SIMULATION STUDIES OF BIOMAGNETIC COMPUTED-TOMOGRAPHY

被引:10
|
作者
RAMON, C
MEYER, MG
NELSON, AC
SPELMAN, FA
LAMPING, J
机构
[1] UNIV WASHINGTON,CTR IMAGING SYST OPTIMIZAT,SEATTLE,WA 98195
[2] UNIV WASHINGTON,REG PRIMATE RES CTR,SEATTLE,WA 98195
关键词
D O I
10.1109/10.222323
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reconstruction of planar and three-dimensional current distributions from measured biomagnetic signals is a new field of research, known as biomagnetic computed tomography. This noninvasive imaging technique promises to provide precise, millimeter-sized resolution images of the electrical currents in tissues or organs. We performed simulation studies on phantom models of electrical sources. As a first step towards the development of an imaging algorithm, we addressed a simplified problem to identify the shape and direction of current flow in a planar surface. The problem was formulated by identifying a space in which the image was to be reconstructed. The space was segmented into a grid. Each grid space represented a current element. The magnetic field at a sampling point due to the current elements was computed using the Biot-Savart law. Since there were many more current elements than sample points, the problem was underdetermined and had an uncountable number of solutions. The projection theorem was used to define an analytic solution for the magnitude and orientation of the current elements in the grid space. The solution required the inversion of large matrices in double precision. Such arrays were preprocessed on a mainframe computer, which permitted them to be rendered on any workstation. The accuracy of the image was determined by comparing it with the known location of the sources. Our results show that shape of the filamentary current flow can be imaged with our techniques. The resolution of images based on the sampling of the field, number of voxels in the reconstruction space, and noise is also analyzed.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [21] CORRELATIVE CRANIOSPINAL ANATOMY STUDIES BY COMPUTED-TOMOGRAPHY AND CRYOMICROTOMY
    RAUSCHNING, W
    BERGSTROM, K
    PECH, P
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) : 9 - 13
  • [22] STUDIES ON THE IMAGE QUALITY OF AN EMISSION COMPUTED-TOMOGRAPHY SYSTEM
    SCHULTZ, E
    THENEE, M
    KNOPP, R
    BIERSACK, HJ
    WINKLER, C
    BERGEDER, HD
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1982, 13 (01): : 28 - &
  • [23] COMPUTED-TOMOGRAPHY OF THE MEDIASTINUM
    VOCK, P
    TILLMANN, U
    FUCHS, WA
    RADIOLOGE, 1981, 21 (07): : 330 - 336
  • [24] COMPUTED-TOMOGRAPHY OF THE MEDIASTINUM
    SHEPARD, JAO
    CLINICS IN CHEST MEDICINE, 1984, 5 (02) : 291 - 305
  • [25] COMPUTED-TOMOGRAPHY OF THE NECK
    GAYLER, BW
    KASHIMA, HK
    MARTINEZ, CR
    CRC CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1985, 23 (04) : 319 - 412
  • [26] ABUSE OF COMPUTED-TOMOGRAPHY
    CALIN, A
    ARTHRITIS AND RHEUMATISM, 1982, 25 (09): : 1147 - 1148
  • [27] OVERVIEW OF COMPUTED-TOMOGRAPHY
    GOODENOUGH, DJ
    WEAVER, KE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 1661 - 1667
  • [28] THE FLOCCULUS IN COMPUTED-TOMOGRAPHY
    DANIELS, DL
    HAUGHTON, VM
    WILLIAMS, AL
    BERNS, TF
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1981, 2 (03) : 227 - 229
  • [29] COMPUTED-TOMOGRAPHY - APPLICATIONS
    FISHMAN, EK
    ACADEMIC RADIOLOGY, 1995, 2 : S141 - S142
  • [30] COMPUTED-TOMOGRAPHY OF THE MENISCI
    WAGNERMANSLAU, C
    RUPP, N
    PAAR, O
    RODAMMER, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 149 (04): : 392 - 395