GINGIVAL CREVICULAR BLOOD FOR ASSESSMENT OF BLOOD-GLUCOSE IN DIABETIC-PATIENTS

被引:29
|
作者
PARKER, RC
RAPLEY, JW
ISLEY, W
SPENCER, P
KILLOY, WJ
机构
[1] UNIV MISSOURI,SCH DENT,DEPT PERIODONT,650 E 25TH ST,KANSAS CITY,MO 64108
[2] TRUMAN MED CTR,DEPT MED,KANSAS CITY,MO
[3] UNIV MISSOURI,SCH DENT,DEPT ORAL BIOL,KANSAS CITY,MO 64108
关键词
GINGIVAL CREVICULAR FLUID ANALYSIS; BLOOD GLUCOSE ANALYSIS; DIABETES-MELLITUS;
D O I
10.1902/jop.1993.64.7.666
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
IN THIS STUDY 50 PATIENTs with diabetes mellitus had gingival crevicular blood from periodontal probing collected in small plastic pipettes. The pipettes transferred the crevicular blood to a non-wipe glucose self-monitoring instrument. At the same time, finger-stick capillary blood measurements were analyzed in the same glucose self-monitoring instrument, and venous blood was collected for measurement in a laboratory glucose analyzer. Each laboratory measurement was corrected from a serum glucose value to a whole blood glucose value by a function of the patient's hematocrit. This corrected glucose value allowed direct comparison of the laboratory measurement to the intraoral and finger-stick whole blood measurements. The patient blood glucose concentrations ranged from 59 mg/dl to 366 mg/dl. The gingival crevicular blood exhibited a correlation of r = 0.975 (P <.0001) to the corrected laboratory standard measurement, with a mean prediction error (bias) of -4.11 mg/dl and a root mean square error (precision) of 17.43 mg/dl. The finger-stick blood had a correlation of r = 0.983 (P <.0001) to the corrected laboratory standard, with a mean prediction error of 4.65 mg/dl and a root mean square error of 14.48 mg/dl. The American Diabetic Association recommends that the prediction error of blood glucose monitoring devices fall within 15% of the laboratory standard. Using this criterion 92% of the gingival crevicular measurements and 90% of the finger-puncture measurements fell within 15% of the laboratory value. The results suggest that gingival crevicular blood collected by a small plastic pipette and measured in a non-wipe glucose self-monitor is feasible for in-office blood glucose testing with measurements comparable to those obtained using the finger-puncture method.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 50 条
  • [41] VISUAL FUNCTION, BLOOD-PRESSURE AND BLOOD-GLUCOSE IN DIABETIC-PATIENTS UNDERGOING CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS
    ROTTEMBOURG, J
    BELLIO, P
    MAIGA, K
    REMAOUN, M
    ROUSSELIE, F
    LEGRAIN, M
    PROCEEDINGS OF THE EUROPEAN DIALYSIS AND TRANSPLANT ASSOCIATION, 1985, 21 : 330 - 334
  • [42] METHOD FOR COMPREHENSIVE DESCRIPTION OF THE DEGREE AND QUALITY OF BLOOD-GLUCOSE CONTROL IN DIABETIC-PATIENTS AND NORMAL SUBJECTS
    SESTOFT, L
    VOLUND, A
    DIABETOLOGIA, 1982, 23 (02) : 201 - 201
  • [43] 5 YEAR AUDIT OF PERIPARTUM BLOOD-GLUCOSE CONTROL IN TYPE-1 DIABETIC-PATIENTS
    NJENGA, E
    LIND, T
    TAYLOR, R
    DIABETIC MEDICINE, 1992, 9 (06) : 567 - 570
  • [44] BLOOD-GLUCOSE, AGE AND GLOMERULAR-FILTRATION RATE IN INSULIN-DEPENDENT DIABETIC-PATIENTS
    WISEMAN, MJ
    VIBERTI, GC
    KEEN, H
    DIABETES, 1983, 32 : A16 - A16
  • [45] LACTULOSE IMPROVES BLOOD-GLUCOSE RESPONSE TO AN ORAL GLUCOSE TEST IN NON-INSULIN-DEPENDENT DIABETIC-PATIENTS
    GENOVESE, S
    RICCARDI, G
    RIVELLESE, AA
    DIABETES NUTRITION & METABOLISM, 1992, 5 (04) : 295 - 297
  • [46] BLOOD-GLUCOSE DETERMINATION IN DIABETIC HEMODIALYSIS-PATIENTS
    FRANKENBURG, CA
    HASBARGEN, JA
    ROUDEBUSH, RL
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 577 - 577
  • [47] Detection of blood glucose level through gingival crevicular blood - A pilot study
    Datta, Spiti
    Devaraj, C. G.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2015, 3 (01): : 69 - 72
  • [48] BLOOD-GLUCOSE AND DIABETIC-RETINOPATHY
    OROSZ, L
    UDVARDY, M
    FEHER, A
    VINCZE, P
    MADACSY, L
    BRITISH MEDICAL JOURNAL, 1992, 304 (6836): : 1244 - 1245
  • [49] BLOOD-GLUCOSE CONTROL AND DIABETIC COMPLICATIONS
    VANDERMERWE, CF
    ANNALS OF INTERNAL MEDICINE, 1987, 106 (02) : 331 - 331
  • [50] SELF-MONITORED BLOOD-GLUCOSE - ESSENTIAL BIOFEEDBACK SIGNAL IN THE DIABETIC-PATIENTS EFFORT TO ACHIEVE NORMOGLYCEMIA
    IRSIGLER, K
    BALITAUBALD, C
    DIABETES CARE, 1980, 3 (01) : 163 - 170