DETERMINATION OF AMIDEPIN IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:1
|
作者
STEHLIK, P
HOUBOVA, H
机构
[1] Research Institute for Pharmacy and Biochemistry, 130 60 Prague 3
来源
关键词
D O I
10.1016/0378-4347(91)80413-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An isocratic reversed-phase high-performance liquid chromatographic method for the determination of amidepin has been developed. The method is based on the extraction of alkaline plasma with diethyl ether-dichloromethane, and the injection into the Supelcosil LC-18 column of the evaporated and reconstituted organic phase. After separation, detection is carried out by a fluorescence detector (excitation at 195 nm with no filter). The limit of detection is 10 ng/ml of plasma. The mean coefficient of variation is 12%. The plasma levels after oral administration and after intravenous administration are shown.
引用
下载
收藏
页码:477 / 481
页数:5
相关论文
共 50 条
  • [1] DETERMINATION OF MEPAMIL IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    STEHLIK, P
    HOUBOVA, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 529 (01): : 251 - 257
  • [2] DETERMINATION OF OXIRACETAM IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUOROMETRIC DETECTION
    SIMPSON, RC
    BOPPANA, VK
    HWANG, BYH
    RHODES, GR
    JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2): : 227 - 232
  • [3] DETERMINATION OF TETRACYCLINE ANTIBIOTICS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    IWAKI, K
    OKUMURA, N
    YAMAZAKI, M
    JOURNAL OF CHROMATOGRAPHY, 1992, 623 (01): : 153 - 158
  • [4] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHOSPHOLIPIDS WITH FLUORESCENCE DETECTION
    ABIDI, SL
    MOUNTS, TL
    RENNICK, KA
    JOURNAL OF CHROMATOGRAPHY, 1993, 639 (02): : 175 - 184
  • [5] DETERMINATION OF PLASMA OXALATE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEREZ, E
    REVISTA ESPANOLA DE FISIOLOGIA, 1986, 42 (04): : 441 - 447
  • [6] THE DETERMINATION OF BROMAZEPAM IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LESOLLEU, H
    DEMOTESMAINARD, F
    VINCON, G
    BANNWARTH, B
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) : 771 - 775
  • [7] DETERMINATION OF VIGABATRIN IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TSANACLIS, LM
    WICKS, J
    WILLIAMS, J
    RICHENS, A
    THERAPEUTIC DRUG MONITORING, 1991, 13 (03) : 251 - 253
  • [8] DETERMINATION OF ANTIPYRINE IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CAMPBELL, TM
    MURDAUGH, EW
    KILLENBERG, PG
    JOURNAL OF CHROMATOGRAPHY, 1979, 163 (02): : 236 - 238
  • [9] DETERMINATION OF KETANSERIN IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAVIES, CL
    JOURNAL OF CHROMATOGRAPHY, 1983, 275 (01): : 232 - 233
  • [10] DETERMINATION OF QUERCETIN IN HUMAN PLASMA USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIU, B
    ANDERSON, D
    FERRY, DR
    SEYMOUR, LW
    DETAKATS, PG
    KERR, DJ
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01): : 149 - 155