EVALUATION OF THE DISINFECTION EFFECTIVENESS AT MEAT PROCESSING BY THE TWO METHODS

被引:2
|
作者
Kunova, Simona [1 ]
Kacaniova, Miroslava [2 ]
Hascik, Peter [3 ]
Cubon, Juraj [3 ]
Lopasovsky, Lubomir [1 ]
Kluz, Maciej [4 ]
机构
[1] Slovak Univ Agr, Fac Biotechnol & Food Sci, Dept Food Hyg & Safety, Tr A Hlinku 2, Nitra 94976, Slovakia
[2] Slovak Univ Agr, Fac Biotechnol & Food Sci, Dept Microbiol, Nitra 94976, Slovakia
[3] Slovak Univ Agr, Fac Biotechnol & Food Sci, Dept Anim Prod Evaluat & Proc, Nitra 94976, Slovakia
[4] Univ Rzeszow, Dept Biotechnol & Microbiol, Fac Biol & Agr, PL-35601 Rzeszow, Poland
关键词
disinfection; total viable count; coliform bacteria; Petrifilm plates; swabbing method;
D O I
10.15414/jmbfs.2015.4.6.564-567
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The aim of this article was the control of disinfection in selected meat processing-plant by two methods - swabbing method and The 3M (TM) Petrifilm (TM) plates. Samples were collected within three months (September, October, November 2014). Together 54 samples selected surfaces were collected. Each month six samples were collected using imprint method with Petrifilm plates on total count of microorganisms, 6 samples using imprint method with Petrifilm plates on the number of coliforms and 6 samples using sterile swab method. Samples were collected from the workbench, conveyor belt, cutting blades, meat grinder, wall and knife. Total viable counts (TVC) and coliform bacteria (CB) were determined in samples. The values of TVC in September obtained by swabbing method were higher than allowable limit in sample no. 1 (3.70x10(2) CFU.cm(-2)) and in sample no. 4 (3.35x10(1) KTJ.cm(-2)). The values of TVC obtained by Petrifilm plates were lower than 10 CFU.cm(-2) in all samples. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm(-2) in all samples, CB obtained by swabbing method was 1.6x10(1) CFU.cm(-2) in sample no. 6. Values of TVC obtained in October by Petrifilm plates and also by swabbing method were higher than permissible limit (< 10 CFU.cm(-2)) in sample no. 2 and sample no. 4. Values of CB obtained by Petrifilm plates were lower than 1 CFU.cm(-2) in all samples, CB obtained by swabbing method was 3,65x10(1) CFU.cm(-2) in sample no. 3, value of CB obtained by swab method in sample no. 3 does not meet requirements of internal company standards. Values of TVC obtained in November by Petrifilm plates were lower than 10 CFU.cm(-2) in all samples. TVC otained by swab method were 1,25x10(1) CFU.cm(-2) in sample no. 3 and 3,25x10(1) CFU.cm(-2) in sample no. 4. Samples were not in accordance with requirements of internal company standards. Values of CB obtained in November by Petrifilm plates and by swabbing method were after disinfection lower than 1 CFU.cm(-2) in all samples.
引用
收藏
页码:564 / 567
页数:4
相关论文
共 50 条
  • [1] THE ECONOMICS OF CLEANING AND DISINFECTION METHODS IN THE MEAT PROCESSING-INDUSTRY
    SCHOLZ, SR
    ORTH, R
    MULLER, HJ
    FLEISCHWIRTSCHAFT, 1989, 69 (06): : 972 - 976
  • [2] Effectiveness of clinical surface cleaning and disinfection: evaluation methods
    Frota, Oleci Pereira
    Ferreira, Adriano Menis
    Rigotti, Marcelo Alessandro
    de Andrade, Denise
    Amaral Borges, Najla Moreira
    Ferreira Junior, Marcos Antonio
    REVISTA BRASILEIRA DE ENFERMAGEM, 2020, 73 (01)
  • [3] Evaluation of Consumer Acceptability of Meat Processing Methods
    Lu, T.
    Wall, P.
    Burke, M.
    McCaffrey, N.
    Scannell, A. G. M.
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2017, 76 (OCE3) : E68 - E68
  • [4] Preoperative disinfection of foot and ankle: microbiological evaluation of two disinfection methods
    Siem A. Dingemans
    Ingrid J. B. Spijkerman
    Merel F. N. Birnie
    J. Carel Goslings
    Tim Schepers
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1389 - 1394
  • [5] Preoperative disinfection of foot and ankle: microbiological evaluation of two disinfection methods
    Dingemans, Siem A.
    Spijkerman, Ingrid J. B.
    Birnie, Merel F. N.
    Goslings, J. Carel
    Schepers, Tim
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (10) : 1389 - 1394
  • [6] Biofilm and disinfection in meat processing plants
    Jessen, B
    Lammert, L
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2003, 51 (04) : 265 - 269
  • [7] DISINFECTION IN SLAUGHTERHOUSE AND MEAT PROCESSING FACTORY
    HEUSCHER, E
    CASAGRANDE, F
    FLEISCHWIRTSCHAFT, 1977, 57 (03): : 401 - 405
  • [8] THE EFFECTIVENESS OF CLEANING AND DISINFECTION DURING MEAT PRODUCTION AND PROCESSING - INFLUENCE FACTORS AND USE RECOMMENDATIONS
    REUTER, G
    FLEISCHWIRTSCHAFT, 1994, 74 (08): : 808 - 813
  • [9] Evaluation of the effectiveness of current disinfection methods in complete denture patients
    Degirmenci, Beyza Unalan
    Kakai, Ribaz Tahsin Hayas
    Guducuoglu, Huseyin
    Ozcan, Mutlu
    QUINTESSENCE INTERNATIONAL, 2022, 53 (01): : 36 - 46
  • [10] Efficacy of knife disinfection techniques in meat processing
    Leps, J.
    Einschuetz, K.
    Langkabel, N.
    Fries, R.
    MEAT SCIENCE, 2013, 95 (02) : 185 - 189