STANDARD SPHENOIDAL AND MINI-SPHENOIDAL ELECTRODES - A DIRECT COMPARISON

被引:6
|
作者
BUCHHALTER, JR
SCHOMER, DL
SCHACHTER, SC
机构
[1] CHILDRENS HOSP MED CTR, DEPT NEUROL, BOSTON, MA 02115 USA
[2] BETH ISRAEL HOSP, DEPT NEUROL, BOSTON, MA 02215 USA
来源
JOURNAL OF EPILEPSY | 1991年 / 4卷 / 01期
关键词
EPILEPSY; SPHENOIDAL ELECTRODES; MINI-SPHENOIDAL ELECTRODES;
D O I
10.1016/0896-6974(91)90119-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study was designed to directly compare EEG recordings from standard sphenoidal (SS) electrodes to those obtained from subdermal "mini-sphenoidal" (MSP) electrodes. A montage was designed to include SS electrodes, MSP electrodes, and surface temporal leads. In a series of 100 consecutive patients, 9 cases demonstrated abnormalities in the SS and MSP electrodes only. An additional 6 patients had abnormalities present only in the SS electrodes. We conclude that MSP electrodes cannot be substituted for SS electrodes in the search for suspected abnormalities in temporal, inferior, or mesial brain regions.
引用
收藏
页码:29 / 31
页数:3
相关论文
共 50 条
  • [21] The localizing yield of sphenoidal and anterior temporal electrodes in ictal recordings: A comparison study
    Kanner, AM
    Parra, J
    Gil-Nagel, A
    Soto, A
    Leurgans, S
    Iriarte, J
    deToledo-Morrell, L
    Palac, S
    EPILEPSIA, 2002, 43 (10) : 1189 - 1196
  • [22] COMPARISON AND CORRELATION OF SURFACE AND SPHENOIDAL ELECTRODES WITH SIMULTANEOUS INTRACRANIAL RECORDING - AN INTERICTAL STUDY
    MARKS, DA
    KATZ, A
    BOOKE, J
    SPENCER, DD
    SPENCER, SS
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (01): : 23 - 29
  • [23] Comparison of sphenoidal, cheek and anterior temporal electrodes in mesial temporal lobe epilepsy
    Nayak, D.
    P, S.
    Radhakrishnan, K.
    EPILEPSIA, 2007, 48 : 98 - 98
  • [24] COMPARISON OF SPHENOIDAL, NASOPHARYNGEAL, AND SURFACE ELECTRODES IN EVALUATING PATIENTS WITH PARTIAL COMPLEX SEIZURES
    MARCUS, RW
    SO, E
    KING, DW
    GALLAGHER, BB
    EPILEPSIA, 1984, 25 (05) : 652 - 652
  • [25] IDENTIFICATION OF TEMPORAL EPILEPTIC SEIZURES BY PERCUTANEOUS SPHENOIDAL ELECTRODES
    GIROUD, M
    GRAS, P
    BEURIAT, P
    SOICHOT, P
    DUMAS, R
    PRESSE MEDICALE, 1990, 19 (25): : 1183 - 1187
  • [26] Precise placement of sphenoidal electrodes via fluoroscopic guidance
    Fenton, DS
    Geremia, GK
    Dowd, AM
    Papathanasiou, MA
    Greenlee, WM
    Huckman, MS
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (04) : 776 - 778
  • [28] Localization of mesial temporal lobe seizures with sphenoidal electrodes
    Pacia, SV
    Jung, WJ
    Devinsky, O
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1998, 15 (03) : 256 - 261
  • [29] DIAGNOSIS OF TEMPORAL SEIZURES IN CHILDHOOD - THE CONTRIBUTION OF SPHENOIDAL ELECTRODES
    SEPTIEN, L
    BOURGEOIS, M
    GIROUD, M
    NIVELON, JL
    DUMAS, R
    PEDIATRIE, 1991, 46 (02): : 193 - 200
  • [30] USE OF ACUPUNCTURE NEEDLES AS SPHENOIDAL ELECTRODES IN ELECTROENCEPHALOGRAPHY - REAPPRAISAL
    YINGKUN, F
    DANHUA, G
    CHINESE MEDICAL JOURNAL, 1979, 92 (06) : 371 - 378