摘要
The aim of this article was the control of disinfection in selected meat processing-plant by two methods - swabbing method and The 3M (TM) Petrifilm (TM) plates. Samples were collected within three months (September, October, November 2014). Together 54 samples selected surfaces were collected. Each month six samples were collected using imprint method with Petrifilm plates on total count of microorganisms, 6 samples using imprint method with Petrifilm plates on the number of coliforms and 6 samples using sterile swab method. Samples were collected from the workbench, conveyor belt, cutting blades, meat grinder, wall and knife. Total viable counts (TVC) and coliform bacteria (CB) were determined in samples. The values of TVC in September obtained by swabbing method were higher than allowable limit in sample no. 1 (3.70x10(2) CFU.cm(-2)) and in sample no. 4 (3.35x10(1) KTJ.cm(-2)). The values of TVC obtained by Petrifilm plates were lower than 10 CFU.cm(-2) in all samples. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm(-2) in all samples, CB obtained by swabbing method was 1.6x10(1) CFU.cm(-2) in sample no. 6. Values of TVC obtained in October by Petrifilm plates and also by swabbing method were higher than permissible limit (< 10 CFU.cm(-2)) in sample no. 2 and sample no. 4. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm(-2) in all samples, CB obtained by swabbing method was 3,65x10(1) CFU.cm(-2) in sample no. 3, value of CB obtained by swab method in sample no. 3 does not meet requirements of internal company standards. Values of TVC obtained in November by Petrifilm plates were lower than 10 CFU.cm(-2) in all samples. TVC otained by swab method were 1,25x10(1) CFU.cm(-2) in sample no. 3 and 3,25x10(1) CFU.cm(-2) in sample no. 4. Samples were not in accordance with requirements of internal company standards. Values of CB obtained in November by Petrifilm plates and by swabbing method were after disinfection lower than 1 CFU.cm(-2) in all samples.
引用
收藏
页码:564 / 567
页数:4
相关论文
共 50 条
  • [21] Disinfection of recycled red-meat-processing wastewater by ozone
    Wu, JN
    Doan, H
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2005, 80 (07) : 828 - 833
  • [22] CLEANING AND DISINFECTION OF SLAUGHTER-HOUSES AND MEAT PROCESSING FACTORIES
    SCHMIDT, U
    FLEISCHWIRTSCHAFT, 1982, 62 (04): : 427 - 434
  • [23] EVALUATION OF PORK MEAT FOR PROCESSING
    PERILLO, G
    INDUSTRIE ALIMENTARI, 1983, 22 (03): : 161 - 164
  • [24] Evaluation of donor skin disinfection methods
    Goldman, M
    Roy, G
    Frechette, N
    Decary, F
    Massicotte, L
    Delage, G
    TRANSFUSION, 1997, 37 (03) : 309 - 312
  • [25] CLEANING AND DISINFECTION IN SLAUGHTER-HOUSES AND MEAT-PROCESSING PLANTS
    SCHMIDT, U
    DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT, 1982, 89 (05): : 200 - 201
  • [26] Effectiveness of Alternate Methods of Toothbrush Disinfection: A Systematic Review
    Chellappa, Lalitha Rani
    Prabakar, Jayashri
    Indiran, Meignana Arumugham
    Kumar, Pradeep R.
    Doraikanan, Srisakthi
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (01): : 260 - 266
  • [27] Effectiveness of Alternative Methods for Toothbrush Disinfection: An In Vitro Study
    Peker, Ilkay
    Akca, Gulcin
    Sarikir, Cigdem
    Alkurt, Meryem Toraman
    Celik, Irem
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [28] The failure on the effectiveness of formalin on cadaver disinfection and alternative methods
    Yanilmaz, Ozgur
    Guncu, Mehmet Mucahit
    Aksu, Mehmet Burak
    Ozkan, Mazhar
    Sehirli, Umit Suleyman
    MARMARA MEDICAL JOURNAL, 2023, 36 (01): : 14 - 17
  • [29] Two different methods of cleaning and disinfection of endoscopy study of terminal disinfection
    Li, Yan-Ming
    Lu, Yi-An
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ADVANCED ENGINEERING MATERIALS AND TECHNOLOGY, 2015, 38 : 725 - 728
  • [30] Evaluation of toothbrush disinfection via different methods
    Basman, Adil
    Peker, Ilkay
    Akca, Gulcin
    Alkurt, Meryem Toraman
    Sarikir, Cigdem
    Celik, Irem
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):