GLOBAL AND REGIONAL DETECTION OF INDUCED OPTIC DISC CHANGE BY DIGITIZED IMAGE-ANALYSIS

被引:29
|
作者
BURGOYNE, CF
VARMA, R
QUIGLEY, HA
VITALE, S
PEASE, ME
LENANE, PL
机构
[1] JOHNS HOPKINS SCH MED,WILMER OPHTHALMOL INST,GLAUCOMA SERV,BALTIMORE,MD
[2] JOHNS HOPKINS SCH MED,WILMER OPHTHALMOL INST,DANA CTR PREVENT OPHTHALMOL,BALTIMORE,MD
关键词
D O I
10.1001/archopht.1994.01090140137035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate two new strategies for the detection of optic disc change within individual eyes by digitized image analysis. Methods: Eleven normal optic discs of 11 monkeys were imaged with a digital imaging system (Topcon Imagenet, Topcon Instrument Corporation of America, Paramus, NJ) at two intraocular pressures (10 and 45 mm Hg). To detect global change in the disc, we compared conventional optic disc parameters with a new optic disc parameter: mean position of the disc. To detect regional change, the 95% confidence interval for change was calculated for each data point and mapped for each disc. Results: Posterior deformation of the disc surface was detected in seven of 11 eyes using conventional parameters and in 10 of 11 eyes using mean position of the disc. Regions of posterior deformation were detected by 95% confidence interval for change mapping in all 11 discs as localized areas of confluent, posteriorly displaced points. Conclusions: Mean position of the disc outperformed conventional measurements in the detection of global optic disc change. Ninety-five percent confidence interval for change mapping may allow individual data point-based focal and regional analysis of the disc.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [21] COMPUTERIZED IMAGE-ANALYSIS OF THE OPTIC-NERVE HEAD IN NEUROOPHTHALMOLOGY
    WALSH, T
    CAPRIOLI, J
    NEURO-OPHTHALMOLOGY, 1987, 7 (03) : 139 - 146
  • [22] COMPUTERIZED IMAGE-ANALYSIS OF THE OPTIC DISK - DIRECT VS INDIRECT IMAGE ACQUISITION
    LYONS, JL
    CANTOR, LB
    MANATUNGA, AK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 882 - 882
  • [23] Tumor detection in digitized mammograms by image texture analysis
    Pfisterer, R
    Aghdasi, F
    OPTICAL ENGINEERING, 2001, 40 (02) : 209 - 216
  • [24] DETECTION OF ACTIVITY-INDUCED CHROMOSOMAL-ABERRATIONS USING IMAGE-ANALYSIS
    ITO, S
    SUMITOMO, H
    MATSUOKA, Y
    WATER SCIENCE AND TECHNOLOGY, 1992, 25 (11) : 227 - 234
  • [25] Global Vessel Symmetry for Optic Disc Detection in Retinal Images
    Panda, Rashmi
    Puhan, N. B.
    Panda, G.
    2015 FIFTH NATIONAL CONFERENCE ON COMPUTER VISION, PATTERN RECOGNITION, IMAGE PROCESSING AND GRAPHICS (NCVPRIPG), 2015,
  • [26] SUBPIXEL DETECTION IN VIDEO RHEED IMAGE-ANALYSIS
    MATOLIN, V
    PEUCHOT, B
    THIN SOLID FILMS, 1995, 259 (01) : 65 - 69
  • [27] MODIFIED VORONOI DIAGRAM AND RELATIVE NEIGHBORS ON A DIGITIZED PICTURE AND THEIR APPLICATIONS TO TISSUE IMAGE-ANALYSIS
    TORIWAKI, J
    MASE, K
    YASHIMA, Y
    FUKUMURA, T
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 375 : 362 - 367
  • [28] DETECTION OF BACTERIA IN SOLID FOODS BY IMAGE-ANALYSIS
    FERNANDES, MA
    CLARK, SA
    JACKMAN, PJH
    JOURNAL OF APPLIED BACTERIOLOGY, 1987, 63 (06): : R2 - R3
  • [29] RetCam image analysis of the optic disc in premature infants
    Park, J. W.
    Park, S. W.
    Heo, H.
    EYE, 2013, 27 (10) : 1137 - 1141
  • [30] RetCam image analysis of the optic disc in premature infants
    J W Park
    S W Park
    H Heo
    Eye, 2013, 27 : 1137 - 1141