ACTIVATION TIME DETERMINATION BY HIGH-RESOLUTION UNIPOLAR AND BIPOLAR EXTRACELLULAR ELECTROGRAMS IN THE CANINE HEART

被引:64
|
作者
NDREPEPA, G
CAREF, EB
YIN, H
ELSHERIF, N
RESTIVO, M
机构
[1] VET ADM MED CTR,DIV CARDIOL 111A,BROOKLYN,NY 11209
[2] SUNY HLTH SCI CTR,DEPT MED,DIV CARDIOL,BROOKLYN,NY 11203
关键词
HEART CONDUCTION SYSTEM; ELECTRODE; ANISOTROPY; ELECTRICAL ACTIVATION; CARDIAC MAPPING;
D O I
10.1111/j.1540-8167.1995.tb00769.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To identify the optimal criteria for activation time (AT) determination of bipolar electrograms from normal hearts, a high-resolution cross electrode array comprising 128 unipolar electrodes of 500-mu m spacing was used to record extracellular potentials from the left ventricular epicardium of 12 dog hearts. Methods and Results: Recordings were made during broad wavefront propagation (B wave) and local elliptical wavefront propagation (E wave). Characteristics of 863 bipolar electrograms (1-mm spacing) were constructed from unipolar data standardized for differences in polarity, then classified morphologically. Features for bipolar AT determination were compared to the time of the negative peak of the first temporal derivative of a unipolar electrogram situated mid-way between the bipoles. During B wave, three distinct morphologies were observed: uniphasic (61%), biphasic (23%), and triphasic (16%). Peak voltage of uniphasic and triphasic signals was the best predictor of AT (error: 0.6 +/- 0.6 msec and 0.6 +/- 0.8 msec, respectively). During E wave, parallel orientation of the bipoles with respect to the direction of impulse propagation wavefront resulted in uniphasic signals (> 99%), while for perpendicular orientation of the bipoles, electrogram morphology was variable. For parallel orientation of the bipoles, peak negative voltage was the best predictor off AT for both longitudinal and transverse propagation, while for perpendicular bipole orientation, peak negative voltage was a less reliable predictor for propagation along both fiber axes. Increasing interpolar distance resulted in a degradation in AT accuracy for B wave (from 0.6 +/- 0.6 msec at 1 mm to 1.1 +/- 1.2 msec at 7 mm) and for E wave (from 0.4 +/- 0.3 msec at 1 mm to 3.1 +/- 2.9 msec at 7 mm). Conclusions: (1) The accuracy of bipoIar electrograms is sensitive to wavefront direction, bipole orientation, and interpolar distance; (2) peak negative voltage of uniphasic and triphasic signals is a reliable predictor of AT, but only for B wave; (3) a maximum interpolar distance of 2 mm and bipole orientation parallel to the direction of the impulse wavefront are minimally required for accurate determination of AT during impulse propagation initiated near the recording electrodes; and (4) for impulses initiated near the recording site in normal tissue, a biphasic or triphasic morphology almost certainly indicates that the bipolar electrode is oriented perpendicular to the wavefront direction, irrespective of fiber orientation.
引用
收藏
页码:174 / 188
页数:15
相关论文
共 50 条
  • [31] Automated Gastric Slow Wave Cycle Partitioning and Visualization for High-resolution Activation Time Maps
    Jonathan C. Erickson
    Greg O’Grady
    Peng Du
    John U. Egbuji
    Andrew J. Pullan
    Leo K. Cheng
    [J]. Annals of Biomedical Engineering, 2011, 39 : 469 - 483
  • [32] High-resolution estimation of the heart rate variability signal
    Harel, T.
    Gath, I.
    Ben-Haim, S.
    [J]. Medical and Biological Engineering and Computing, 1997, 35 (01): : 61 - 65
  • [33] Automated Gastric Slow Wave Cycle Partitioning and Visualization for High-resolution Activation Time Maps
    Erickson, Jonathan C.
    O'Grady, Greg
    Du, Peng
    Egbuji, John U.
    Pullan, Andrew J.
    Cheng, Leo K.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) : 469 - 483
  • [34] High-resolution coronary collateral distribution in the human heart
    Van Lier, M. G. J. T. B.
    Van Horssen, P.
    Schwarz, J. C. V.
    Van der Wal, A. C.
    Spaan, J. A. E.
    Siebes, M.
    Van den Wijngaard, J. P. H. M.
    [J]. CARDIOVASCULAR RESEARCH, 2014, 103
  • [35] A high-resolution computational model of the deforming human heart
    Viatcheslav Gurev
    Pras Pathmanathan
    Jean-Luc Fattebert
    Hui-Fang Wen
    John Magerlein
    Richard A. Gray
    David F. Richards
    J. Jeremy Rice
    [J]. Biomechanics and Modeling in Mechanobiology, 2015, 14 : 829 - 849
  • [36] High-resolution longitudinal MRI of the transition to heart failure
    Costandi, Peter N.
    McCulloch, Andrew D.
    Omens, Jeffrey H.
    Frank, Lawrence R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 714 - 720
  • [37] High-resolution estimation of the heart rate variability signal
    T. Harel
    I. Gath
    S. Ben-Haim
    [J]. Medical and Biological Engineering and Computing, 1997, 35 : 61 - 65
  • [38] High-resolution estimation of the heart rate variability signal
    Harel, T
    Gath, I
    BenHaim, S
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) : 61 - 65
  • [39] A high-resolution computational model of the deforming human heart
    Gurev, Viatcheslav
    Pathmanathan, Pras
    Fattebert, Jean-Luc
    Wen, Hui-Fang
    Magerlein, John
    Gray, Richard A.
    Richards, David F.
    Rice, J. Jeremy
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2015, 14 (04) : 829 - 849
  • [40] ANATOMY OF THE CANINE BRAIN USING HIGH-RESOLUTION COMPUTED-TOMOGRAPHY
    FIKE, JR
    LECOUTEUR, RA
    CANN, CE
    [J]. VETERINARY RADIOLOGY, 1981, 22 (06): : 236 - 243