THE TIBIOFIBULAR SYNDESMOSIS - EVALUATION OF THE LIGAMENTOUS STRUCTURE, METHODS OF FIXATION, AND RADIOGRAPHIC ASSESSMENT

被引:273
|
作者
XENOS, JS [1 ]
HOPKINSON, WJ [1 ]
MULLIGAN, ME [1 ]
OLSON, EJ [1 ]
POPOVIC, NA [1 ]
机构
[1] WALTER REED ARMY MED CTR, DEPT RADIOL, DIAGNOST RADIOL SERV, WASHINGTON, DC 20307 USA
来源
关键词
D O I
10.2106/00004623-199506000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty-five fresh-frozen cadaveric specimens were used to evaluate the role of the syndesmotic ligaments when the ankle is loaded with external rotation torque. An apparatus was constructed that allowed pure external-rotation torque to be applied through the ankle with the foot in neutral flexion. The apparatus provided solid fixation of the tibia while allowing free movement of the fibula in all planes. The syndesmotic ligaments were incrementally sectioned, and direct measurements of anatomical diastasis were made. Mortise and lateral radiographs were made at each increment under both loaded (5.0 newton-meters) and unloaded conditions. After all structures of the syndesmosis had been divided, the syndesmosis was reduced and was repaired with one or two screws. The strength of the repair was measured with incremental increases in torque of 1.0 newton-meter. The radiographs were measured by three independent observers in a blind fashion. In order to evaluate intraobserver error, each observer was randomly given forty radiographs to reinterpret. Diastasis and rotation were found to be related to the amount of injury of the ligament (p < 0.0001). After the entire syndesmosis had been divided, application of a 5.0-newton-meter torque resulted in a mean diastasis of 7.3 millimeters. The subsequent repair of the anterior tibiofibular ligament with suture failed at a mean of 2.0 newton-meters (range, 1.0 to 6.0 newton-meters) of torque. Repair with two screws was found to be stronger than repair with one, with the first construct failing at a mean of 11.0 newton-meters (range, 5.0 to 15.0 newton-meters) and the second, at a mean of 6.2 newton-meters (range, 2.0 to 10.0 newton-meters) (p = 0.0005). Failure of the screw fixation was not associated with the maximum previous diastasis (p = 0.13). Measurements of anatomical diastasis were compared with measurements made on the mortise and lateral radiographs. Measurements on the stress mortise radiographs had a weak correlation with diastasis (r = 0.41, p < 0.0001). However, measurements on the stress lateral radiographs had a higher correlation (r = 0.81, p < 0.0001). Additionally, interobserver correlation was significantly higher for the measurements on the lateral radiographs (r = 0.87, p < 0.0001) than for those on the mortise radiographs (r = 0.56, p < 0.0001). Intraobserver correlation for the three observers was poor with regard to the measurements on the mortise radiographs (r = 0.12, 0.42, and 0.25). The respective correlations for the measurements on the lateral radiographs were r = 0.81, 0.90, and 0.89. CLINICAL RELEVANCE: Diastasis of the distal aspects of the tibia and fibula on application of external rotation torque is related to the degree of injury to the syndesmosis. Also, the mechanical strength of fixation with two screws is superior to that of fixation with one screw and to that of suture repair of the anterior tibiofibular ligament. Assessment of the disruption of the syndesmosis on stress lateral radiographs has a much higher correlation with anatomical diastasis than does that on stress mortise radiographs. Furthermore, the stress lateral radiograph appears to be more reliable for the assessment of the syndesmosis.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [31] A reliable radiographic measurement for evaluation of normal distal tibiofibular syndesmosis: a multi-detector computed tomography study in adults
    Chen, Yanxi
    Qiang, Minfei
    Zhang, Kun
    Li, Haobo
    Dai, Hao
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2015, 8
  • [32] A reliable radiographic measurement for evaluation of normal distal tibiofibular syndesmosis: a multi-detector computed tomography study in adults
    Yanxi Chen
    Minfei Qiang
    Kun Zhang
    Haobo Li
    Hao Dai
    Journal of Foot and Ankle Research, 8
  • [33] A novel method of using elastic bionic fixation device for distal tibiofibular syndesmosis injury
    Lin Wang
    Yingze Zhang
    Zhaohui Song
    Hengrui Chang
    Ye Tian
    Fei Zhang
    International Orthopaedics, 2018, 42 : 2219 - 2229
  • [34] A novel method of using elastic bionic fixation device for distal tibiofibular syndesmosis injury
    Wang, Lin
    Zhang, Yingze
    Song, Zhaohui
    Chang, Hengrui
    Tian, Ye
    Zhang, Fei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (09) : 2219 - 2229
  • [35] The Effect of Varying Tension of a Suture Button Construct in Fixation of the Tibiofibular Syndesmosis-Evaluation Using Stress Computed Tomography
    Morellato, John
    Louati, Hakim
    Bodrogi, Andrew
    Stewart, Andrew
    Papp, Steven
    Liew, Allan
    Gofton, Wade
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (02) : 103 - 110
  • [36] Dunking the Knot in Suture Button Fixation for Distal Tibiofibular Syndesmosis Injury: Technique Tip
    Watson, Dylan J.
    Weatherby, Brian A.
    Womack, John W.
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (08) : 686 - 688
  • [37] The Tibiofibular Line: A Reliable Method of Syndesmosis Assessment in Certain Fibula Morphologies
    Pollizzi, Anthony A.
    Monir, Joseph G.
    Lagrew, Mollie
    Reb, Christopher
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [38] Radiographic assessment of ligamentous injuries in distal radius fractures after open reduction and internal fixation
    Naran S.
    Zaulan Y.
    Shakir S.
    Gilula L.A.
    Werner F.W.
    Wollstein R.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (7) : 1151 - 1154
  • [39] A Modified Technique for Fixation of Chronic Instability of the Distal Tibiofibular Syndesmosis Using a Wire and Button
    Xie, Bing
    Jing, Yan-feng
    Xiang, Liang-bi
    Zhou, Da-peng
    Tian, Jing
    JOURNAL OF FOOT & ANKLE SURGERY, 2014, 53 (06): : 813 - 816
  • [40] Titanium cable isotonic annular fixation system for the treatment of distal tibiofibular syndesmosis injury
    Jia, Zhaofeng
    Cheng, Jiwu
    Zhong, Haiyan
    Xiao, Tinghui
    Ren, Jinke
    Lin, Yimiao
    Huang, Wenjun
    Liang, Yujie
    Liu, Qisong
    Zhang, Xiaoming
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (08): : 4967 - 4975