APPLICATION OF AN AUTOMATED PLASMA FILTRATION DEVICE AND A BLOOD MONITORING-SYSTEM FOR LDL APHERESIS

被引:0
|
作者
TABORSKI, U [1 ]
KOHLER, T [1 ]
SCHUPPHAUS, S [1 ]
HOFMANN, MR [1 ]
MULLERBERGHAUS, G [1 ]
机构
[1] KERCKHOFF KLIN,DEPT HEMOSTASEOL & TRANSFUS MED,W-6350 BAD NAUHEIM,GERMANY
来源
关键词
AUTOMATED PLASMAPHERESIS; PLASMA FILTRATION; PLASMA SEPARATION; IMMUNOGLOBULINS; BLOOD CELL COUNTS; LDL APHERESIS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study describes the adaptation of a filtration separation device (AK 10 from Gambro, Munchen, FRG) and a blood monitor system (BTS 100 from Diamed, Koln, FRG) to the automated adsorption/desorption device for LDL apheresis. Plasma separation by filtration was performed by a hollow-fiber filter (OP5, Asahi Corp., Japan). In order to evaluate the quality of the plasma obtained by filtration, the platelet contamination, the activity of factors V and VIII and the concentration of the immunoglobulins IgG and IgM were determined. The following results were found: Platelet contamination of the plasma was 2,740/mul. As compared to the patient's pretreatment values, activity of factor V was 94%, activity of factor VIII was 104%, concentration of IgG was 96%, concentration of IgM was 94%. Ten LDL aphereses were evaluated: red cell counts, platelet counts, hemoglobin concentration and hematocrit were not changed significantly. Thus, this new combination system represents an improved alternative to previously performed centrifugation methods.
引用
收藏
页码:187 / 189
页数:3
相关论文
共 50 条
  • [41] THE EVALUATION OF A NEW INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM IN THE PIG
    CLUTTONBROCK, TH
    FINK, S
    MARKLE, D
    LUTHRA, AJ
    HENDRY, SP
    [J]. JOURNAL OF CLINICAL MONITORING, 1994, 10 (06): : 387 - 391
  • [42] MULTISITE EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM
    LARSON, CP
    VENDER, J
    SEIVER, A
    [J]. ANESTHESIOLOGY, 1994, 81 (03) : 543 - 552
  • [43] THE NEED FOR A NATIONAL BLOOD PRODUCT MONITORING-SYSTEM - ROLE OF HEMOPHILIA REGISTRIES
    VANAKEN, WG
    [J]. TRANSFUSION, 1995, 35 (07) : 540 - 541
  • [44] APPLICATION OF PREDICTION EQUATIONS IN A WHOLE-BODY COUNTER MONITORING-SYSTEM
    ROESSLER, GS
    ZIPPER, T
    DUNAVANT, BG
    [J]. HEALTH PHYSICS, 1974, 27 (06): : 620 - 620
  • [45] PLASMA MATURE AND FURIN-CLEAVED PCSK9S ARE REMOVED BY LDL APHERESIS TREATMENT WITH BOTH LDL ADSORPTION AND DOUBLE MEMBRANE FILTRATION
    Hori, M.
    Yuasa, Y.
    Makino, H.
    Komai, H.
    Yanagi, K.
    Koezuka, R.
    Tamanaha, T.
    Kishimoto, I.
    Hattori, H.
    Harada-Shiba, M.
    [J]. ATHEROSCLEROSIS, 2014, 235 (02) : E74 - E75
  • [46] APPLICATION OF KALMAN FILTER TO AUTOMATIC MONITORING-SYSTEM OF MICROBIAL PHYSIOLOGICAL ACTIVITIES
    ENDO, I
    NAGAMUNE, T
    INOUE, I
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 413 (DEC) : 228 - 230
  • [47] REALTIME MEASUREMENT OF STROKE VOLUME - AN ADAPTIVE MONITORING-SYSTEM AND ITS APPLICATION
    GRASENICK, K
    BRINEK, A
    MARESCH, H
    PFURTSCHELLER, G
    WACH, P
    KOTANKO, P
    SKRABAL, F
    [J]. BIOMEDIZINISCHE TECHNIK, 1995, 40 (1-2): : 14 - 18
  • [48] APPLICATION OF MINIMAX PRINCIPLE TO DESIGN OF REACTOR IN-CORE MONITORING-SYSTEM
    KOBAYASHI, Y
    OKABE, K
    KONDO, S
    TOGO, Y
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1973, 10 (12) : 731 - 738
  • [49] ENTIRELY AUTOMATED GLUCOSE MONITORING-SYSTEM BASED ON A FLOW-INJECTION ANALYSIS APPARATUS
    PILLOTON, R
    MIGNOGNA, G
    FORTUNATO, A
    [J]. ANALYTICAL LETTERS, 1994, 27 (05) : 833 - 848
  • [50] Use of an automated device for alternative site blood glucose monitoring
    Fineberg, SE
    Bergenstal, RM
    Bernstein, RM
    Laffel, LM
    Schwartz, SL
    [J]. DIABETES CARE, 2001, 24 (07) : 1217 - 1220