BASE-ISOLATED BUILDING CONNECTED TO ADJACENT BUILDING USING VISCOUS DAMPERS

被引:0
|
作者
Matsagar, Vasant A. [1 ]
Jangid, R. S. [2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, Maharashtra, India
[2] Indian Inst Technol, Dept Civil Engn, Mumbai, Maharashtra, India
关键词
adjacent building; base isolation; bearing displacement; earthquake; elastomeric bearing; pounding; sliding system; superstructure acceleration; viscous damper;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Seismic response of multi-storied base-isolated building on various isolation systems connected using viscous dampers to an adjacent dissimilar base-isolated or fixed-base building is investigated. The multi-storied buildings are modeled as a shear type structures with lateral degree-of-freedom at each floor, which are connected at different floor levels by the viscous dampers. Performance of this novel combination is studied by deriving the governing equations of motion and solving it in the incremental form using Newmark's step-by-step method of integration. The variation of top floor absolute acceleration and bearing displacement under different real earthquake ground motions is computed to study the behavior and effectiveness of the connected systems. It is concluded that connecting the two adjacent base-isolated buildings with the viscous dampers is helpful in controlling large bearing displacement in the base-isolated structures; thereby, eliminating isolator damages arising due to instability at large displacement or pounding with adjacent structures during the earthquakes. Parametric studies are also performed to identify optimal parameters such as damper damping and distribution pattern of viscous dampers to achieve the maximum response reduction in the damper-linked adjacent buildings. The connection of viscous dampers to adjacent structures are found to be most effective when: (i) the adjacent base-isolated and fixed-base buildings are connected, (ii) dissimilar isolation systems are used for the two adjacent buildings, (iii) the time periods of adjacent structures are well separated, and (iv) the superstructure flexibility is higher.
引用
收藏
页码:59 / 80
页数:22
相关论文
共 50 条
  • [1] Seismic rehabilitation of a base-isolated building using viscous dampers
    Hart, GC
    Brandow, G
    Johnston, R
    STRUCTURAL DESIGN OF TALL BUILDINGS, 2001, 10 (05): : 335 - 338
  • [2] Application of angular-mass dampers to base-isolated benchmark building
    Pradono, Mulyo Harris
    Iemura, Hirokazu
    Igarashi, Akira
    Kalantari, Afshin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 737 - 745
  • [3] Seismic mitigation of an existing building by connecting to a base-isolated building with visco-elastic dampers
    Yang, Zhidong
    Lam, Eddie S. S.
    STRUCTURAL ENGINEERING AND MECHANICS, 2015, 53 (01) : 57 - 71
  • [4] Optimization research for base-isolated structures with fluid viscous dampers
    Chen R.
    Wu J.
    Liu Y.
    Donà M.
    Jin J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (11): : 93 - 100
  • [5] Optimal Control of Accelerations in a Base-Isolated Building using Magneto-Rheological Dampers and Genetic Algorithms
    Lafontaine, Mario
    Moroni, Ofelia
    Sarrazin, Mauricio
    Roschke, Paul
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (08) : 1153 - 1171
  • [6] Supervisory fuzzy control of a base-isolated benchmark building utilizing a neuro-fuzzy model of controllable fluid viscous dampers
    Reigles, Damon G.
    Symans, Michael D.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 724 - 747
  • [7] Semiactive control of a base isolated building using magnetorheological dampers
    Zapateiro, Mauricio
    Luo, Ningsu
    Karimi, Hamid Reza
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2009, 7 (01) : 41 - 48
  • [8] A modified Kelvin impact model for pounding simulation of base-isolated building with adjacent structures
    Ye Kun
    Li Li
    Zhu Hongping
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2009, 8 (03) : 433 - 446
  • [9] Seismic performance of a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 777 - 793
  • [10] A modified Kelvin impact model for pounding simulation of base-isolated building with adjacent structures
    Kun Ye
    Li Li
    Hongping Zhu