A METHOD FOR REAL-TIME IN-VITRO OBSERVATION OF CAVITATION ON PROSTHETIC HEART-VALVES

被引:30
|
作者
ZAPANTA, CM [1 ]
LISZKA, EG [1 ]
LAMSON, TC [1 ]
STINEBRING, DR [1 ]
DEUTSCH, S [1 ]
GESELOWITZ, DB [1 ]
TARBELL, JM [1 ]
机构
[1] PENN STATE UNIV, APPL RES LAB, UNIVERSITY PK, PA 16802 USA
关键词
D O I
10.1115/1.2895797
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method for real-time in vitro observation of cavitation on a prosthetic heart valve has been developed. Cavitation of four blood analog fluids (distilled water, aqueous glycerin, aqueous polyacrylamide, and aqueous xanthan gum) has been documented for a Medtronic/Hall(TM) prosthetic heart valve. This method employed a Penn State Electrical Ventricular Assist Device in a mock circulatory loop that was operated in a partial filling mode associated with reduced atrial filling pressure. The observations were made on a valve that was located in the mitral position, with the cavitation occurring on the inlet side after valve closure on every cycle. Stroboscopic videography,was used to document the cavity life cycle. Bubble cavitation was observed on the valve occluder face. Vortex cavitation was observed at two locations in the vicinity of the valve occluder and housing. For each fluid, cavity growth and collapse occurred in less than one millisecond, which provides strong evidence that the cavitation is vaporous rather than gaseous. The cavity duration time was found to decrease with increasing atrial pressure at constant aortic pressure and beat rate. The area of cavitation was found to decrease with increasing delay time at a constant aortic pressure, atrial pressure, and bear rate. Cavitation was found to occur in each of the fluids, with the most cavitation seen in the Newtonian fluids (distilled water and aqueous glycerin).
引用
收藏
页码:460 / 468
页数:9
相关论文
共 50 条
  • [31] PROSTHETIC HEART-VALVES, ANTICOAGULANTS AND PREGNANCY
    IBARRAPEREZ, C
    NIZRAMOS, J
    GARCIAALONSO, A
    ECHAVARRIALUNA, J
    CHEST, 1985, 88 : S11 - S11
  • [32] PREGNANCY IN PATIENTS WITH PROSTHETIC HEART-VALVES
    ROBBINS, G
    KERNOFF, PBA
    BRITISH MEDICAL JOURNAL, 1983, 287 (6385): : 134 - 134
  • [33] BACTEREMIA IN PATIENTS WITH PROSTHETIC HEART-VALVES
    TORSETH, J
    ASHIKAGA, T
    BEATY, HN
    CLINICAL RESEARCH, 1989, 37 (04): : A911 - A911
  • [34] DYNAMIC CHARACTERISTICS OF PROSTHETIC HEART-VALVES
    SHE, JW
    LI, MY
    HUAN, LJ
    YU, YZ
    MEDICAL ENGINEERING & PHYSICS, 1995, 17 (04) : 273 - 281
  • [35] SIMPLE METHOD FOR ESTIMATING STRESSES IN NATURAL AND PROSTHETIC HEART-VALVES
    ROSSOW, MP
    GOULD, PL
    CLARK, RE
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1978, 6 (04): : 277 - 290
  • [36] VALVULAR HEART-DISEASE, INFECTED VALVES AND PROSTHETIC HEART-VALVES
    DALEN, JE
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (06): : C29 - C31
  • [37] FIBRINOLYTIC TREATMENT OF THROMBUS ON PROSTHETIC HEART-VALVES
    WITCHITZ, S
    VEYRAT, C
    MOISSON, P
    SCHEINMAN, N
    ROZENSTAJN, L
    BRITISH HEART JOURNAL, 1980, 44 (05): : 545 - 554
  • [38] PREGNANT-WOMEN WITH PROSTHETIC HEART-VALVES
    MCCOLGIN, SW
    MARTIN, JN
    MORRISON, JC
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1989, 32 (01): : 76 - 88
  • [39] PREVENTION OF THROMBOEMBOLISM INDUCED BY PROSTHETIC HEART-VALVES
    FUSTER, V
    BADIMON, L
    BADIMON, JJ
    CHESEBRO, J
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1988, 14 (01): : 50 - 58
  • [40] THE DOG AS A MODEL FOR EVALUATING PROSTHETIC HEART-VALVES
    JONES, RD
    DREHER, DM
    CROSS, FS
    ANNALS OF THORACIC SURGERY, 1989, 48 (03): : S4 - S5