VALIDATION OF A RADIOASSAY FOR THE DETERMINATION OF SERUM FOLATE AND COBALAMIN CONCENTRATIONS IN DOGS

被引:14
|
作者
BATT, RM [1 ]
MCLEAN, L [1 ]
RUTGERS, HC [1 ]
HALL, EJ [1 ]
机构
[1] UNIV LIVERPOOL,DEPT VET PATHOL,LIVERPOOL L69 3BX,ENGLAND
关键词
D O I
10.1111/j.1748-5827.1991.tb00552.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Determinations of serum folate and cobalamin concentrations in dogs have proved of considerable value for the identification and characterisation of chronic small intestinal disorders, but the microbiological assays used are time-consuming and technically demanding. Dual isotope radioassays are more convenient and have been developed for the determination of folate and cobalamin in human beings. This study has evaluated such an assay for the determination of serum folate and cobalamin concentrations in dogs by direct comparison with microbiological assays used previously. Assays were performed on samples from 77 dogs, including controls and animals with confirmed or suspected chronic small intestinal disease. Regression analysis demonstrated a significant relationship between the two assays for serum folate concentrations (R = 0.85; P = 0.0001) and a definite trend for radioassay to give lower results than bioassay. There was also a significant relationship between bioassay and radioassay data for serum cobalamin (R = 0.91; P = 0.0001) with comparable absolute values for these two assays. Radioassay of serum samples from 31 clinically healthy dogs gave control ranges of 3.7 to 8.8-mu-g/litre for folate and 205 to 490 ng/litre for cobalamin. These ranges were similar to those calculated by comparison with the established ranges for bioassay using regression analysis, which predicted ranges of 4.4 to 8.4-mu-g/litre and 217 to 398 ng/litre for radioassay of serum folate and cobalamin, respectively. These data indicate that a dual isotope radioassay of serum folate and cobalamin may be used for dogs, and emphasise the need for laboratories to validate and establish their own control ranges for different assays.
引用
收藏
页码:221 / 224
页数:4
相关论文
共 50 条
  • [1] THE EFFECT OF THE OXIDATION-STATE OF THE FOLATE STANDARD ON THE RESULTS OF THE SIMULTANEOUS RADIOASSAY OF SERUM FOLATE AND COBALAMIN
    LINDEMANS, J
    VANKAPEL, J
    CLINICA CHIMICA ACTA, 1981, 114 (2-3) : 315 - 320
  • [2] Analytic validation of commercially available immunoassays for the measurement of serum cobalamin and folate concentrations in pigs
    Grutzner, Niels
    Knabe, Darrel
    Lawhorn, Bruce D.
    Dominguez, Brandon
    Kauffold, Johannes
    Suchodolski, Jan S.
    Steiner, Jorg M.
    VETERINARY CLINICAL PATHOLOGY, 2016, 45 (02) : 311 - 319
  • [4] RADIOASSAY OF SERUM FOLATE
    DUNN, RT
    FOSTER, LB
    CLINICAL CHEMISTRY, 1973, 19 (10) : 1101 - 1105
  • [5] Effect of Enterococcus faecium SF68 on serum cobalamin and folate concentrations in healthy dogs
    Lucena, R.
    Olmedilla, A. B.
    Blanco, B.
    Novales, M.
    Ginel, P. J.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2018, 59 (07) : 438 - 443
  • [6] Are serum folate and cobalamin concentrations valid for evaluating small-intestinal disorders in dogs? Commentary
    Davies, C
    VETERINARY MEDICINE, 1998, 93 (10) : 905 - 906
  • [8] EFFECT OF CYANIDE ON RADIOASSAY FOR SERUM COBALAMIN
    ROTHENBERG, SP
    LAWSON, J
    CLINICAL CHEMISTRY, 1979, 25 (04) : 639 - 640
  • [9] Influence of age on serum cobalamin and folate concentrations in healthy cats
    Parnell, N. K.
    Moore, G. E.
    Suchodolski, J. S.
    Steiner, J. M.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (03) : 809 - 809
  • [10] SERUM THIAMIN, PYRIDOXAL, COBALAMIN AND FOLATE CONCENTRATIONS IN YOUNG INFANTS
    DAVIS, RE
    ICKE, GC
    HILTON, JM
    ORR, E
    ACTA PAEDIATRICA SCANDINAVICA, 1986, 75 (03): : 402 - 407