THE TIBIOFIBULAR SYNDESMOSIS - EVALUATION OF THE LIGAMENTOUS STRUCTURE, METHODS OF FIXATION, AND RADIOGRAPHIC ASSESSMENT

被引:273
|
作者
XENOS, JS [1 ]
HOPKINSON, WJ [1 ]
MULLIGAN, ME [1 ]
OLSON, EJ [1 ]
POPOVIC, NA [1 ]
机构
[1] WALTER REED ARMY MED CTR, DEPT RADIOL, DIAGNOST RADIOL SERV, WASHINGTON, DC 20307 USA
来源
关键词
D O I
10.2106/00004623-199506000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty-five fresh-frozen cadaveric specimens were used to evaluate the role of the syndesmotic ligaments when the ankle is loaded with external rotation torque. An apparatus was constructed that allowed pure external-rotation torque to be applied through the ankle with the foot in neutral flexion. The apparatus provided solid fixation of the tibia while allowing free movement of the fibula in all planes. The syndesmotic ligaments were incrementally sectioned, and direct measurements of anatomical diastasis were made. Mortise and lateral radiographs were made at each increment under both loaded (5.0 newton-meters) and unloaded conditions. After all structures of the syndesmosis had been divided, the syndesmosis was reduced and was repaired with one or two screws. The strength of the repair was measured with incremental increases in torque of 1.0 newton-meter. The radiographs were measured by three independent observers in a blind fashion. In order to evaluate intraobserver error, each observer was randomly given forty radiographs to reinterpret. Diastasis and rotation were found to be related to the amount of injury of the ligament (p < 0.0001). After the entire syndesmosis had been divided, application of a 5.0-newton-meter torque resulted in a mean diastasis of 7.3 millimeters. The subsequent repair of the anterior tibiofibular ligament with suture failed at a mean of 2.0 newton-meters (range, 1.0 to 6.0 newton-meters) of torque. Repair with two screws was found to be stronger than repair with one, with the first construct failing at a mean of 11.0 newton-meters (range, 5.0 to 15.0 newton-meters) and the second, at a mean of 6.2 newton-meters (range, 2.0 to 10.0 newton-meters) (p = 0.0005). Failure of the screw fixation was not associated with the maximum previous diastasis (p = 0.13). Measurements of anatomical diastasis were compared with measurements made on the mortise and lateral radiographs. Measurements on the stress mortise radiographs had a weak correlation with diastasis (r = 0.41, p < 0.0001). However, measurements on the stress lateral radiographs had a higher correlation (r = 0.81, p < 0.0001). Additionally, interobserver correlation was significantly higher for the measurements on the lateral radiographs (r = 0.87, p < 0.0001) than for those on the mortise radiographs (r = 0.56, p < 0.0001). Intraobserver correlation for the three observers was poor with regard to the measurements on the mortise radiographs (r = 0.12, 0.42, and 0.25). The respective correlations for the measurements on the lateral radiographs were r = 0.81, 0.90, and 0.89. CLINICAL RELEVANCE: Diastasis of the distal aspects of the tibia and fibula on application of external rotation torque is related to the degree of injury to the syndesmosis. Also, the mechanical strength of fixation with two screws is superior to that of fixation with one screw and to that of suture repair of the anterior tibiofibular ligament. Assessment of the disruption of the syndesmosis on stress lateral radiographs has a much higher correlation with anatomical diastasis than does that on stress mortise radiographs. Furthermore, the stress lateral radiograph appears to be more reliable for the assessment of the syndesmosis.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [1] LIGAMENTOUS INJURY OF THE LOWER TIBIOFIBULAR SYNDESMOSIS - RADIOGRAPHIC EVIDENCE
    SCLAFANI, SJA
    RADIOLOGY, 1985, 156 (01) : 21 - 27
  • [2] A RADIOGRAPHIC EVALUATION OF THE TIBIOFIBULAR SYNDESMOSIS
    HARPER, MC
    KELLER, TS
    FOOT & ANKLE, 1989, 10 (03): : 156 - 160
  • [3] Radiographic Assessment of Tibiofibular Syndesmosis Injury with Different Durations and Types of Fixation
    Klepacki, Krzysztof
    Kowal, Igor
    Konieczny, Grzegorz
    Tomczyk, Lukasz
    Miekisiak, Grzegorz
    Morasiewicz, Piotr
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [4] The effects of rotation on radiographic evaluation of the tibiofibular syndesmosis
    Pneumaticos, SG
    Noble, PC
    Chatziioannou, SN
    Trevino, SG
    FOOT & ANKLE INTERNATIONAL, 2002, 23 (02) : 107 - 111
  • [5] Radiographic Evaluation of the Normal Distal Tibiofibular Syndesmosis
    Shah, Apurva S.
    Kadakia, Anish R.
    Tan, Giselle J.
    Karadsheh, Mark S.
    Wolter, Troy D.
    Sabb, Brian
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (10) : 870 - 876
  • [6] Biomechanical Analysis of Tibiofibular Syndesmosis Injury Fixation Methods: A Finite Element Analysis
    Mercan, Numan
    Yildirim, Ahmet
    Dere, Yunus
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (01): : 107 - 114
  • [7] Radiographic appearance of the normal distal tibiofibular syndesmosis in children
    Bozic, KJ
    Jaramillo, D
    DiCanzio, J
    Zurakowski, D
    Kasser, JR
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1999, 19 (01) : 14 - 21
  • [8] Weight-Bearing Radiographic Analysis of the Tibiofibular Syndesmosis
    Amin, Arsalan
    Janney, Cory
    Sheu, Christopher
    Jupiter, Daniel C.
    Panchbhavi, Vinod K.
    FOOT & ANKLE SPECIALIST, 2019, 12 (03) : 211 - 217
  • [9] Evaluation and management of injuries of the tibiofibular syndesmosis
    Magan, Ahmed
    Golano, Pau
    Maffulli, Nicola
    Khanduja, Vikas
    BRITISH MEDICAL BULLETIN, 2014, 111 (01) : 101 - 115
  • [10] Comparison of Different Fixation Methods of the Suture-Button Implant for Tibiofibular Syndesmosis Injuries
    Teramoto, Atsushi
    Suzuki, Daisuke
    Kamiya, Tomoaki
    Chikenji, Takako
    Watanabe, Kota
    Yamashita, Toshihiko
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10): : 2226 - 2232