Viscodilation of Schlemm's canal for the reduction of IOP via an ab-interno approach

被引:44
|
作者
Gallardo, Mark J. [1 ,2 ]
Supnet, Richard A. [1 ]
Ahmed, Iqbal Ike K. [3 ]
机构
[1] El Paso Eye Surg, 1201 N Mesa St,Ste G, El Paso, TX 79902 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[3] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
来源
CLINICAL OPHTHALMOLOGY | 2018年 / 12卷
关键词
IOP; primary open-angle glaucoma; ab-interno canaloplasty; glaucoma medication;
D O I
10.2147/OPTH.S177597
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare the 1-year efficacy and safety profile of ab-interno canaloplasty (ABiC) when performed as a stand-alone procedure or as an adjunct to cataract extraction in reducing IOP and glaucoma medication dependence. Patients and methods: This retrospective, comparative, consecutive case series included patients with uncontrolled primary open-angle glaucoma (POAG) who underwent ABiC as a stand-alone procedure or in conjunction with cataract extraction. Data were collected over a 12-month period. Primary outcome measures were mean lower IOP and mean number of glaucoma medications. Secondary endpoints included surgical and postsurgical complications and secondary interventions. Results: The study included 75 eyes of 68 patients (mean age: 73.7 +/- 9.9 years) with a mean baseline IOP of 20.4 +/- 4.7 mmHg on 2.8 +/- 0.9 medications, which reduced to 13.3 +/- 1.9 mmHg (n=73) on 1.1 +/- 1.1 medications at 12 months postoperative (both P<0.0001). At 12 months, 40% of eyes were medication free. In the ABiC/phacoemulsification subgroup (n=34 eyes), the mean IOP and medication use decreased from 19.4 +/- 3.7 mmHg on 2.6 +/- 1.0 medications preoperatively to 13.0 +/- 1.8 mmHg on 0.8 +/- 0.2 medications at 12 months (both P<0.001). In the stand-alone ABiC subgroup (n=41), the mean IOP and medication use decreased from 21.2 +/- 5.3 mmHg on 3.0 +/- 0.7 medications preoperatively to 13.7 +/- 1.9 mmHg on 1.3 +/- 1.1 medications at 12 months (P=0.001 and <0.001, respectively). No serious adverse events were recorded. Conclusion: These data demonstrate that ABiC was effective at reducing IOP and medication use in eyes with uncontrolled POAG with or without cataract surgery.
引用
收藏
页码:2149 / 2155
页数:7
相关论文
共 50 条
  • [21] Combining ab-interno canaloplasty and trabecular bypass stenting lowers IOP more than bypass stenting alone during phacoemulsification
    Heersink, Marius
    Heersink, Mila
    Dovich, Jesse
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [22] The implications of an ab interno vs. ab externo surgical approach on intraocular pressure (IOP) control
    Lee, Richard M. H.
    Bouremel, Yann
    Eames, Ian
    Brocchini, Steve
    Khaw, Peng Tee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [23] Positive correlation of blood reflux in Schlemm's canal and reduction of intraocular pressure after ab interno 360-degree viscocanalostomy in primary open-angle glaucoma
    Grieshaber, Matthias
    Pienaar, Ane
    Stegmann, Robert
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [24] Schlemm's canal cells and trabecular meshwork cells as potential targets in IOP modulation
    Karl, MO
    Fleischhauer, JC
    Stamer, WD
    Peterson-Yantorno, K
    Mitchell, CH
    Stone, RA
    Civan, MM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U184 - U184
  • [25] IOP-induced Changes in Schlemm's Canal Dimensions and the Relation to Shear Stress
    Ashpole, Nicole E.
    Mukherjee, Dibyendu
    Li, Guorong
    Maccarini, Paolo
    Sherwood, Joseph M.
    Ethier, C. Ross
    Overby, Darryl R.
    Farsiu, Sina
    Stamer, W. Daniel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [26] Clinical outcomes of canaloplasty via an ab-interno surgical technique using the iTrack device: a narrative review
    Norbert Koerber
    Simon Ondrejka
    International Ophthalmology, 2023, 43 : 2017 - 2027
  • [27] Combined ab-interno trabeculectomy and cataract surgery induces comparable intraocular pressure reduction in supine and sitting positions
    Caroline Gietzelt
    David Kiessling
    Randolf A.Widder
    Ludwig M.Heindl
    Claus Cursiefen
    Thomas S.Dietlein
    Philip Enders
    International Journal of Ophthalmology, 2021, 14 (08) : 1192 - 1198
  • [28] RESULTS FROM THE HORIZON TRIAL: A RANDOMIZED STUDY OF A SCHLEMM'S CANAL MICROSTENT FOR REDUCTION OF IOP IN PRIMARY OPEN ANGLE GLAUCOMA
    Harasymowycz, Paul
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 66 - 66
  • [29] Clinical outcomes of canaloplasty via an ab-interno surgical technique using the iTrack device: a narrative review
    Koerber, Norbert
    Ondrejka, Simon
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (06) : 2017 - 2027
  • [30] Ab externo Schlemm's canal surgery: Efficacy and safety outcomes
    Batailde, Gael
    Ginderachter, Alicia V.
    Eijgen, Jan V.
    Sunaric-Megevand, Gordana
    Stalmans, Ingeborg
    Lemmens, Sophie
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2024, 38 (04) : 322 - 331