Study of Variation in Intraocular Pressure Spike (IOP) Following Nd- YAG Laser Capsulotomy

被引:18
|
作者
Shetty, Niharika K. [1 ]
Sridhar, Sriya [1 ]
机构
[1] Sri Siddhartha Med Coll & Hosp, Dept Ophthalmol, Tumakuru, Karnataka, India
关键词
Acoustic shock; Capsulotomy; Elschenigs pearl; Glaucoma; Posterior capsular opacity; Pseudophakia;
D O I
10.7860/JCDR/2016/21981.9037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Posterior Capsular Opacifications (PCO) is a frequent complication of cataract surgery following posterior chamber intraocular lens implantation. Nd -Yag laser capsulotomy is the treatment of choice for PCO and is known to be associated with complications like Raised Intraocular Pressure (IOP), Intraocular lens pitting, intraocular lens cracks, cystoid macular oedema, retinal detachment, corneal burns. Raised IOP is the most common complication and prescribing anti-glaucoma drugs post capsulotomy is a common practise. Our study helps us to anticipate the post procedural IOP rise in specific patients and treat only selected group of patients with anti-glaucoma medications. Aim: To study and correlate the effect of energy used and number of shots with post procedural IOP spike following Nd-YAG laser capsulotomy cases. Materials and Methods: All patients with PCO presenting to Ophthalmology Out Patient Department at Sri Siddhartha Medical College between November 2014 to November 2015 were included. All the patients with glaucoma, uveitis and high myopia were excluded from the study. Data relevant to history, ocular examination and IOP were recorded. Results: Significant correlation of IOP spike with the number of Nd-YAG Laser shots delivered was found by One-way ANOVA Post-Hoc Tukeys Test. The p-value was significant for shots more than 40, provided the energy was restricted to 20 mJ and below. Correlation of energy with IOP spike was not significant as found by One-way ANOVA, Post-Hoc Tukey test. Predictability of 2 hours post-procedure IOP regarding persistent IOP rise was significant. Conclusion: It was observed that all pseudophakic patients may not require anti-glaucoma medication pre, or post Nd YAG laser capsulotomy. Only patients who required more than 40 shots during the procedure would need a close observation and if persistent rise is documented, ocular hypotensives may be advised.
引用
收藏
页码:NC9 / NC12
页数:4
相关论文
共 50 条
  • [41] Retrospective Study of Nd:YAG Capsulotomy Following Phacoemulsification
    Hegde, P.
    Ganesh, S.
    Brar, S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (44): : 3309 - 3313
  • [42] Comparison of the Incidence of Nd:YAG Laser Capsulotomy Based on the Type of Intraocular Lens
    Lee, Yuri
    Kim, Jae Suk
    Kim, Bum Gi
    Hwang, Je Hyung
    Kang, Min Ji
    Lee, Jee Hye
    MEDICINA-LITHUANIA, 2023, 59 (12):
  • [43] EFFECT OF PILOCARPINE IN TREATMENT OF INTRAOCULAR-PRESSURE ELEVATION FOLLOWING NEODYMIUM - YAG LASER POSTERIOR CAPSULOTOMY
    BROWN, SVL
    THOMAS, JV
    BELCHER, CD
    SIMMONS, RJ
    OPHTHALMOLOGY, 1985, 92 (03) : 354 - 359
  • [44] Use of Nd:YAG laser capsulotomy
    Aslam, TM
    Devlin, H
    Dhillon, B
    SURVEY OF OPHTHALMOLOGY, 2003, 48 (06) : 594 - 612
  • [45] YAG laser capsulotomy in multifocal intraocular lenses
    Ulrich Voigt
    Jürgen Strobel
    Der Ophthalmologe, 1999, 96 : 578 - 582
  • [46] Use of Nd:YAG laser capsulotomy
    Schubert, H
    SURVEY OF OPHTHALMOLOGY, 2004, 49 (03) : 376 - 377
  • [47] Intraocular pressure increase after Nd:YAG laser capsulotomy and anterior segment optical coherence tomography analysis
    Keles, Ali
    Karaman, Suleyman Korhan
    LASERS IN MEDICAL SCIENCE, 2023, 39 (01)
  • [48] YAG laser capsulotomy in multifocal intraocular lenses
    Voigt, U
    Strobel, J
    OPHTHALMOLOGE, 1999, 96 (09): : 578 - 582
  • [49] Effect of Nd:YAG laser posterior capsulotomy on intraocular pressure, refraction, anterior chamber depth, and macular thickness
    Parajuli, Anil
    Joshi, Purushottam
    Subedi, Prabha
    Pradhan, Chandni
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 945 - 952
  • [50] ND-YAG LASER POSTERIOR CAPSULOTOMY DOES NOT PRODUCE ELEVATION OF INTRAOCULAR-PRESSURE IN CYNOMOLGUS MONKEYS
    CAMRAS, CB
    ROSENTHAL, JS
    PODOS, SM
    OPHTHALMIC SURGERY AND LASERS, 1988, 19 (06): : 403 - 407