DIRECT MEASUREMENT OF INTRACELLULAR PRESSURE

被引:29
|
作者
KELLY, SM [1 ]
MACKLEM, PT [1 ]
机构
[1] ROYAL VICTORIA HOSP,MONTREAL H3A 1A1,QUEBEC,CANADA
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1991年 / 260卷 / 03期
关键词
CELL MECHANICS; MICROPRESSURE; OSMOTIC SWELLING; XENOPUS-LAEVIS OOCYTES;
D O I
10.1152/ajpcell.1991.260.3.C652
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The feasibility of using the servo-null technique for direct measurement of intracellular pressure (P(in)) was investigated. A large cell, the Xenopus laevis oocyte, was chosen for study, and it was established that P(in) obtained with this method was both stable and accurate in these cells. Median resting P(in) in oocytes was found to be 0.27 cmH2O, range 0.14-0.61 cmH2O. During osmotic swelling P(in) increased, in a nonlinear fashion, to a value of 4.11 cmH2O, range 2.61-8.91 cmH2O, with increases in cell volume (V(c)) of 24 +/- 3% (SE). This technique may be of use in the study of cellular mechanics.
引用
收藏
页码:C652 / C657
页数:6
相关论文
共 50 条
  • [21] Direct measurement of intracranial pressure in adult horses
    Brosnan, RJ
    LeCouteur, RA
    Steffey, EP
    Imai, A
    Kortz, GD
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2002, 63 (09) : 1252 - 1256
  • [22] DIRECT MEASUREMENT OF INTRACRANIAL PRESSURE AFTER OPERATION
    MARKAKIS, E
    BUES, E
    SPRING, A
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1970, 33 (05): : 715 - &
  • [23] Frequency response of direct pressure measurement systems
    Bentley, M.W.
    Lee, C.M.
    Australasian Physical and Engineering Sciences in Medicine, 1988, 11 (04): : 150 - 155
  • [24] DIRECT MEASUREMENT OF THE STRUCTURAL COMPONENT OF THE DISJOINING PRESSURE
    DERYAGIN, BV
    RABINOVICH, YI
    CHURAEV, NV
    BULLETIN OF THE ACADEMY OF SCIENCES OF THE USSR DIVISION OF CHEMICAL SCIENCE, 1982, 31 (08): : 1548 - 1553
  • [25] ENDONEURIAL FLUID PRESSURE - DIRECT MEASUREMENT WITH MICROPIPETS
    MYERS, RR
    POWELL, HC
    COSTELLO, ML
    LAMPERT, PW
    ZWEIFACH, BW
    BRAIN RESEARCH, 1978, 148 (02) : 510 - 515
  • [26] OPHTHALMODYNAMOMETRIC AND DIRECT MEASUREMENT OF OPHTHALMIC ARTERY PRESSURE
    BORRAS, A
    MARTINEZ, A
    MENDEZ, MS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 67 (05) : 681 - &
  • [27] A SIMPLE METHOD FOR DIRECT ARTERIAL PRESSURE MEASUREMENT
    COOPERMA.LH
    MANN, PEG
    ANESTHESIOLOGY, 1966, 27 (01) : 93 - +
  • [28] SIMULTANEOUS DUAL MEASUREMENT OF INTRACELLULAR PRESSURE IN CHAOS-CAROLINENSIS
    YANAI, M
    KENYON, CM
    MACKLEM, PT
    FASEB JOURNAL, 1993, 7 (03): : A242 - A242
  • [29] The direct measurement of intracellular pigments in phytoplankton using resonance Raman spectroscopy
    Barletta, Robert E.
    Krause, Jeffrey W.
    Goodie, Taylor
    El Sabae, Hijrah
    MARINE CHEMISTRY, 2015, 176 : 164 - 173
  • [30] DIRECT MEASUREMENT OF INTRACELLULAR PH IN RAT AND CRAB MUSCLE IN-VITRO
    PAILLARD, M
    SRAER, JD
    LEVIEL, F
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1971, 1 (05) : 387 - &