ENERGY AND EXERGY ANALYSIS OF ABSORPTION-COMPRESSION CASCADE REFRIGERATION SYSTEM

被引:1
|
作者
Dixit, Manoj [1 ]
Kaushik, S. C. [1 ]
Arora, Akhilesh [2 ]
机构
[1] Indian Inst Technol Delhi, Ctr Energy Studies, Delhi, India
[2] Delhi Technol Univ, Dept Mech Engn, Delhi, India
来源
JOURNAL OF THERMAL ENGINEERING | 2016年 / 2卷 / 06期
关键词
absorption; compression; COP; exergy destruction; exergetic efficiency;
D O I
10.18186/jte.42367
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, an Absorption-Compression Cascade Refrigeration, comprising of a VCR system in low temperature stage and a VAR system at the high temperature stage, is analyzed. CO2, NH3 and R134a have been considered as refrigerants in the compression stage and the H2O-LiBr refrigerant absorbent pair in the absorption stage. The analysis has been realized by means of a mathematical model of the refrigeration system. The study presents the results obtained regarding the performance of the refrigeration system based on energy and exergy analysis. The comparative study helps to find out the best refrigerant and appropriate operation parameters. It is found in the study that cascade condenser, compressor and refrigerant throttle valve are the major source of exergy destruction.
引用
收藏
页码:995 / 1006
页数:12
相关论文
共 50 条
  • [31] Performance study on a low-temperature absorption-compression cascade refrigeration system driven by low-grade heat
    Xu, Yingjie
    Chen, Guangming
    Wang, Qin
    Han, Xiaohong
    Jiang, Ning
    Deng, Shiming
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 119 : 379 - 388
  • [32] Cascade refrigeration system synthesis based on exergy analysis
    Zhang, Jian
    Xu, Qiang
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (09) : 1901 - 1914
  • [33] Performance analysis of a solar based novel trigeneration system using cascaded vapor absorption-compression refrigeration system
    Khan, Yunis
    Mishra, R. S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 207 - 218
  • [34] Exergy analysis of a diffusion absorption refrigeration system
    Ben Jemaa, R.
    Ben Issa, N.
    Ben Issa, S.
    Bellagi, A.
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2008, 5 (5-6) : 626 - 637
  • [35] Comparative exergy and energy analyses of compression-absorption cascade refrigeration cycles with varied configurations and ejector implementations
    Bahrami, Hamid-Reza
    Fazli, Samane
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,
  • [36] Energy and exergy analyses of the diffusion absorption refrigeration system
    Yildiz, Abdullah
    Ersoz, Mustafa Ali
    [J]. ENERGY, 2013, 60 : 407 - 415
  • [37] Energy and exergy performance comparison of different configurations of an absorption-two-stage compression cascade refrigeration system with carbon dioxide refrigerant
    Mohammadi, S. M. Hojjat
    Ameri, Mehran
    [J]. APPLIED THERMAL ENGINEERING, 2016, 104 : 104 - 120
  • [38] Analysis of compression-absorption cascade refrigeration cycles
    Cimsit, Canan
    Ozturk, Ilhan Tekin
    [J]. APPLIED THERMAL ENGINEERING, 2012, 40 : 311 - 317
  • [39] A review on exergy analysis of vapor compression refrigeration system
    Ahamed, J. U.
    Saidur, R.
    Masjuki, H. H.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03): : 1593 - 1600
  • [40] ENERGY AND EXERGY ANALYSIS OF A VAPOR ABSORPTION REFRIGERATION SYSTEM IN AN INTERCITY BUS APPLICATION
    Kurtulmus, N.
    Bilgili, M.
    Sahin, B.
    [J]. JOURNAL OF THERMAL ENGINEERING, 2019, 5 (04): : 355 - 371