FACTOR-ANALYSIS FOR EXTRACTION OF BLOOD TIME-ACTIVITY CURVES IN DYNAMIC FDG-PET STUDIES

被引:0
|
作者
WU, HM [1 ]
HOH, CK [1 ]
CHOI, Y [1 ]
SCHELBERT, HR [1 ]
HAWKINS, RA [1 ]
PHELPS, ME [1 ]
HUANG, SC [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT MOLEC & MED PHARMACOL,DIV NUCL MED & BIOPHYS,LOS ANGELES,CA 90095
关键词
FACTOR ANALYSIS; BLOOD TIME-ACTIVITY CURVE EXTRACTION; POSITRON EMISSION TOMOGRAPHY; NITROGEN-13-AMMONIA; FLUORINE-18-FLUORODEOXYGLUCOSE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial sampling in dynamic PET studies can be eliminated by using left ventricular or aortic time-activity curves (TAC) obtained from user drawn regions of interest (ROIs) after appropriate spillover correction. In this study, we evaluated the feasibility of extracting the ''pure'' arterial TAC from dynamic PET images using factor analysis of dynamic structures (FADS). Methods: Computer simulations were used to study the performance of the FADS algorithm with positivity constraints. Ten canine N-13-ammonia and two human FDG-PET dynamic studies were used to extract the blood TACs from FADS. Plasma samples and compartmental model fittings were used to validate the accuracy of the FADS-generated blood factors. Results: We found that FADS with positivity constraints was sufficient to extract the blood factor from the composite dynamic images. The ''pure'' blood-pool TACs that matched well with the arterialized well counter measurements were generated from FADS in the canine and human studies. Conclusion: FADS has the potential to accurately extract ''pure'' blood TAC from dynamic PET images, allowing reliable quantitation of biological information from PET studies without blood sampling, ROI drawing or spillover correction.
引用
收藏
页码:1714 / 1722
页数:9
相关论文
共 50 条
  • [21] FACTOR-ANALYSIS OF DYNAMIC RADIONUCLIDE STUDIES
    SAMAL, M
    SUROVA, H
    BAKALA, J
    BARTAK, P
    STICH, V
    DIENSTBIER, Z
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1983, 14 (04): : 184 - &
  • [22] A METHOD FOR COMPUTING THE DERIVATIVE OF NOISY TIME-ACTIVITY CURVES AND ITS APPLICATION TO RADIOISOTOPE DYNAMIC ANALYSIS
    MURASE, K
    TANADA, S
    ISHINE, M
    MOGAMI, H
    HAMAMOTO, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (05): : 633 - 647
  • [23] Dynamic whole-body FDG-PET imaging for oncology studies
    Tamaki, Nagara
    Kotani, Tomoya
    Nishimura, Motoki
    Kaji, Tomohito
    CLINICAL AND TRANSLATIONAL IMAGING, 2022, 10 (03) : 249 - 258
  • [24] Dynamic whole-body FDG-PET imaging for oncology studies
    Nagara Tamaki
    Tomoya Kotani
    Motoki Nishimura
    Tomohito Kaji
    Clinical and Translational Imaging, 2022, 10 : 249 - 258
  • [25] Performance evaluation of principal component analysis in dynamic FDG-PET studies of recurrent colorectal cancer
    Thireou, T
    Strauss, LG
    Dimitrakopoulou-Strauss, A
    Kontaxakis, G
    Pavlopoulos, S
    Santos, A
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (01) : 43 - 51
  • [26] QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW USING DYNAMIC NITROGEN-13-AMMONIA PET STUDIES AND FACTOR-ANALYSIS OF DYNAMIC STRUCTURES
    WU, HM
    HOH, CK
    BUXTON, DB
    KUHLE, WG
    SCHELBERT, HR
    CHOI, Y
    HAWKINS, RA
    PHELPS, ME
    HUANG, SC
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) : 2087 - 2093
  • [28] Lifting wavelet transform for denoising PET time-activity curves: Effect on kinetic analyses
    Yaqub, Maqsood
    Boellaard, R.
    Lammertsma, A. A.
    NEUROIMAGE, 2006, 31 : T65 - T65
  • [29] Changes in FDG-PET Scan Activity in Sarcoidosis and Pulmonary Function Studies
    Hoo, G. W. Soo
    Chang, M. R.
    Sather, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [30] Performance evaluation of kinetic parameter estimation methods in dynamic FDG-PET studies
    Dai, Xiaoqian
    Chen, Zhe
    Tian, Jie
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (01) : 4 - 16