MICRO ELECTRON-CAPTURE DETECTOR FOR TEMPERATURE PROGRAMMED ANALYSIS WITH CAPILLARY COLUMNS FOR A WIDE-RANGE OF APPLICATIONS

被引:12
|
作者
BRECHBUHLER, B
GAY, L
JAEGER, H
机构
[1] BRECHBUHLER AG,CH-8902 URDORF,SWITZERLAND
[2] STADT LAB,PESTICIDABT,CH-8031 ZURICH,SWITZERLAND
[3] UNIV ULM,INST STOFFWECHSEL & ERNAHRUNGSWISSENSCH,D-7900 ULM,FED REP GER
关键词
D O I
10.1007/BF02257363
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:478 / 486
页数:9
相关论文
共 50 条
  • [31] GAS-CHROMATOGRAPHIC DETERMINATION OF PHENOLS AS 2,4-DINITROPHENYL ETHERS USING GLASS-CAPILLARY COLUMNS AND AN ELECTRON-CAPTURE DETECTOR
    LEHTONEN, M
    JOURNAL OF CHROMATOGRAPHY, 1980, 202 (03): : 413 - 421
  • [32] TEMPERATURE PROGRAMMED ANALYSIS OF ESSENTIAL OILS USING GLASS CAPILLARY COLUMNS
    KUGLER, E
    LANGLAIS, R
    HALANG, W
    HUFSCHMIDT, M
    CHROMATOGRAPHIA, 1975, 8 (09) : 468 - 473
  • [33] Resolving power of pixel detector Timepix for wide-range electron, proton and ion detection
    Granja, Carlos
    Jakubek, Jan
    Polansky, Stepan
    Zach, Vaclav
    Krist, Pavel
    Chvatil, David
    Stursa, Jan
    Sommer, Marek
    Ploc, Ondrej
    Kodaira, Satoshi
    Martisikova, Maria
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 60 - 71
  • [34] RELATIVE ELECTRON-CAPTURE DETECTOR RESPONSE OF SELECTED POLYCHLORINATED BIPHENYL CONGENERS INFLUENCE OF DETECTOR TEMPERATURE AND DESIGN
    CIGANEK, M
    DRESSLER, M
    LANG, V
    JOURNAL OF CHROMATOGRAPHY A, 1994, 668 (02) : 441 - 448
  • [35] ANALYSIS OF ORGANOCHLORINE PESTICIDE-RESIDUES USING SIMULTANEOUS INJECTION OF 2 CAPILLARY COLUMNS WITH ELECTRON-CAPTURE AND ELECTROLYTIC CONDUCTIVITY DETECTORS
    HOPPER, ML
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1991, 74 (06): : 974 - 981
  • [36] AN ELECTRON-BEAM LITHOGRAPHY TOOL WITH A SCHOTTKY EMITTER FOR WIDE-RANGE APPLICATIONS
    KOEK, BH
    CHISHOLM, T
    VONRUN, AJ
    ROMIJN, J
    DAVEY, JP
    MICROELECTRONIC ENGINEERING, 1994, 23 (1-4) : 81 - 84
  • [37] ELECTRON-CAPTURE GAS-CHROMATOGRAPHY OF SULFONAMIDES - EFFECTS OF STRUCTURE AND TEMPERATURE ON DETECTOR RESPONSE
    GYLLENHAAL, O
    HARTVIG, P
    JOURNAL OF CHROMATOGRAPHY, 1980, 189 (03): : 351 - 357
  • [38] PRACTICAL REMARKS ABOUT APPLICATION OF ELECTRON-CAPTURE DETECTOR IN CHROMATOGRAPHIC TRACE ANALYSIS
    LASA, J
    ROSIEK, J
    KORUS, A
    CHEMIA ANALITYCZNA, 1977, 22 (04): : 779 - 785
  • [39] DETERMINATION OF AMINO-ACIDS BY MEANS OF GLASS-CAPILLARY GAS-LIQUID-CHROMATOGRAPHY WITH TEMPERATURE-PROGRAMMED ELECTRON-CAPTURE DETECTION
    CHAUHAN, J
    DARBRE, A
    JOURNAL OF CHROMATOGRAPHY, 1982, 236 (01): : 151 - 156
  • [40] Prediction of the separation number of capillary columns in programmed temperature gas chromatographic analysis
    Vezzani, S.
    Moretti, P.
    Castello, G.
    ANALYTICA CHIMICA ACTA, 2007, 599 (01) : 151 - 161