    Weinberg, J
    Turner, A
    Ray, P
    Holick, ME
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (01) : 57 - 62
  • [7] COMPARISON OF DUAL-ENERGY X-RAY ABSORPTIOMETRY AND DUAL PHOTON-ABSORPTIOMETRY FOR BONE-MINERAL MEASUREMENTS OF THE LUMBAR SPINE
    WAHNER, HW
    DUNN, WL
    BROWN, ML
    RIGGS, BL
    MAYO CLINIC PROCEEDINGS, 1988, 63 (11) : 1075 - 1084
  • [8] DUAL-ENERGY X-RAY ABSORPTIOMETRY - A PRECISE METHOD OF MEASURING BONE-MINERAL DENSITY IN THE LUMBAR SPINE
    HANSEN, MA
    HASSAGER, C
    OVERGAARD, K
    MARSLEW, U
    RIIS, BJ
    CHRISTIANSEN, C
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (07) : 1156 - 1162
  • [9] Measurement of periprosthetic bone density in hip arthroplasty using dual-energy x-ray absorptiometry - Reproducibility of measurements
    Smart, RC
    Barbagallo, S
    Slater, GL
    Kuo, RS
    Butler, SP
    Drummond, RP
    Sekel, R
    JOURNAL OF ARTHROPLASTY, 1996, 11 (04): : 445 - 452
  • [10] Bone mineral density measurements in otosclerosis using dual-energy X-ray absorptiometry
    Tonuk, S. B.
    Koybasi, S.
    Bicer, Y. O.
    Alkan Temel, S.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) : 149 - 153