BASE-ISOLATED BUILDING CONNECTED TO ADJACENT BUILDING USING VISCOUS DAMPERS

被引:0
|
作者
Matsagar, Vasant A. [1 ]
Jangid, R. S. [2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, Maharashtra, India
[2] Indian Inst Technol, Dept Civil Engn, Mumbai, Maharashtra, India
关键词
adjacent building; base isolation; bearing displacement; earthquake; elastomeric bearing; pounding; sliding system; superstructure acceleration; viscous damper;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Seismic response of multi-storied base-isolated building on various isolation systems connected using viscous dampers to an adjacent dissimilar base-isolated or fixed-base building is investigated. The multi-storied buildings are modeled as a shear type structures with lateral degree-of-freedom at each floor, which are connected at different floor levels by the viscous dampers. Performance of this novel combination is studied by deriving the governing equations of motion and solving it in the incremental form using Newmark's step-by-step method of integration. The variation of top floor absolute acceleration and bearing displacement under different real earthquake ground motions is computed to study the behavior and effectiveness of the connected systems. It is concluded that connecting the two adjacent base-isolated buildings with the viscous dampers is helpful in controlling large bearing displacement in the base-isolated structures; thereby, eliminating isolator damages arising due to instability at large displacement or pounding with adjacent structures during the earthquakes. Parametric studies are also performed to identify optimal parameters such as damper damping and distribution pattern of viscous dampers to achieve the maximum response reduction in the damper-linked adjacent buildings. The connection of viscous dampers to adjacent structures are found to be most effective when: (i) the adjacent base-isolated and fixed-base buildings are connected, (ii) dissimilar isolation systems are used for the two adjacent buildings, (iii) the time periods of adjacent structures are well separated, and (iv) the superstructure flexibility is higher.
引用
收藏
页码:59 / 80
页数:22
相关论文
共 50 条
  • [31] Response of base-isolated USC hospital building in Northridge earthquake
    Nagarajaiah, Satish
    Xiaohong, Sun
    Journal of Structural Engineering, 2000, 126 (10) : 1177 - 1186
  • [32] Analysis, Design, and Construction of a Base-Isolated Multiple Building Structure
    Sorace, Stefano
    Terenzi, Gloria
    ADVANCES IN CIVIL ENGINEERING, 2014, 2014
  • [33] Experimental seismic performance of a base-isolated building with displacement limiters
    Du, Hongkai
    Wang, Yuandong
    Han, Miao
    Ibarra, Luis F.
    ENGINEERING STRUCTURES, 2021, 244
  • [34] NONLINEAR DYNAMIC ANALYSIS OF MULTIPLE BUILDING BASE-ISOLATED STRUCTURES
    TSOPELAS, PC
    NAGARAJAIAH, S
    CONSTANTINOU, MC
    REINHORN, AM
    COMPUTERS & STRUCTURES, 1994, 50 (01) : 47 - 57
  • [35] Response of base-isolated USC hospital building in Northridge earthquake
    Nagarajaiah, S
    Sun, XH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (10): : 1177 - 1186
  • [36] Base-isolated FCC building: Impact response in Northridge earthquake
    Nagarajaiah, S
    Sun, XH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (09): : 1063 - 1075
  • [37] Footfall Induced Vibration Response of a Base-Isolated Steel Building
    Malhotra R.
    Ndarowa C.
    Macrae G.A.
    Palermo A.
    Broglio S.
    Malhotra, Raunaq (rma184@uclive.ac.nz), 2018, Trans Tech Publications Ltd (763 KEM) : 992 - 1001
  • [38] SEISMIC RESPONSE OF THE SUPERSTRUCTURE AND ATTACHED EQUIPMENT IN A BASE-ISOLATED BUILDING
    TSAI, HC
    KELLY, JM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1989, 18 (04): : 551 - 564
  • [39] Feedback Vibration Control of a Base-Isolated Building with Delayed Measurements Using H∞ Techniques
    Karimi, H. R.
    Zapateiro, M.
    Luo, N.
    Rossell, J. M.
    2010 AMERICAN CONTROL CONFERENCE, 2010, : 750 - 755
  • [40] Performance of RC Frame Base-Isolated Building with Geotextile as Isolator Using UPBD Method
    Chaudhary A.K.
    Choudhury S.
    Journal of The Institution of Engineers (India): Series A, 2020, 101 (01) : 117 - 126