Background and Purpose High-intensity transient signals detected by transcranial Doppler sonography have been associated with particulate cerebral emboli. Their clinical correlates are poorly understood. This study was undertaken to assess their relation to cerebral ischemia and to determine whether the severity of cerebral arterial stenosis has an impact on their occurrence. Methods We studied 96 arteries in 75 consecutive patients with extracranial or intracranial arterial lesions or potential cardiac sources of cerebral embolism. Sixty patients had histories of cerebral or retinal transient ischemic attacks or infarcts, and 15 were asymptomatic. The diagnosis of ischemia was based on the clinical presentation and was supported by extensive laboratory testing. A transcranial Doppler sonography unit equipped with special software for emboli detection was used. Signals were selected based on criteria established a priori. Results Signals were detected in the territories of 28.3% of symptomatic and 11.6% of asymptomatic arteries. The difference was significant (P=.045). When patients with suspected cardiac embolic sources were excluded, the difference between symptomatic (27.9%) and asymptomatic (2.9%) arteries remained significant (P=.003), and signals were more frequent distal to arteries with more than 50% area stenosis (23.5%) than arteries with stenoses equal to or less than 50% (3.7%) (P=.028). In patients with only extracranial internal carotid artery stenoses, the difference between these degrees of stenosis remained significant (P=.043). Conclusions We conclude that high-intensity transient signals are significantly more common in the territories of symptomatic arteries and distal to lesions causing more than 50% stenosis. These findings may have diagnostic and therapeutic applications.
引用
收藏
页码:1570 / 1573
页数:4
相关论文
共 50 条
  • [21] Transcranial high-intensity Doppler signals in patients with mechanical heart valve prostheses: Their relationship with abnormal intracavitary echoes
    Deklunder, G
    Lecroart, JL
    Savoye, C
    Coquet, B
    Houdas, Y
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (06): : 662 - 667
  • [22] PROSPECTIVE-STUDY TO COMPARE MR-ANGIOGRAPHY, TRANSCRANIAL DOPPLER, AND ANGIOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE
    ELSADEN, SM
    GRANT, EG
    SINGH, R
    COHEN, SN
    RADIOLOGY, 1995, 197 : 236 - 236
  • [23] PROSPECTIVE-STUDY TO COMPARE MR-ANGIOGRAPHY, TRANSCRANIAL DOPPLER, AND ANGIOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE
    ELSADEN, SM
    GRANT, EG
    SINGH, R
    COHEN, SN
    RADIOLOGY, 1995, 197 : 236 - 236
  • [24] Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients
    Milano, A
    D'Alfonso, A
    Codecasa, R
    De Carlo, M
    Nardi, C
    Orlandi, G
    Landucci, L
    Bortolotti, U
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 488 - 494
  • [25] Detection of high-intensity transient signals by Doppler ultrasound during percutaneous coronary interventions
    Bahrmann, P
    Werner, GS
    Wagner, M
    Ferrari, M
    Hopfe, J
    Voss, A
    Figulla, HR
    EUROPEAN HEART JOURNAL, 2004, 25 : 98 - 98
  • [26] HIGH-INTENSITY TRANSCRANIAL DOPPLER SIGNALS IN PATIENTS WITH POTENTIAL CARDIAC SOURCES OF EMBOLISM (EMB) AND IN NORMAL CONTROLS - A PROSPECTIVE-STUDY
    JOB, FP
    SLIWKA, U
    KOLOUCH, J
    WISSUWA, D
    MEYER, B
    NOTH, J
    FLACHSKAMPF, FA
    CIRCULATION, 1994, 90 (04) : 225 - 225
  • [27] High intensity transient signals measured by transcranial Doppler during transcatheter closure of atrial septal defect
    Suda, K.
    Kudo, Y.
    Tananari, Y.
    Itoh, S.
    Ishii, H.
    Nishino, H.
    Iemura, M.
    Maeno, Y.
    Yasunaga, H.
    Matsuishi, T.
    EUROPEAN HEART JOURNAL, 2009, 30 : 394 - 394
  • [28] Prospective evaluation of frequency and nature of transcranial high-intensity Doppler signals in prosthetic valve recipients - Meeting discussion
    Shah, P
    Milano, A
    Kleine, P
    Hwang, N
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (05): : 494 - 494
  • [29] Detection of cerebrovascular disease in patients with sickle cell disease using transcranial Doppler sonography: Correlation with MRI, MRA and conventional angiography
    Verlhac, S
    Bernaudin, F
    Tortrat, D
    Brugieres, P
    Mage, K
    Gaston, A
    Reinert, P
    PEDIATRIC RADIOLOGY, 1995, 25 : S14 - S19
  • [30] Impact of Transcatheter Aortic Valve Implantation on Microemboli 24 to 48 h After Valve Implantation Observed as High-Intensity Transient Signals on Transcranial Doppler: Prevalence and Implications
    Sharma, Navneet
    Heslin, Ryan
    Avvento, Peter
    Medamana, John
    Burdowski, Joseph
    Aleem, Saadat
    Manjur, Jahan
    Gasimli-Gamache, Leyla
    Yoo, Jeanwoo
    Bilfinger, Thomas
    Tannous, Henry
    Kort, Smadar
    Wiley, Jose
    Parikh, Puja
    Labropoulos, Nicos
    Pyo, Robert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B22 - B22