Pulmonary artery pseudoaneurysm after Swan-Ganz catheterization: a case presentation and review of literature

被引:20
|
作者
Nellaiyappan, Madhan [1 ]
Omar, Hesham R. [2 ]
Justiz, Rafael [3 ]
Sprenker, Collin [1 ]
Camporesi, Enrico M.
Mangar, Devanand [1 ,4 ,5 ]
机构
[1] Florida Gulf Bay Anesthesiol, Tampa, FL USA
[2] Mercy Med Ctr, Internal Med Dept, 1410 N 4th St, Clinton, IA 52732 USA
[3] Oklahoma Pain Phys, Oklahoma City, OK USA
[4] Tampa Gen Hosp, Dept Anesthesia, Tampa, FL 33606 USA
[5] Tampa Gen Hosp, Florida Gulf Bay Anesthesiol Associates, Tampa, FL 33606 USA
关键词
Pulmonary artery pseudoaneurysm; pulmonary artery rupture; pulmonary artery injury; Swan-Ganz catheter; right heart catheterization;
D O I
10.1177/2048872613520252
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The Swan-Ganz catheter for pulmonary artery (PA) cannulation was introduced in 1970 and has been utilized in the management of critically ill and cardiac patients. Although the routine use of this catheter has not been associated with better patient outcomes in prospective randomized trials, their ability to provide crucial hemodynamic measurements and the ease of bedside insertion makes them valuable in certain complex clinical scenarios. However, Swan-Ganz catheter insertion is not without complications. PA injury is the most serious complication suspected by the occurrence of hemoptysis after the procedure. We present a case of PA injury with pseudoaneurysm formation after Swan-Ganz catheterization along with a comprehensive review of literature. Methods: We reviewed all PubMed/Medline indexed articles published between 1993-2013, reporting the development of PA pseudoaneurysm after Swan-Ganz catheter use. Cases were analyzed with specific reference to patient demographics, indication for Swan-Ganz insertion, initial presenting symptom, duration between insertion and first evidence of PA injury, inciting event, site of pseudoaneurysm, treatment and outcome. Results: Forty-one patients were identified from 27 papers. In the reviewed population, 87.8% were older than 60 years of age and 82.9% were females. Fifty-one percent of the patients had an episode of hemoptysis on the day of Swan-Ganz catheter insertion. Ninety-seven percent of the patients had PA pseudoaneurysm in the right pulmonary circulation. The admission-to-discharge mortality rate in the reviewed cohort was 15%. Cause of death in 22% of the cases was hemoptysis, while non-catheter related complications were responsible for the remaining deaths. Conclusion: PA injury is a feared complication after Swan-Ganz catheterization and can be fatal. In patients who develop massive or recurrent hemoptysis after Swan-Ganz catheter use, PA injury must be considered and airway protection should be employed along with appropriate catheter based or surgical interventions.
引用
收藏
页码:281 / 288
页数:8
相关论文
共 50 条
  • [31] Value of multislice CT in the diagnosis of pulmonary artery pseudoaneurysm from Swan-Ganz catheter placement
    Kierse, R
    Jensen, U
    Heimberger, H
    Muth, G
    Rieber, A
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (10) : 1133 - 1137
  • [32] INTERNAL JUGULAR VEIN FUNCTION AFTER SWAN-GANZ CATHETERIZATION
    PERKINS, NAK
    CAIL, WS
    BEDFORD, RF
    ELINGER, JH
    BUSCHI, AJ
    ANESTHESIOLOGY, 1984, 61 (04) : 456 - 459
  • [33] A CLUE TO PULMONARY-EMBOLISM OBTAINED DURING SWAN-GANZ CATHETERIZATION
    LEWIS, JF
    ANDERSON, TW
    FENNELL, WH
    YOUNG, JB
    CHEST, 1982, 81 (04) : 527 - 527
  • [34] THROMBOCYTOPENIA ASSOCIATED WITH SWAN-GANZ CATHETERIZATION IN PATIENTS
    KIM, YL
    RICHMAN, KA
    MARSHALL, BE
    ANESTHESIOLOGY, 1980, 53 (03) : 261 - 262
  • [35] Sucssful interventional treatment of a large pulmonary artery aneurysm after Swan-Ganz
    Brandes, H
    Albes, JM
    ANNALS OF THORACIC SURGERY, 2003, 75 (02): : 639 - 639
  • [36] HORNERS SYNDROME SECONDARY TO SWAN-GANZ CATHETERIZATION
    TEICH, SA
    HALPRIN, SL
    TAY, S
    AMERICAN JOURNAL OF MEDICINE, 1985, 78 (01): : 168 - 170
  • [37] ARTERY PULMONARY PERFORATION INDUCED BY A SWAN-GANZ CATHETER - REPORT OF ONE CASE
    BRASSEUR, P
    SUKKARIEH, F
    DUPONT, H
    JOURNAL DE RADIOLOGIE, 1994, 75 (04): : 241 - 243
  • [38] Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient -a case report-
    Sugiyama, Daisuke
    Ikeno, Shigeo
    Tsuchihashi, Tetsuya
    Yokota, Shigeru
    Ina, Hiroaki
    Kono, Tetsuya
    Yamashita, Kunihiko
    Kawamata, Mikito
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2014, 67 (05) : 346 - 349
  • [39] SWAN-GANZ CATHETERIZATION IN THE CRITICALLY ILL NEWBORN
    TODRES, ID
    CRONE, RK
    ROGERS, MC
    SHANNON, DC
    CRITICAL CARE MEDICINE, 1979, 7 (08) : 330 - 334
  • [40] SWAN-GANZ CATHETER - REVIEW
    HATHAWAY, R